Pang-Neutrong Klima na 24kV Switchgear para sa Sustainable na Grids | Nu1

Edwiin
Edwiin
Larangan: Pamindih ng kuryente
China

Inaasahang buhay ng serbisyo na 30-40 taon, front access, kompak na disenyo na katumbas ng SF6-GIS, walang handling ng gas ng SF6 – climate-friendly, 100% dry air insulation. Ang switchgear na Nu1 ay metal-enclosed, gas-insulated, may disenyo ng withdrawable circuit breaker, at nakapasa sa type-testing ayon sa mga pamantayan, na aprubado ng internationally recognized STL laboratory.

Pamantayan ng Pagtutugon

  • Switchgear: IEC 62271-1 High-voltage switchgear and controlgear – Part 1: Common specifications for alternating current switchgear and controlgear

  • IEC 62271-200 High-voltage switchgear and controlgear – Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV

  • Circuit Breaker: IEC 62271-100 High-voltage switchgear and controlgear – Part 100: Alternating current circuit breakers

  • Disconnector / Earthing Switch: IEC 62271-102 High-voltage switchgear and controlgear – Part 102: Alternating current disconnectors and earthing switches

  • Current Transformer (CT): IEC 61869-2 Instrument transformers – Part 2: Current transformers

  • Voltage Transformer (VT): IEC 61869-3 Instrument transformers – Part 3: Voltage transformers

  • Insulation: IEC 60071 Insulation coordination

  • IP Code: IEC 60529 Degrees of protection provided by enclosures (IP code)

  • IK Code: IEC 62262 Degrees of protection provided by enclosures against external mechanical impacts (IK code)

  • Voltage Detection System (VDS): IEC 62271-213 Voltage detecting systems for high-voltage switchgear and controlgear

  • Operation: EN 50110 Operation of electrical installations

  • Installation: IEC 61936-1 Power installations exceeding 1 kV AC

  • Environmental Conditions: IEC 60721-3-3 Classification of environmental conditions

NU1..jpg

Ratings ng Elektrikal

  • Rated Voltage (Ur): 24 / 36 kV

  • Power Frequency / Impulse Test Voltage (Ud/Up): 50/125 / 70/170 kV

  • Rated Frequency (fr): 50/60 Hz

  • Rated Busbar Current (Ir): 2500 A

  • Rated Feeder Current: 1250 / 2000 A

  • Rated Peak Withstand Current (Ip): 78.8 / 81.9 kA

  • Rated Short-Time Current (Ik): 31.5 kA / 3 s

  • Internal Arc Protection (AFLR): 31.5 kA / 1 s

  • Operating Temperature: -5 °C to +40 °C

Sukat

  • Width: 650 mm (1250 A), 900 mm (2000 A)

  • Height: 2400 mm

  • Depth: 1500 mm

Dry Air Insulation Medium

Filling Pressure at 20°C (relative): 200 kPa

Minimum Operating Pressure at 20°C (relative): 180 kPa

Gas Leakage Rate: < 0.1 %/year

Pressure Relief Disc Operating Pressure: ≥ 350 kPa (gauge)

Rated Operating Sequence: O – 0.3 s – CO – 15 s – CO

NU1..jpg

Ayon sa IEC 62271:

  • Circuit Breaker Durability Class (per IEC 62271-100): M2, E2, C2

  • Disconnector Durability Class (per IEC 62271-102): M0, E0

  • Sealed stainless-steel tank for enclosed switchgear.

  • Dry air insulation medium eliminates the need for SF6 gas handling.

  • Compact size equivalent to SF6-insulated switchgear.

  • External cone plug-in system for connecting power cables and solid-insulated busbars

  • No gas work required for installation, commissioning, or future modifications.

  • Integrated pressure relief duct system.

  • Equipped with sensors for real-time monitoring of switchgear operational status.

User-Friendly Features:

  • Compact design

  • Accessible control panel

  • No SF6 – safe and climate-friendly operation

  • Front access to switchgear

Accessibility:

  • Cable compartment, current transformers (CTs), and voltage transformers (VTs) accessible from the front of the switchgear.

  • Easy cable grounding via vacuum circuit breaker ensures safe operation.

  • Metal-coated VTs, shielding, and touch-safe cables and busbars enhance safety.

Insulation Medium:

Switchgear filled with dry air insulation gas.

Characteristics of dry air:

  • Non-toxic

  • No F-gases involved

  • Climate neutral

  • Non-flammable

  • Chemically neutral

Panel Design:

  • Factory-assembled and type-tested.

  • Single-pole, solid-insulated, shielded, plug-in busbars.

  • Maintenance-free.

  • Vacuum circuit breaker.

  • Three-position disconnector for disconnection and grounding via circuit breaker.

  • Protective grounding via vacuum circuit breaker.

  • Cable connection via external cone plug-in system according to DIN EN 50 181.

  • Instrument transformers can be replaced without gas handling.

Degree of protection:

  • IP65 for all high-voltage parts of the main circuit.

  • IP3X for the switchgear enclosure.

Modular Design:

  • Current and voltage transformers mounted externally for easy maintenance.

  • Voltage transformers are metal-coated, plug-in, and disconnectable.

