Types Frog Leg & Wave Winding

Encyclopedia
Field: Encyclopedia
0
China

Frog Leg Winding Definition

A frog leg winding is a combination of a multiplex wave and a simplex lap winding in the same slots. It retains the advantages of both lap windings and wave windings without their inherent disadvantages.

Lap and wave windings each have an equal number of parallel paths, which are connected to the same commutator.

The frog-leg winding has as many parallel paths as duplex lap windings because the simplex lap winding portion supplies ‘P’ number of parallel paths and the multiplex-wave section also provides ‘P’ number of parallel paths. Hence the total is 2P number of paths in parallel (which is the same number as a duplex lap winding).

Advantages of Frog Leg Winding

This winding has more no. of parallel paths and the current and the voltage rating is higher than that of lap or wave winding. These frog-leg wound armatures are designed for the use with moderate current and moderate voltage.

These windings are connected in series-parallel. Any wave element and the succeeding lap element connected on the commutator exactly two pole pitches apart in a series combination. This two commutator segments are exactly 360 electrical degrees apart and develop zero net voltage. Therefore, this lap-wave combination of a frog leg winding is fully equalized and eliminates the use of an equalizer. That is why most large DC machines use frog-leg wound armatures.

Drum Winding Definition

This is the type of winding in which the conductors are placed in slots over the drum-shaped armature surface and connected to one another by front and back connections at coil ends. Drum winding is introduced mainly to overcome the shortcomings of ring-type winding.

Advantages of Drum Winding

Each winding, placed on the armature slots, surrounds the core and so that the entire length of the conductor, except the end connections, cut the main magnetic flux. Therefore the voltage induced in this type of armature winding is larger than the Gramme-ring winding.

The coils, before placing on the armature slots, can be pre-formed and insulated. Hence cost can be reduced.

The two sides of the coil placed under two different poles, one North Pole and another South Pole, hence the emf induced in them are always additive with the help of the end connection.

Fractional pitch winding can be used in drum winding. The advantage of fractional pitch winding is that it gives substantial savings in the copper of end connections. Commutation is also improved because of the lesser mutual inductor between the coils.

Fractional pitch winding: To get the maximum emf, the coil span should match the pole pitch. However, reducing the coil span to eight-tenths (8/10) of the pole pitch can still induce significant emf. This is called fractional-pitch winding.

Because of several conductors are placed in a single slot, the nos. of the slot get reduced in the armature core, the armature core teeth become mechanically stronger. The lamination and the protection of coils are also improved.

The manufacturing cost will be reduced in the drum type winding because here we have to construct fewer coils.

Gramme Ring Winding Definition

A ring winding is the type of armature winding in which the wire is wound around the outer and inner surfaces alternately of a cylindrical or ring-shaped core. The Gramme-ring type of armature winding is an old type of armature winding. In this winding, the armature consists of a hollow cylinder or ring made up of iron lamination. The core is wound with insulated wire spirally about the ring.

The winding is continuous, and hence it is closed. We connect the coils between brushes in series. The figure shows Gramme-Ring type winding and its equivalent circuit. We can see that there is an equal number of voltage-generating conductors placed on each side of the armature.

We tap the wire at regular intervals and connect them to the commutator segments. There are two paths between the positive and negative brushes, connected in parallel. Coils 1 to 6 form one path, while coils 7 to 12 form the other.

When the armature rotates in the clockwise direction, then the emf is induced in the conductors. The direction of induced emf and the direction of current will be inward in case of the conductors under N-pole by Fleming’s right-hand rule. In the case of the conductors under S-pole, the direction of induced emf and the direction of current will be outward.

820195080217cc56e87cf725d07f5674.jpeg

According to Fleming’s right-hand rule, hold your right hand with the thumb, forefinger, and middle finger at right angles. The forefinger shows the magnetic field direction, the thumb indicates motion, and the middle finger points to the induced current.

Thus the EMF generated in two paths are in the opposite direction as shown in the above figure. The emf generated on each path is additive from bottom to top on each side. Since there are two parallel paths, the voltage per path is the generated voltage of the machine, and each path provides half of the current output in the external circuit.

Advantages of Gramme Ring Winding

  • Operating principle of the armature is simpler because there is no crossing of conductors in the winding.

  • Same winding can be employed with 2, 4, 6 or 8 poles theoretically.

  • Disadvantages of Gramme Ring Winding

  • The part of this winding located on the inner side of the iron ring cut very few lines of flux. Thus they have very little voltage induced in them. For this reason, it is not widely used.

  • With the same no. of poles the same velocity of the armature winding the induced emf in Gramme-ring winding is half of the induced emf in the drum type winding.

  • As the portion lying inside the inner ring acts only as connectors so, there is a wastage of copper.

  • Repairs and maintenance are very costly.

  • Insulation of winding is much difficult.

  • Strong field excitation needed to produce the require flux because the construction requires a large air gap.

Give a tip and encourage the author!
Recommended
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.