Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Why Dry Air is the Best Alternative to SF₆ Gas in Ring Main Units
1. Air-insulated and SF₆ Gas-insulated Ring Main UnitsAir-insulated ring main units primarily integrate load break switches, disconnectors, or a combination of both with grounding capabilities, operated either manually or electrically. These units may also incorporate fuses to control cable input and output lines. Conversely, SF₆ gas-insulated ring main units, commonly referred to as gas-insulated switchgear, utilize SF₆ gas for insulation and arc quenching due to its high dielectric strength, p
08/13/2025
Consult
Tip
Consult
Tip
Global Development and Key Technologies of Solid-Insulated Ring Main Units (RMUs)
Development Status at Home and AbroadToshiba Corporation of Japan developed high-performance epoxy resin materials and casting technology in 1999, and subsequently launched a 24 kV solid-insulated ring main unit (RMU) in 2002. The product line has since been expanded, and the company is now advancing toward higher voltage levels of 72 kV and 84 kV. Holec, originally a European pioneer with advanced design concepts and environmentally friendly manufacturing processes that produce no pollution, wa
08/11/2025
Consult
Tip
Consult
Tip
Current Applications and Future Trends of Solid-Insulated Ring Main Units (RMUs)
1.Current Application Status of Solid-Insulated Ring Main Units in Medium-Voltage Distribution Networks1.1 Widespread Application in Urban Residential AreasThe core components of medium-voltage ring main units (RMUs) primarily consist of load switches and fuses. These units offer several advantages, including a simple structure, compact size, and relatively low cost. Additionally, they effectively improve power quality and enhance the reliability and safety of power supply. Observations indicate
08/11/2025
Consult
Tip
Consult
Tip
Solid-Insulated Ring Main Units: Current Applications and Future Trends in Medium-Voltage Networks
Current Application Status of Solid-Insulated Ring Main Units in Medium-Voltage Distribution Networks(1) Solid-insulated ring main units (RMUs) have been widely applied in urban residential areas and other medium-voltage distribution applications. The core components of medium-voltage RMUs mainly include the load switch and the fuse. These units offer advantages such as a simple structure, compact size, and low cost, while effectively improving power supply parameters and enhancing operational s
08/11/2025
Consult
Tip
Consult
Tip
SF₆ vs. Solid-Insulated RMUs: Which Is Better for Your Power Distribution System?
1 Ring Network Power Supply and Ring Main UnitsWith the advancement of urbanization, the demand for higher reliability in power distribution continues to grow, and an increasing number of users require two or more power supply sources. The traditional "radial power supply" method faces challenges such as difficulties in cable installation, complicated fault detection, and inflexibility in grid upgrades and expansions. In contrast, "ring network power supply" enables dual or multiple power source
08/11/2025
Consult
Tip
Consult
Tip
SF6 Ring Main Units (RMUs): Current Power Supply Methods, Development Prospects, Advantages Over Metal-Clad Switchgear and Conclusions
Current Power Supply Method Using SF6 Ring Main UnitsTo enhance grid performance, the design of traditional SF6 ring main units (RMUs) has been further optimized. A key feature of second-generation SF6 RMUs is the use of a grounded, enclosed epoxy resin housing, with SF6 gas as the insulating medium. Two three-position load switches and one three-position arc-rotating circuit breaker are integrated into a single sealed unit, equipped with a pressure relief safety valve. In the event of arc-quenc
08/09/2025
Consult
Tip
Consult
Tip
Why Does Magnetizing Inrush Current Occur in Arc Furnace Transformers and Its Effects?
Magnetizing inrush current in electric arc furnace transformers is a problem that troubles many electrical engineers. So, why does magnetizing inrush current occur in arc furnace transformers? First, let's understand what magnetizing inrush current is.Magnetizing inrush current refers to the transient current generated in the secondary winding of an arc furnace transformer due to core saturation, increased magnetic field strength, and other factors. This phenomenon is very common during the oper
08/06/2025
Consult
Tip
Consult
Tip
How Arc Furnace Transformers and Sympathetic Inrush Currents Affect Grid Voltage and Mitigation Measures?
An electric arc furnace is a device that melts metal using the high temperature generated by an electric arc. It converts electrical energy into thermal energy through a transformer, then transfers the heat via the arc to the furnace charge, causing it to melt. When the arc furnace starts operating, the transformer load increases suddenly, leading to a drop in grid voltage. Additionally, due to the operational characteristics of the arc furnace, the load continues to rise over a period of time,
08/06/2025
Consult
Tip
Consult
Tip
What is Reactive Power Compensation Technology, Its Optimization Strategies, and Significance?
1 Overview of Reactive Power Compensation Technology1.1 Role of Reactive Power Compensation TechnologyReactive power compensation technology is one of the widely used techniques in power systems and electrical grids. It is primarily employed to improve power factor, reduce line losses, enhance power quality, and increase the transmission capacity and stability of the grid. This ensures that power equipment operates in a more stable and reliable environment, while also boosting the grid&rsquo
08/05/2025
Consult
Tip
Consult
Tip
What Are the Utilization Rate Indicators and Improvement Methods of Power Transmission Transformers?
1. Indicators Related to the Utilization Rate of Power Transmission TransformersThe utilization rate of power transmission transformers needs to consider both the cost of transmitting and distributing electrical energy and the utilization efficiency of the equipment itself. The core indicators mainly include three dimensions: load rate, load factor, and equipment life rate.1.1 Load RateIt refers to the ratio of the actual load at the moment of maximum load to the rated capacity of the transforme
08/04/2025
Consult
Tip
Consult
Tip