  • Panel replacement requires no additional gas work or movement of adjacent panels.

  • Protection and measurement systems can be integrated.

  • Low-voltage compartment is removable; busbars and instrument transformers are plug-in

  • Optional: Digital multifunction protection relay with integrated protection, control, communication, operation, and monitoring functions.

Environmental Independence:
The Nu1 consists of switchgear enclosed in a sealed tank inside an outer enclosure. This protects high-voltage components from environmental influences such as:

Harsh environmental conditions

External parameters including:

  • Salt, dust

  • Humidity, corrosion

  • Insects, rodents

  • High installation altitudes

Maintenance-Free Design:

Nuventura switchgear is enclosed in a sealed, dry-air-insulated tank, providing maintenance-free operation over its service life, ensuring:

  • Safety of personnel

  • Reliable and uninterrupted power supply

  • Sealed pressure system designed for 30 years

  • Maintenance-free under environmental conditions

  • Reduced operational costs

Automation and Digitization:

Automation systems and relays ensure timely and conditional operation of the equipment, enabling:

  • Unidirectional automation and integration into central Supervisory Control and Data Acquisition (SCADA) systems.

  • Cost-effective and efficient equipment operation based on logic functions, offering flexible and integrated solutions.

Sensor Integration (Optional):

Sensor systems are integrated within the switchgear, enabling:

  • Real-time health monitoring

  • Continuous monitoring of gas temperature, partial discharge, quality, and density

  • Savings on scheduled maintenance costs

  • Early identification of potential failures before they occur

Magbigay ng tip at hikayatin ang may-akda!
Inirerekomenda
Mga Compact na Air-Insulated RMUs para sa Retrofit at Bagong Substations
Mga Compact na Air-Insulated RMUs para sa Retrofit at Bagong Substations
Ang mga air-insulated ring main units (RMUs) ay inilalarawan sa kabaligtaran ng mga compact gas-insulated RMUs. Ang mga unang air-insulated RMUs ay gumamit ng vacuum o puffer-type load switches mula sa VEI, pati na rin ang mga gas-generating load switches. Sa paglipas ng panahon, kasabay ng malawakang pag-adopt ng serye ng SM6, ito ay naging pangunahing solusyon para sa mga air-insulated RMUs. Tulad ng iba pang mga air-insulated RMUs, ang pangunahing pagkakaiba ay nasa pagsasalitla ng load switc
Echo
11/03/2025
Pagsasara sa Linya ng Busbar para sa 24kV Eco-Friendly RMUs: Bakit at Paano
Pagsasara sa Linya ng Busbar para sa 24kV Eco-Friendly RMUs: Bakit at Paano
Ang kombinasyon ng solid na insulasyon at dry air insulation ay isang direksyon ng pag-unlad para sa 24 kV ring main units. Sa pamamagitan ng pagbalanse ng kakayahan sa insulasyon at kompakto, ang paggamit ng solid auxiliary insulation ay nagpapahintulot na makatapos ng mga pagsusulit sa insulasyon nang hindi lubhang lumaking ang phase-to-phase o phase-to-ground dimensions. Ang encapsulation ng pole ay maaaring tugunan ang insulasyon ng vacuum interrupter at ang mga konektadong conductor.Para sa
Dyson
11/03/2025
Paano Ang Teknolohiya ng Buumang Paligid Nagpapalit ng SF6 sa Modernong Ring Main Units
Paano Ang Teknolohiya ng Buumang Paligid Nagpapalit ng SF6 sa Modernong Ring Main Units
Ang mga ring main units (RMUs) ay ginagamit sa secondary power distribution, na direkta nang nakakonekta sa mga end-users tulad ng residential communities, construction sites, commercial buildings, highways, at iba pa.Sa isang residential substation, ang RMU ay nagpapakilala ng 12 kV medium voltage, na pagkatapos ay binababa sa 380 V low voltage pamamaraan ng mga transformers. Ang low-voltage switchgear ay nagdidistribute ng electrical energy sa iba't ibang user units. Para sa isang 1250 kVA dis
James
11/03/2025
Bakit Nagbibigay ng Mga RMU? Pinag-uusapan ang Condensation & Gas Leak
Bakit Nagbibigay ng Mga RMU? Pinag-uusapan ang Condensation & Gas Leak
1. PagkakakilalaAng mga ring main units (RMUs) ay pangunahing kagamitan sa paghati ng enerhiya na naglalaman ng load switches at circuit breakers sa loob ng metal o hindi metal na enclosure. Dahil sa kanilang maliit na sukat, simple na estruktura, mahusay na insulasyon, mababang gastos, madaling pag-install, at buong siguradong disenyo [1], ang RMUs ay malawakang ginagamit sa medium- at low-voltage power systems sa grid network ng Tsina [2], lalo na sa 10 kV distribution systems. Sa patuloy na p
Felix Spark
10/31/2025
Inquiry
I-download
Kuha ang IEE Business Application
Gumamit ng IEE-Business app para makahanap ng kagamitan makakuha ng solusyon makipag-ugnayan sa mga eksperto at sumama sa industriyal na pakikipagtulungan kahit kailan at saanman buong suporta sa pag-unlad ng iyong mga proyekto at negosyo sa enerhiya