• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Oscillator Collector Harmonizatus

Encyclopedia
Campus: Encyclopaedia
0
China

Definitio Oscillatoris Collectoris Regulati


Oscillator collectivus regulatus definitur ut oscillator LC qui circuitum tank et transistorem ad generandum signum periodicum utitur.


Explicatio Diagrammatis Circuiti

 

56567440f5bf1518fd2a9c15833d6121.jpeg

 

Diagramma circuiti oscillator collectivum regulatum ostendit. Transformator et condensator ad collector transistri connecti sunt, sinusoidem producunt.


R1 et R2 dividerem tensionis pro transistor formant. Re resistorem emitter refert et est ad stabilitatem thermicam praebendam. Ce ad amplificatas oscillationes ac bypassandam utitur et est condensator bypass emitter. C2 est condensator bypass pro resistore R2. Primarius transformatoris, L1 cum condensatore C1 circuitum tank format.


Operatio Oscillatoris Collectoris Regulati


Antequam in operationem oscillatoris ingrediamur, revocemus factum quod transistor phasim mutat 180 graduum quando tensionem input amplificat. L1 et C1 circuitum tank formant et ex his duobus elementis, oscillationes accipiemus. Transformator ad feedback positivum praebendum iuvat (ad hoc postea revertamur) et transistor output amplificat. Hoc constituto, nunc procedamus ad intellegendum operationem circuiti.


Cum alimentatio electrica coniungitur, condensator C1 incipit impleti. Cum plene impletus sit, incipit per inductorem L1 discedere. Energia in condensatore sub forma electrostatica conservata convertitur in energiam electromagneticam et in inductore L1 conservatur. Cum condensator totaliter discidat, inductor iterum condensatorem incipit impleti.


Hoc quia inductores non sinunt currentem per se cito mutari et ideo polaritatem per se mutabit et currentem in eadem directione manere faciet. Condensator iterum incipit impleti et cyclus huiusmodi continuatur. Polaritas per inductorem et condensatorem periodiciter mutatur et ideo signum oscillans ut output accipimus.


Spira L2 per inductionem electromagneticam impletur et hoc ad transistor mittit. Transistor signum amplificat, productum efficiens. Pars huius output feedback positivum systemati redditur.


Feedback positivum est feedback quod cum input in phase est. Transformator mutationem phasim 180 graduum inducit et transistor quoque mutationem phasim 180 graduum inducit. Itaque in toto, 360 graduum phasim accipimus et hoc ad circuitum tank feedbacktur. Feedback positivum necessarium est ad oscillationes sustinendas.


Frequenta oscillationis ab valore inductoris et condensatoris in circuitu tank dependet et datur per:

 

Ubi,

F = Frequenta oscillationis. L1 = valor inductivitatis primarii transformatoris L1. C1 = valor capacitativus condensatoris C1.


bb536373b37e9472008627391dc8d7cb.jpeg


Donum da et auctorem hortare

Suggestus

Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
02/05/2026
Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
01/30/2026
Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
01/29/2026
Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
01/29/2026
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum