What is Voltage Controlled Oscillator?

Encyclopedia
Field: Encyclopedia
0
China


What is Voltage Controlled Oscillator?


Voltage Controlled Oscillator Definition


A voltage controlled oscillator (VCO) is defined as an oscillator whose output frequency is controlled by an input voltage.


Working Principle


VCO circuits can be designed by means of many voltage control electronic components such as varactor diodes, transistors, Op-amps etc. Here, we are going to discuss about the working of a VCO using Op-amps. The circuit diagram is shown below.


The output waveform of this VCO will be square wave. As we know the output frequency is related to the control voltage. In this circuit the first Op-amp will function as an integrator. The voltage divider arrangement is implemented here. 


Because of this, the half of the control voltage that is given as input is given to the positive terminal of the Op-amp 1. The same level of voltage is maintained at the negative terminal. This is to sustain the voltage drop across the resistor, R 1


ef39a6dfd6d6a05a5b8cfeb58ed926e1.jpeg

 

When the MOSFET is in on condition, the current flowing from the R1 resistor passes through the MOSFET. The R2 have half the resistance, same voltage drop and twice the current as that of R1. So, the extra current charges the connected capacitor. The Op-amp 1 should provide a gradually increasing output voltage to supply this current.


When the MOSFET is in off condition, the current flowing from the R1 resistor passes through the capacitor, get discharged. The output voltage obtained from the Op-amp 1 at this time will be falling. As a result, a triangular waveform is generated as the output of Op-amp 1.


The second Op-amp functions as a Schmitt trigger. It takes the triangular wave from the first Op-amp as input. If this input voltage exceeds the threshold level, the output of the second Op-amp will be VCC. If it is below the threshold, the output will be zero, resulting in a square wave output.


Example of VCO is LM566 IC or IC 566. It is in fact an 8 pin integrated circuit which can produce double outputs-square wave and triangular wave. The internal circuit is represented below.


a784b981237e2d66fc51ecc6da65993e.jpeg


Frequency Control in Voltage Controlled Oscillator


Many forms of VCOs are generally used. It can be of RC oscillator or multi vibrator type or LC or crystal oscillator type. However; if it is of RC oscillator type, the oscillation frequency of output signal will be in inversely proportional to capacitance as


5fcffaeadd1bbfd07c9c00e40d2b129a.jpeg

In the case of LC oscillator, the oscillation frequency of output signal will be


So, we can say that as the input voltage or control voltage increases, the capacitance get reduced. Hence, the control voltage and frequency of oscillations are directly proportional. That is, when one increases, the other will increase.


20a65aa89993da5f38f8ffc8c91f3d40.jpeg


The figure above represents the basic working of voltage controlled oscillator. Here, we can see that at nominal control voltage represented by VC(nom), the oscillator works at its free running or normal frequency, fC(nom). 


As the control voltage decreases from nominal voltage, the frequency also decreases and as the nominal control voltage increases, the frequency also gets higher.


Varactors diodes, which are variable capacitance diodes available in different ranges, are used to achieve variable voltage. In low-frequency oscillators, the charging rate of capacitors is changed using a voltage controlled current source.


Types of Voltage Controlled Oscillator


  • Harmonic Oscillators

  • Relaxation Oscillators


Applications


  • Function generator

  • Phase Locked Loop

  • Tone generator

  • Frequency-shift keying

  • Frequency modulation

Give a tip and encourage the author!

Recommended

Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Reclosing Charge Time: Why Does Reclosing Require Charging? What Effects Does Charging Time Have?
1. Function and Significance of Reclosing ChargingReclosing is a protective measure in power systems. After faults such as short circuits or circuit overloads occur, the system isolates the faulty circuit and then restores normal operation through reclosing. The function of reclosing is to ensure continuous operation of the power system, improving its reliability and safety.Before performing reclosing, the circuit breaker must be charged. For high-voltage circuit breakers, the charging time is g
12/15/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.