Methods of Voltage Control in Power System

Edwiin
Edwiin
Field: Power switch
China

Methods of Voltage Control in Power System

The voltage within a power system is subject to variation in accordance with load fluctuations. Typically, the voltage is elevated during light - load periods and reduced under heavy - load conditions. To maintain the system voltage within acceptable limits, additional equipment is necessary. This equipment serves to increase the voltage when it is low and decrease it when it is overly high. The following are the methods employed in power systems for voltage control:

  • On - Load Tap Changing Transformer

  • Off - Load Tap Changing Transformer

  • Shunt Reactors

  • Synchronous Phase Modifiers

  • Shunt Capacitor

  • Static VAR System (SVS)

Controlling the system voltage with the aid of a shunt inductive element is referred to as shunt compensation. Shunt compensation is categorized into two types: static shunt compensation and synchronous compensation. In static shunt compensation, shunt reactors, shunt capacitors, and static VAR systems are utilized, while synchronous compensation makes use of synchronous phase modifiers. The methods for voltage control are elaborated in detail below.

Off - Load Tap Changing Transformer: In this approach, voltage control is achieved by altering the turns ratio of the transformer. Before changing the tap, the transformer must be disconnected from the power supply. Tap - changing of the transformer is predominantly carried out manually.

On - Load Tap Changing Transformer: This configuration is used to adjust the turns ratio of the transformer for regulating the system voltage while the transformer is delivering load. The majority of power transformers are equipped with on - load tap changers.

Shunt Reactor: A shunt reactor is an inductive current element connected between the line and the neutral. It compensates for the inductive current originating from transmission lines or underground cables. Shunt reactors are primarily used in long - distance Extra - High - Voltage (EHV) and Ultra - High - Voltage (UHV) transmission lines for reactive power control.

Shunt reactors are installed in the sending - end substation, receiving - end substation, and intermediate substations of long EHV and UHV lines. In long - distance transmission lines, shunt reactors are connected at intervals of approximately 300 km to limit the voltage at intermediate points.

Shunt Capacitors: Shunt capacitors are capacitors connected in parallel with the line. They are installed at receiving - end substations, distribution substations, and switching substations. Shunt capacitors inject reactive volt - amperes into the line and are typically arranged in three - phase banks.

Synchronous Phase Modifier: A synchronous phase modifier is a synchronous motor operating without a mechanical load. It is connected to the load at the receiving end of the line. By varying the excitation of the field winding, the synchronous phase modifier can either absorb or generate reactive power. It maintains a constant voltage under all load conditions and also improves the power factor.
Static VAR Systems (SVS): The static VAR compensator injects or absorbs inductive VAR into the system when the voltage deviates from the reference value, either higher or lower. In a static VAR compensator, thyristors are used as switching devices instead of circuit breakers. In modern systems, thyristor switching has replaced mechanical switching due to its faster operation and the ability to provide transient - free operation through switching control.

Give a tip and encourage the author!
Recommended
Maintenance and Repair Items for 10kV High-Voltage Switchgear
Maintenance and Repair Items for 10kV High-Voltage Switchgear
I. Routine Maintenance and Inspection(1) Visual Inspection of Switchgear Enclosure No deformation or physical damage to the enclosure. Protective paint coating shows no severe rust, peeling, or flaking. Cabinet is securely installed, clean on the surface, and free of foreign objects. Nameplates and identification labels are neatly affixed and not falling off.(2) Check of Switchgear Operating Parameters Instruments and meters indicate normal values (comparable to typical operating data, with no s
Edwiin
10/24/2025
Low-Voltage Vacuum Breaker Coil Types & Failures
Low-Voltage Vacuum Breaker Coil Types & Failures
Trip and Close Coils in Low-Voltage Vacuum Circuit BreakersThe trip and close coils are the core components that control the switching state of low-voltage vacuum circuit breakers. When the coil is energized, it generates a magnetic force that drives a mechanical linkage to complete the opening or closing operation. Structurally, the coil is typically made by winding enameled wire on an insulating bobbin, with an outer protective layer, and the terminals are fixed to the housing. The coil operat
Felix Spark
10/18/2025
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic (PV) Power Generation SystemsA photovoltaic (PV) power generation system is primarily composed of PV modules, a controller, an inverter, batteries, and other accessories (batteries are not required for grid-connected systems). Based on whether it relies on the public power grid, PV systems are divided into off-grid and grid-connected types. Off-grid systems operate independently without relying on the utility grid. They are equipped with energy-s
Encyclopedia
10/09/2025
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(2)
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(2)
1. On a scorching sunny day, do damaged vulnerable components need to be replaced immediately?Immediate replacement is not recommended. If replacement is necessary, it is advisable to do so in the early morning or late afternoon. You should contact the power station’s operation and maintenance (O&M) personnel promptly, and have professional staff go to the site for replacement.2. To prevent photovoltaic (PV) modules from being hit by heavy objects, can wire mesh protective screens be install
Encyclopedia
09/06/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.