What is an ELCB?

Encyclopedia
Field: Encyclopedia
0
China


What is an ELCB?


ELCB Definition


An Earth-leakage circuit breaker (ELCB) is a safety device used in electrical installations (both residential and commercial) with high Earth impedance to prevent electric shocks. It detects small stray voltages on the metal enclosures of electrical equipment, and interrupts the circuit if a dangerous voltage is detected.


ELCBs help detect current leaks and insulation failures in the electrical circuits that would cause electrical shocks to anyone coming into contact with the circuit.There are two types of earth leakage circuit breakers—a voltage ELCB and a current ELCB.


Voltage ELCB


The working principle of a voltage ELCB is straightforward. One terminal of the relay coil connects to the equipment’s metal body, while the other terminal connects directly to the earth.


If insulation fails or a live wire touches the metal body, a voltage difference appears between the coil terminal and the earth. This difference causes current to flow through the relay coil.


e6cd083ab41410683d7ee4078fba558d.jpeg


If the voltage difference crosses, a predetermined limit, the current through the relay becomes sufficient to actuate the relay for tripping the associated circuit breaker to disconnect the power supply to the equipment.


The typicality of this device is, it can detect and protect only that equipment or installation with which it is attached. It cannot detect any leakage of insulation in other parts of the system. Study our Electrical MCQs to learn more about the operation of ELCBs.


Current ELCB (RCCB)


The working principle of current earth leakage circuit breaker or RCCB is also very simple as voltage operated ELCB but the theory is entirely different and residual current circuit breaker is more sensitive than ELCB.


ELCBs come in two types: voltage-based and current-based. Voltage-based ELCBs are often called simple ELCBs, while current-based ones are known as RCDs or RCCBs. In RCCBs, a current transformer (CT) core is energized by both phase and neutral wires.


7cd3dd40cfbcfdd84732015b269ea15d.jpeg


Single Phase Residual Current ELCB. The polarity of the phase winding and neutral winding on the core is so chosen that, in normal condition mmf of one winding opposes that of another.


As it is assumed that, in normal operating conditions the current goes through the phase wire will be returned via neutral wire if there’s no leakage in between.


As both currents are same, the resultant mmf produced by these two currents is also zero-ideally.The relay coil is connected with another third winding wound on the CT core as secondary. The terminals of this winding are connected to a relay system.


In normal operating condition there would not be any current circulating in the third winding as here is no flux in the core due to equal phase and neutral current.


When an earth leakage occurs, some of the phase current may pass to the earth through the leakage path instead of returning via the neutral wire.Hence the magnitude of the neutral current passing through the RCCB is not equal to phase current passing through it.


0f8a592ec3b018a7e30a1ff18a68b88d.jpeg


When the imbalance exceeds a set value, the current in the third winding becomes high enough to activate the electromagnetic relay.This relay causes tripping of the associated circuit breaker to disconnect the power supply to the equipment under protection.


Residual current circuit breaker is sometimes also referred as residual current device (RCD) when we consider the device by disassociating the circuit breaker attached to RCCB. That means, the entire parts of RCCB except circuit breaker are referred as RCD. 


Give a tip and encourage the author!
Recommended
What are the principles of forced re-energization of transmission lines?
Principles of Forced Re-energization of Transmission LinesRegulations for Forced Re-energization of Transmission Lines Correctly select the forced re-energization end of the line. If necessary, change the connection configuration before forced re-energization, taking into account the reduction of short-circuit capacity and its impact on grid stability. There must be a transformer with its neutral point directly grounded on the busbar at the forced re-energization end. Pay attention to the impact
Edwiin
09/04/2025
Analysis of Accident Handling in Transmission Lines
Analysis of Transmission Line Fault HandlingAs a fundamental component of the power grid, transmission lines are widely distributed and numerous, often exposed to diverse geographical and climatic conditions, making them highly susceptible to faults. Common causes include overvoltage, pollution flashover, insulation damage, tree encroachment, and external damage. Line tripping is one of the most frequent faults in power plant and substation operations, with fault types including single-phase-to-
Leon
09/04/2025
The difference between transmission and distribution lines
Transmission lines and distribution lines are both used to carry electrical power from one location to another. However, they differ significantly in key aspects such as primary function, voltage levels, phase configuration, and conductor placement. These differences are essential for understanding their distinct roles in the power system.The Difference Between Transmission and Distribution Line is given below in the tabulated form.Electricity generation is a critical component of the power syst
Edwiin
09/04/2025
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
Related Products
  • 7.2kV MV motor starter with vacuum contactor up to 7.2 kV
  • Compact High-Voltage Load Switch
  • 12kV SF6 insulated switchgear/power distribution ring main unit
  • Intelligent Electrical Solid Insulated Switchgear Cabinet/Ring Main Unit
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.