Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Why is the Grounding Wire Bare and Not Insulated?
Why is Mostly Solid Bare Conductor Used for Grounding Instead of Insulated Wire?A ground wire, also known as a grounding wire or ground conductor, as the name implies, is an electrical wire connected from the transformer and main panel (or distribution board) to the ground rod or earthing plate via an earthing lead buried in the ground or Earth. It is connected to all metallic parts that may come into contact with the human body to prevent electric shocks in case the hot (phase or line) wire acc
04/30/2025
Consult
Tip
Consult
Tip
Closed Loop Control of Drives
In a closed - loop system, the output of the system is fed back to the input, enabling the system to control the electrical drive and self - adjust its operation. Feedback loops in an electrical drive are incorporated to meet the following critical requirements: Torque and Speed Enhancement: To boost the torque and speed performance of the system. Steady - State Accuracy Improvement: To enhance the precision of the system during steady - state operation. Protection: To safeguard the electrical d
04/29/2025
Consult
Tip
Consult
Tip
Resistance & Reactance Grounding
Resistance GroundingIn resistance grounding, the neutral of the electrical system is linked to the ground via one or multiple resistors. This grounding method serves to restrict fault currents, safeguarding the system against transient overvoltages. By doing so, it reduces the risk of arcing grounds and enables effective ground - fault protection.The resistance value employed in a neutral grounding system is critical. As illustrated in the figure below, it should be neither excessively high nor
04/29/2025
Consult
Tip
Consult
Tip
Neutral Grounding
In a neutral grounding system, the neutral point of the electrical system, whether it pertains to a rotating machine or a transformer, is connected to the ground. Neutral grounding is a critical element in power system design, as it significantly influences various aspects of system performance, including how the system responds to short circuits, its overall stability, and the effectiveness of protective measures. A three - phase electrical system can be operated in one of two distinct configur
04/29/2025
Consult
Tip
Consult
Tip
Solid Grounding
A power system is considered effectively grounded or solidly grounded when the neutral points of a generator, power transformer, or grounding transformer are directly linked to the ground via a conductor with negligible resistance and reactance. For a portion or the entire system, it is classified as solidly grounded under the following conditions: when the positive - sequence impedance of the system is greater than or equal to the zero - sequence resistance, and the positive - sequence reactanc
04/29/2025
Consult
Tip
Consult
Tip
Peterson Coil Grounding
A Peterson coil, essentially an iron - core reactor, is connected between the neutral of a transformer and the ground. Its primary function is to limit the capacitive earth - fault current that flows when a line - to - ground fault occurs in an electrical line. This coil is equipped with tappings, which allows for adjustments to match the capacitance characteristics of the electrical system. The reactance of the Peterson coil is carefully selected such that the current passing through the reacto
04/29/2025
Consult
Tip
Consult
Tip
Generator Synchronization
A stationary generator must never be connected to live busbars. When a generator is at standstill, the induced electromotive force (EMF) is zero, which would lead to a short - circuit if connected to live busbars. The process of synchronisation and the associated equipment for verification remain consistent, whether it involves connecting one alternator in parallel with another or linking an alternator to an infinite bus.Contents Synchronisation by Synchronising Lamps Advantages of the Dark Lamp
04/29/2025
Consult
Tip
Consult
Tip
The Design of Substation Relay Protection Fault Information Detection System
I. IntroductionIn recent years, with the continuous expansion of the power grid scale, substations, as crucial nodes in the power system, play a vital role in ensuring the reliability of the entire power grid through their safe and stable operation. Relay protection serves as the first line of defense for the safe operation of substations. The accuracy and rapidity of relay protection are directly related to the stability of the power system. Therefore, effectively detecting the fault informatio
04/28/2025
Consult
Tip
Consult
Tip
Installation Measures for Prefabricated U - shaped Concrete Cable Tunnels in Substations
1. IntroductionCurrently, with the rapid development of the economy and science and technology, and the increasing intelligence of the informatization level, the construction of substations is also becoming more and more intelligent. Among them, cable tunnels are an important means for substations to achieve intelligence. Therefore, in practical applications, higher technical and quality requirements are needed. For example, to meet the needs of complex signal transmission, the cable tunnels in
04/28/2025
Consult
Tip
Consult
Tip
Feeder Protection
Feeder ProtectionDefinitionFeeder protection refers to safeguarding electrical feeders against faults to ensure the uninterrupted power supply of the grid. Feeders transmit electrical energy from substations to the load end. Given their crucial role in the power distribution network, protecting feeders from various types of faults is of utmost importance. The primary requirements for feeder protection are as follows: Selective Tripping: During a short - circuit event, only the circuit breaker cl