Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
What is a substation in electrical engineering?
Substations are critical facilities in power systems used for voltage transformation, power distribution, and controlling the flow of electricity. Their primary functions include:Voltage TransformationSubstations use transformers to convert high voltage electricity to lower voltages, or vice versa, to meet the needs of different users and equipment.Power DistributionSubstations transmit electricity from power plants to various consumption areas, ensuring a stable and reliable power supply.Power
02/05/2025
Consult
Tip
Consult
Tip
Auxiliary contact in switchgears
Auxiliary contacts are essential components in circuit breakers and switchgear, providing critical functionality for control and indication. Here's a breakdown of their purpose and operation:Purpose of Auxiliary Contacts: Breaker Trip & Closing Control: Auxiliary contacts are used in control circuits to manage the supply to the trip coil and closing coil, ensuring proper operation of the circuit breaker. Breaker ON/OFF Indication: These contacts provide signals to indicate whether the b
02/05/2025
Consult
Tip
Consult
Tip
Trip free operating mechanism definition acc to IEEE C37.04
Trip-Free Operation of Medium Voltage Circuit BreakersDefinition and BehaviorThe trip-free operation of medium voltage circuit breakers ensures that, regardless of any closing command, the breaker will open if a tripping signal (either mechanical or electrical) is received. This characteristic guarantees safe and reliable operation under all conditions. The behavior of the circuit breaker under different scenarios is detailed below: Simultaneous Closing and Tripping Signals:If a closing operatio
01/25/2025
Consult
Tip
Consult
Tip
What are smart switchgears?
What is a smart switchgear?A smart switchgear is a kind of electrical equipment that integrates advanced sensor technology, communication technology, automatic control technology, and intelligent analysis technology, etc., to carry out intelligent upgrades on traditional switchgears. It is mainly used for the distribution, control, and protection of electrical energy in the power system. The following is a detailed introduction from aspects such as its functional characteristics, structural comp
01/24/2025
Consult
Tip
Consult
Tip
Air break circuit breakers technical history in high voltage
Air-Blast Circuit Breakers: A Historical OverviewIntroductionAir-blast circuit breakers leverage the superior dielectric strength and thermal properties of compressed air compared to atmospheric air. This technology allows for the design of high-voltage circuit breakers, utilizing an axial blast of compressed air directed at the arc to extinguish it efficiently. For over five decades, this method was the preferred technology for extra-high voltage applications until the advent of SF6 (sulfur hex
01/24/2025
Consult
Tip
Consult
Tip
Relays and circuit breaker combination
Operation Mechanism of a Circuit BreakerEnergy Storage and ReleaseA closed circuit breaker (CB) stores sufficient energy in one form or another to open its contacts. When a protective relay signals to open the circuit, this stored energy is released, causing the circuit breaker to trip and open.Connection Between Relay and Circuit BreakerExcept in special cases where protective relays are mounted directly on the breaker, the connection between the relay and the circuit breaker is typically achie
01/23/2025
Consult
Tip
Consult
Tip
Energisation of back to back(b to b) cables by circuit breaker according to IEC
The energization of a cable by the closing of a circuit breaker (CB) indeed results in a transient inrush current. The characteristics of this inrush current are influenced by several factors within the electrical system. Here is a refined and detailed explanation:Factors Influencing Inrush CurrentApplied Voltage: The voltage level at the moment the CB closes directly affects the magnitude of the inrush current. Higher voltages can lead to higher initial current peaks.Cable Surge Impedance: This
01/22/2025
Consult
Tip
Consult
Tip
Principle of controlled switching (CS) in circuit breaker
Controlled Switching (CS) MethodControlled Switching (CS) is a technique used to eliminate harmful transients by precisely timing the switching operations of circuit breakers (CBs). The closing or opening commands to the CB are delayed in such a way that the contacts make or separate at an optimal phase angle, minimizing transient effects.Key Principles: Voltage Zero Crossing for Closing: To avoid switching transients, the moment of contact closure should ideally occur at the voltage zero crossi
01/21/2025
Consult
Tip
Consult
Tip
Circuit breakers density Monitoring System (including piping) failures in substation
SF6 Gas Density Monitoring System Components and Failure ModesThe SF6 gas density monitoring system comprises three main components: Gas Density Monitor Gas Pipes with Manifold (if applicable) Pressure (or Density) GaugeEach of these components can experience different types of failure modes.Gas Density MonitorGas density monitors are susceptible to several failure modes:• Mechanical Disturbances: The operational density values at which the switch operates can change due to mechanical s
01/20/2025
Consult
Tip
Consult
Tip
Switchgear operating mechanism material and important specifications
Special Considerations for Shaft and Latch BearingsSpecial attention must be paid to the material specifications and design of shaft and latch bearings to ensure smooth operation, even after prolonged periods of inactivity. The moving contacts should still separate within approximately 25 milliseconds when the protection system issues an opening command.Key Design Features:Trip and Close Latches: These components are designed to be relatively lightly loaded to minimize the burden on trip and clo
01/18/2025
Consult
Tip
Consult
Tip