Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Relay Protection Types in Substations: A Complete Guide
(1) Generator Protection:Generator protection covers: phase-to-phase short circuits in stator windings, stator ground faults, inter-turn short circuits in stator windings, external short circuits, symmetrical overload, stator overvoltage, single- and double-point grounding in the excitation circuit, and loss of excitation. Tripping actions include shutdown, islanding, limiting fault impact, and alarm signaling.(2) Transformer Protection:Power transformer protection includes: phase-to-phase short
11/05/2025
Consult
Tip
Consult
Tip
Front-Panel Visible Wiring Standards for Electrical Control Panels
Front-panel visible wiring: During manual wiring (not using templates or molds), wiring must be straight, neat, closely attached to the mounting surface, rationally routed, and with secure connections that facilitate maintenance. Wiring channels should be minimized as much as possible. Within the same channel, bottom-layer conductors shall be grouped by main and control circuits, arranged in a single-layer parallel dense layout or bundled, and kept closely attached to the mounting surface. Condu
11/04/2025
Consult
Tip
Consult
Tip
What Are the Common Inverter Fault Symptoms and Inspection Methods? A Complete Guide
Common inverter faults mainly include overcurrent, short circuit, ground fault, overvoltage, undervoltage, phase loss, overheating, overload, CPU malfunction, and communication errors. Modern inverters are equipped with comprehensive self-diagnostic, protection, and alarm functions. When any of these faults occurs, the inverter will immediately trigger an alarm or shut down automatically for protection, displaying a fault code or fault type. In most cases, the fault cause can be quickly identifi
11/04/2025
Consult
Tip
Consult
Tip
What are the causes of dielectric withstand failure in vacuum circuit breakers?
Causes of Dielectric Withstand Failure in Vacuum Circuit Breakers: Surface contamination: The product must be thoroughly cleaned before dielectric withstand testing to remove any dirt or contaminants.Dielectric withstand tests for circuit breakers include both power-frequency withstand voltage and lightning impulse withstand voltage. These tests must be performed separately for phase-to-phase and pole-to-pole (across the vacuum interrupter) configurations.Circuit breakers are recommended to be t
11/04/2025
Consult
Tip
Consult
Tip
What Are the Factors Influencing the Impact of Lightning on 10kV Distribution Lines?
1. Induced Lightning OvervoltageInduced lightning overvoltage refers to the transient overvoltage generated on overhead distribution lines due to nearby lightning discharges, even when the line is not directly struck. When a lightning flash occurs in the vicinity, it induces a large amount of charge on the conductors—opposite in polarity to the charge in the thundercloud.Statistical data shows that lightning-related faults caused by induced overvoltages account for approximately 90% of total fau
11/03/2025
Consult
Tip
Consult
Tip
What Are the Handling Procedures After Transformer Gas (Buchholz) Protection Activation?
What Are the Handling Procedures After Transformer Gas (Buchholz) Protection Activation?When the transformer gas (Buchholz) protection device operates, a thorough inspection, careful analysis, and accurate judgment must be carried out immediately, followed by appropriate corrective actions.1. When the Gas Protection Alarm Signal is ActivatedUpon activation of the gas protection alarm, the transformer should be inspected immediately to determine the cause of operation. Check whether it was caused
11/01/2025
Consult
Tip
Consult
Tip
Harmonic THD Impact: From Grid to Equipment
The impact of harmonic THD errors on power systems must be analyzed from two aspects: "actual grid THD exceeding limits (excessive harmonic content)" and "THD measurement errors (inaccurate monitoring)" — the former directly damages system equipment and stability, while the latter leads to improper mitigation due to "false or missed alarms." When combined, these two factors amplify system risks. The impacts span the entire power chain — generation → transmission → distribution → consumption — af
11/01/2025
Consult
Tip
Consult
Tip
The Future of Intelligent Electrical Rooms: Innovation, Efficiency & Sustainability
What Is the Future of Intelligent Electrical Rooms?The Future of Intelligent Electrical RoomsIntelligent electrical rooms represent a significant upgrade from traditional setups by leveraging technologies such as the Internet of Things (IoT), big data analytics, and cloud computing. These advancements facilitate 24/7 remote monitoring, ensuring optimal safety, reliability, and operational efficiency.Key Trends in Intelligent Electrical Room Development Include: Integration and Innovation through
11/01/2025
Consult
Tip
Consult
Tip
How to Inspect an Electrical Room: Complete Checklist
Electrical Room Inspection: Content and PrecautionsThe electrical room is a critical facility for power equipment, responsible for power supply, distribution, and energy output. Therefore, regular inspection of the electrical room is an essential task.1. Electrical Room Inspection Content: Check the operation and lock of entry/exit doors, ensure door gaps are tight, and verify the floor is level and free of obstructions. Monitor the room’s temperature, humidity, and odor to ensure environmental
11/01/2025
Consult
Tip
Consult
Tip
Handling 35kV Substation Fault Tripping
Analysis and Handling of Fault Tripping in 35kV Substation Operation1. Analysis of Tripping Faults1.1 Line-Related Tripping FaultsIn power systems, the coverage area is extensive. To meet power supply demands, numerous transmission lines must be installed—posing significant management challenges. Especially for special-purpose lines, installations are often located in remote areas such as suburbs to minimize impact on residential life. However, these remote areas have complex environments, makin
10/31/2025
Consult
Tip
Consult
Tip