Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Remote Terminal Unit (RTU) role in switchgear automation
Remote Terminal Unit (RTU)A Remote Terminal Unit (RTU) is a microprocessor - based device that plays a crucial role in a Supervisory Control and Data Acquisition (SCADA) system. It acts as an intermediary, transmitting telemetry data from the field to the master station while also being able to modify the state of connected switchgear. This modification can occur based on control messages received from the master station or commands generated internally by the RTU itself. In essence, the RTU ser
05/04/2025
Consult
Tip
Consult
Tip
Why Use VCB Circuit Breakers in HV Transmission, & Not ACB?
What is an Air Circuit Breaker (ACB)?An Air Circuit Breaker (ACB) is a specific kind of circuit breaker. It employs air as the medium for extinguishing electrical arcs. The primary function of an ACB is to safeguard electrical circuits from various issues such as overloads, short - circuits, and other fault conditions. ACBs are widely utilized in both low - voltage and high - voltage electrical systems. They are well - recognized for their dependable performance and the ease with which they can
04/30/2025
Consult
Tip
Consult
Tip
Typical mechanical interlocks role for draw out circuit breakers in LV switchgears according to IEEE standard
Safety Features and Requirements for Circuit Breakers Interlocking to Prevent Unauthorized Movement: To ensure operational safety, it is imperative to prevent the movement of a circuit breaker to or from the connected position when the circuit breaker itself is in the closed state. This safeguard helps avoid potential electrical hazards and damage to the equipment. Pre - closing Conditions: Additionally, measures are in place to prevent the closing of the circuit breaker unless the primary disco
04/30/2025
Consult
Tip
Consult
Tip
Faults and Treatments during the Installation and Debugging of Electrical Equipment in Substations
The arc chutes serve several key functions: Arc Convection - Based Motion, Elongation, and Cooling: Facilitate the movement of the arc, extend its length, and dissipate heat through convection. Arc Compression: Squeeze the arc between the insulating sidewalls, altering its physical characteristics. Gas - Assisted Arc Cooling: Cool the arc by leveraging the gassing properties of the wall materials. Arc Segmentation: Split the arc into multiple shorter, series - connected arcs using metal plates.
04/29/2025
Consult
Tip
Consult
Tip
Percentage Differential Relay
Definition: A percentage differential relay is defined as a type of relay that functions based on the phase difference of two or more similar electrical quantities. It represents an advanced form of differential protection relay. The sole distinction between it and other differential relays lies in the presence of a restraining coil. The percentage differential relay incorporates a restraining coil precisely to address issues stemming from discrepancies in the current ratio when dealing with hig
04/29/2025
Consult
Tip
Consult
Tip
Temperature-Rise test of Large Capacity Generator Circuit Breaker
The temperature rise test is a crucial test for generator circuit breakers to verify their current - carrying capacity. In this test, the maximum test current can reach as high as 35 kA to simulate the real operating environment. The test sample is a complete three - phase installation, but the test is only conducted on a single phase. The air temperature can be adjusted using cooling water.The implementation of this test mainly focuses on the following three aspects, and the layout of the exper
04/29/2025
Consult
Tip
Consult
Tip
Heat pipe in generator circuit breaker (GCB)
An important consideration for a generator circuit breaker is its current - carrying capacity. The rated currents of generators typically span from 3000 A (for 50 MVA units) to 50000 A (for 2000 MVA units). As these currents flow through the circuit breaker, heat is generated. To increase the rated current of a specific circuit breaker, it is essential to enhance the heat transfer to the surrounding environment, ensuring that the temperatures of all components remain within acceptable limits.Con
04/28/2025
Consult
Tip
Consult
Tip
Generator circuit breakers(GCB) role in gas turbine power plants
When starting a gas - turbine generator, its rotor must first be accelerated by external means to approximately 60% of the rated speed. Only then does the start - up process become self - sustaining, meaning the turbine can generate enough power to continue the process independently. To achieve this initial acceleration, energy can be supplied by various means, with a static frequency converter (SFC) being a common choice.Generator circuit breakers (GCBs) play a crucial role in this process. The
04/26/2025
Consult
Tip
Consult
Tip
Testing of Circuit Breaker
Circuit Breaker Testing: Challenges and ProceduresTesting circuit breakers is a far more intricate task compared to testing other electrical equipment such as transformers or machines, primarily due to the extremely large magnitudes of short - circuit currents involved. In contrast, the testing of transformers is typically categorized into two main groups: type tests and routine tests.Type Tests of Circuit BreakersType tests are essential for validating the capabilities and confirming the rated
04/25/2025
Consult
Tip
Consult
Tip
Air Blast Circuit Breaker
Air Blast Circuit Breakers: Operation, Advantages, and TypesAn air blast circuit breaker utilizes compressed air or gas as the arc - interrupting medium. Compressed air is stored in a tank and, when needed, released through a nozzle to generate a high - velocity jet. This jet plays a crucial role in extinguishing the arc that forms when the circuit breaker interrupts the electrical current.Air blast circuit breakers are commonly employed for indoor applications in the medium - high voltage range
04/25/2025
Consult
Tip
Consult
Tip