6~20kV indoor type complete substation high and low voltage wiring scheme

Master Electrician
Master Electrician
Field: Basic Electrical
0
China

6~20kV indoor type complete substation high and low voltage wiring scheme

屏幕截图 2024-09-27 112842.jpg

Give a tip and encourage the author!
Recommended
Outdoor Substations: Types, Pros & Cons (55kV–765kV)
Outdoor Substations: Types, Pros & Cons (55kV–765kV)
Substations designed for voltage levels ranging from 55 kV to 765 kV are known as outdoor substations. This type of substation requires less construction time but occupies more space. Outdoor substations are mainly divided into pole-mounted substations and foundation-mounted substations.Pole-Mounted SubstationsThis type of substation is used to support distribution transformers with capacities up to 250 kVA. Such transformers represent the cheapest, simplest, and smallest form of distribution. A
Edwiin
11/06/2025
Essential Rules for 3-Level Electrical Distribution
Essential Rules for 3-Level Electrical Distribution
Essential Rules for Three-Level Power Distribution System Design1.Hierarchical and Branch Circuit Distribution(1) Power distribution from the primary main distribution board (distribution cabinet) to secondary distribution boards can be branched; that is, one main distribution board may supply power via multiple branch circuits to several secondary distribution boards.(2) Similarly, power distribution from a secondary distribution board to tertiary switch boxes can also be branched; that is, one
Dyson
11/06/2025
What are the technical measures for loss reduction and energy saving in distribution systems?
What are the technical measures for loss reduction and energy saving in distribution systems?
1.Reasonable Use of TransformersTransformers should be selected with flexible winding configurations according to the power consumption characteristics of industrial enterprises, and load adjustments should be made promptly based on each transformer’s load rate to ensure operation at optimal loading conditions. Three-phase loads on transformers should be kept as balanced as possible; unbalanced operation not only reduces output capacity but also increases losses. Energy-efficient transformers sh
Echo
11/06/2025
What are the advantages of using a common grounding system in power distribution, and what precautions should be taken?
What are the advantages of using a common grounding system in power distribution, and what precautions should be taken?
What Is Common Grounding?Common grounding refers to the practice where a system’s functional (working) grounding, equipment protective grounding, and lightning protection grounding share a single grounding electrode system. Alternatively, it may mean that grounding conductors from multiple electrical devices are connected together and linked to one or more common grounding electrodes.1. Advantages of Common Grounding Simpler system with fewer grounding conductors, making maintenance and inspecti