What are grid system faults?

12/03/2024

Types of Faults in Power Grid Systems

Power grid system failure refers to various abnormal conditions that occur in the power system. These faults may affect the normal operation of the power system, leading to equipment damage, power outages, and other issues. The following are several common types of faults in power grids:

1. Short circuit fault

Short circuit fault refers to the phenomenon in which the impedance between conductors of different phases in a power system, or between a conductor and the ground, is significantly reduced, resulting in a sharp increase in current. Short circuit faults can be divided into two types: symmetrical short circuit and asymmetrical short circuit.

  • Symmetric Short Circuit:A fault that involves all three phases is called a symmetrical short circuit. This type of fault maintains the balance of the system and mainly occurs at the terminals of the generator.

  • Asymmetric Short Circuit:A short-circuit fault involving only one phase or two phases is called an asymmetric short circuit. This type of fault causes the system to lose balance and is the most common type of short circuit fault.

2. Phase Failure

Open-phase fault refers to the situation in which one or more phases are disconnected in a power system, leading to asymmetric operation of the system and affecting the normal functioning of equipment.

  • One phase is disconnected:A short circuit between a single phase conductor and ground is the most common type of short circuit fault in an electrical system.

  • Two-phase disconnection:A short circuit between two-phase conductors can also cause an unbalanced condition in the system.

3. Open Circuit Fault

An open-circuit fault refers to a failure in one or more conductors that results in the interruption of a circuit, preventing the normal flow of current. Open-circuit faults can affect the reliability of a system and are commonly known as series faults.

4. Resonance Failure

Resonant faults are generated by resonant circuits composed of inductors, capacitors, and other components in power systems, and can be divided into three types: linear resonance, nonlinear resonance, and parametric resonance.

  • Linear Resonance:The resonance phenomenon generated by the resonant circuit composed of linear elements such as inductors and capacitors.

  • Nonlinear Resonance:Resonance phenomena caused by nonlinear elements (such as ferromagnetic elements) may lead to overvoltage or overcurrent.

  • Parameter Resonance:Resonance phenomena caused by changes in power system parameters (such as frequency, voltage, etc.).

5. Ground Fault

A ground fault refers to an unintended low-impedance connection between a phase conductor in an electrical power system and the ground, which can lead to insulation damage of equipment and increase the risk of failure.

6. Failures caused by natural disasters

Natural disasters such as lightning strikes, heavy rain, strong winds, earthquakes, and floods can also cause damage to power systems, leading to faults.

Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.

Difference Between Short Circuit & Overload
Difference Between Short Circuit & Overload
One of the main differences between a short circuit and an overload is that a short circuit occurs due to a fault between conductors (line-to-line) or between a conductor and earth (line-to-ground), whereas an overload refers to a situation where equipment draws more current than its rated capacity from the power supply.Other key differences between the two are explained in the comparison chart below.The term "overload" typically refers to a condition in a circuit or connected device. A circuit
08/28/2025
Difference Between Leading and Lagging Power Factor
Difference Between Leading and Lagging Power Factor
Leading and lagging power factors are two key concepts related to the power factor in AC electrical systems. The main difference lies in the phase relationship between current and voltage: in a leading power factor, the current leads the voltage, whereas in a lagging power factor, the current lags behind the voltage. This behavior depends on the nature of the load in the circuit.What is Power Factor?Power factor is a crucial, dimensionless parameter in AC electrical systems, applicable to both s
08/26/2025
Difference Between Electromagnet and Permanent Magnet
Difference Between Electromagnet and Permanent Magnet
Electromagnets vs. Permanent Magnets: Understanding the Key DifferencesElectromagnets and permanent magnets are the two primary types of materials that exhibit magnetic properties. While both generate magnetic fields, they differ fundamentally in how these fields are produced.An electromagnet generates a magnetic field only when an electric current flows through it. In contrast, a permanent magnet inherently produces its own persistent magnetic field once it has been magnetized, without requirin
08/26/2025
Interpretation of the “Five Mandatory Surveys” for On - site Investigation in the Operation and Maintenance Specialty
Interpretation of the “Five Mandatory Surveys” for On - site Investigation in the Operation and Maintenance Specialty
The power outage and work scopes must be clearly inspectedCollaborate with the site survey leader to confirm the equipment to be maintained and the work area involved. Consider requirements such as the use of special vehicles and large machinery, and safe distances from adjacent energized equipment. Verify on-site whether the proposed power outage scope is sufficient to meet the operational needs.On-site safety measures must be clearly inspectedCollaborate with the site survey leader to verify s
Vziman
08/14/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!