What are grid system faults?

Encyclopedia
12/03/2024

Types of Faults in Power Grid Systems

Power grid system failure refers to various abnormal conditions that occur in the power system. These faults may affect the normal operation of the power system, leading to equipment damage, power outages, and other issues. The following are several common types of faults in power grids:

1. Short circuit fault

Short circuit fault refers to the phenomenon in which the impedance between conductors of different phases in a power system, or between a conductor and the ground, is significantly reduced, resulting in a sharp increase in current. Short circuit faults can be divided into two types: symmetrical short circuit and asymmetrical short circuit.

  • Symmetric Short Circuit:A fault that involves all three phases is called a symmetrical short circuit. This type of fault maintains the balance of the system and mainly occurs at the terminals of the generator.

  • Asymmetric Short Circuit:A short-circuit fault involving only one phase or two phases is called an asymmetric short circuit. This type of fault causes the system to lose balance and is the most common type of short circuit fault.

2. Phase Failure

Open-phase fault refers to the situation in which one or more phases are disconnected in a power system, leading to asymmetric operation of the system and affecting the normal functioning of equipment.

  • One phase is disconnected:A short circuit between a single phase conductor and ground is the most common type of short circuit fault in an electrical system.

  • Two-phase disconnection:A short circuit between two-phase conductors can also cause an unbalanced condition in the system.

3. Open Circuit Fault

An open-circuit fault refers to a failure in one or more conductors that results in the interruption of a circuit, preventing the normal flow of current. Open-circuit faults can affect the reliability of a system and are commonly known as series faults.

4. Resonance Failure

Resonant faults are generated by resonant circuits composed of inductors, capacitors, and other components in power systems, and can be divided into three types: linear resonance, nonlinear resonance, and parametric resonance.

  • Linear Resonance:The resonance phenomenon generated by the resonant circuit composed of linear elements such as inductors and capacitors.

  • Nonlinear Resonance:Resonance phenomena caused by nonlinear elements (such as ferromagnetic elements) may lead to overvoltage or overcurrent.

  • Parameter Resonance:Resonance phenomena caused by changes in power system parameters (such as frequency, voltage, etc.).

5. Ground Fault

A ground fault refers to an unintended low-impedance connection between a phase conductor in an electrical power system and the ground, which can lead to insulation damage of equipment and increase the risk of failure.

6. Failures caused by natural disasters

Natural disasters such as lightning strikes, heavy rain, strong winds, earthquakes, and floods can also cause damage to power systems, leading to faults.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
Load Frequency Control (LFC) & Turbine Governor Control (TGC) in Power System
Load Frequency Control (LFC) & Turbine Governor Control (TGC) in Power System
Brief Introduction to Thermal Generating UnitsElectricity generation relies on both renewable and non - renewable energy resources. Thermal generating units represent a conventional approach to power production. In these units, fuels such as coal, nuclear energy, natural gas, biofuel, and biogas are combusted within a boiler.The boiler of a generating unit is an extremely complex system. In its simplest conception, it can be visualized as a chamber whose walls are lined with pipes, through which
Edwiin
06/06/2025
Why 3-Phase Power? Why Not 6, 12 or More for Power Transmission?
Why 3-Phase Power? Why Not 6, 12 or More for Power Transmission?
It is well-known that single-phase and three-phase systems are the most prevalent configurations for power transmission, distribution, and end-use applications. While both serve as fundamental power supply frameworks, three-phase systems offer distinct advantages over their single-phase counterparts.Notably, multi-phase systems (such as 6-phase, 12-phase, etc.) find specific applications in power electronics—particularly in rectifier circuits and variable frequency drives (VFDs)—wher
Edwiin
06/05/2025
How Many Poles and Towers are Situated Within a 1-km Span?
How Many Poles and Towers are Situated Within a 1-km Span?
The number of distribution poles and transmission towers within a 1-kilometer stretch of overhead lines varies significantly based on multiple factors, including voltage level, power line type, supporting structure, geographical location, local regulations, and specific grid requirements.In urban areas, distribution utility poles are typically positioned at closer intervals, while in rural regions, they are spaced farther apart. Additionally, the use of taller structures for higher-voltage trans
Edwiin
06/05/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!