Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
07/01/2025
Consult
Tip
Consult
Tip
What is included in the operational procedures of a smart electricity meter load switch?
As a frontline operator who deals with smart electricity meters daily, I’m well - versed in the design and operational norms of load switches (both internal and external) in these meters. Below, I’ll break down the technical requirements and practical key points based on my on - site experience for easy reference.I. Basic Understanding of Internal and External Load SwitchesIn the type specifications for single - phase and three - phase smart electricity meters (such as enviro
06/28/2025
Consult
Tip
Consult
Tip
What are the key considerations for photovoltaic transformer selection?
Sizing Principles and Technical Parameters of Photovoltaic TransformersSizing photovoltaic transformers requires a comprehensive consideration of multiple factors, includingcapacity matching, voltage ratio selection, short - circuit impedance setting, insulation class determination, and thermal design optimization. The key sizing principles are as follows:(I) Capacity Matching: Fundamental for Load BearingCapacity matching is thecore prerequisitein sizing photovoltaic transformers. It requires a
06/27/2025
Consult
Tip
Consult
Tip
Research on Field Installation Efficiency of Pad-Mounted Transformers
1. IntroductionTo enhance the quality of power supply services, the power system continuously promotes the reform and upgrading of transformers. As a high - end and advanced equipment, pad - mounted transformers have been increasingly applied in the power system in recent years. Especially in regions like Mexico for projects with a voltage level of 23kV, they play a significant role due to their unique advantages. However, the relatively long installation and construction time has, to a certain
06/16/2025
Consult
Tip
Consult
Tip
Installation Construction Procedure for Pad-Mounted Transformers
1. Scope of ApplicationThis technical specification applies to the installation of pad - mounted transformers.1.1 Construction Process1.2 Standard Construction Process Description2. Construction Preparation(1) Main Machinery and Tools Handling and Hoisting Tools: Truck crane, truck, winch, chain hoist, three - step rack, cribbing, steel wire rope, strap rope, rolling bar. Installation Tools: Bench grinder, electric welding machine, gas welding tools, electric hammer, adjustable wrench, hammer, p
06/16/2025
Consult
Tip
Consult
Tip
How to install the transition joint for the speed measurement rotating sensor of the 10 kV indoor vacuum circuit breaker?
1 Innovation BackgroundRegular mechanical characteristic tests (covering closing/opening time, speed, opening distance, over - travel, three - phase asynchrony, bouncing time, etc.) are crucial for 10 kV indoor vacuum circuit breakers, ensuring reliable power supply and grid stability. Manufacturers typically use the moving - contact linear sensor method for testing, as it accurately reflects performance via consistent motion curves between the linear transmission rod and moving contacts.To ease
06/09/2025
Consult
Tip
Consult
Tip
What are the contents of operation and maintenance for the VS1 indoor high-voltage vacuum circuit breaker?
VS1 - Type Indoor High - Voltage Vacuum Circuit BreakerThe VS1 - type indoor high - voltage vacuum circuit breaker is an indoor device for three - phase AC 50Hz with a rated voltage of 12kV. It is used for the control and protection of electrical facilities in industrial and mining enterprises, power plants, and substations. The circuit breaker arranges the main circuit and the operating mechanism on a special - shaped frame in a front - rear manner, that is, an integral layout. This structural
06/06/2025
Consult
Tip
Consult
Tip
What are the key considerations for recloser selection in Nigeria?
When selecting reclosers for power distribution networks in Nigeria, several critical factors must be addressed to ensure reliable, efficient, and compliant operation. Here's a breakdown of key considerations:1. Voltage Compatibility: 11kV StandardsNigeria’s distribution grid widely operates at the 11kV voltage level. Reclosers must be rated for 11kV to seamlessly integrate into the network. This ensures they can handle the system’s voltage demands, whether in urban, rural, o
06/04/2025
Consult
Tip
Consult
Tip
What are the key factors to consider when selecting a 145kV high-voltage disconnect switch?
1. IntroductionHigh voltage disconnect switches, particularly those rated at 145kV, play a critical role in Southeast Asia's power infrastructure. These switches are essential for isolating electrical equipment during maintenance, ensuring personnel safety and grid stability. Selecting appropriate 145kV high voltage disconnect switches (HVDs) is a complex task, requiring comprehensive consideration of multiple factors to meet the specific demands of the region's power systems.2. Overview of High
05/29/2025
Consult
Tip
Consult
Tip
Installation process and control points of enclosed combined electrical high-voltage switchgear GIS equipment
Analysis of GIS Equipment Installation ProcessPre - installation Preparations for GIS EquipmentFirst, use a crane to lift the equipment to the entrance. Then, insert a crowbar into the groove of the channel steel to move the equipment along the channel steel into the room. It can be received by a roller or a forklift for transfer. Before the equipment installation after the transfer is completed, sufficient preliminary preparations are required. Firstly, the equipment needs to be comprehensively