Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
SF₆ vs. Solid-Insulated RMUs: Which Is Better for Your Power Distribution System?
1 Ring Network Power Supply and Ring Main UnitsWith the advancement of urbanization, the demand for higher reliability in power distribution continues to grow, and an increasing number of users require two or more power supply sources. The traditional "radial power supply" method faces challenges such as difficulties in cable installation, complicated fault detection, and inflexibility in grid upgrades and expansions. In contrast, "ring network power supply" enables dual or multiple power source
08/11/2025
Consult
Tip
Consult
Tip
SF6 Ring Main Units (RMUs): Current Power Supply Methods, Development Prospects, Advantages Over Metal-Clad Switchgear and Conclusions
Current Power Supply Method Using SF6 Ring Main UnitsTo enhance grid performance, the design of traditional SF6 ring main units (RMUs) has been further optimized. A key feature of second-generation SF6 RMUs is the use of a grounded, enclosed epoxy resin housing, with SF6 gas as the insulating medium. Two three-position load switches and one three-position arc-rotating circuit breaker are integrated into a single sealed unit, equipped with a pressure relief safety valve. In the event of arc-quenc
08/09/2025
Consult
Tip
Consult
Tip
Why Does Magnetizing Inrush Current Occur in Arc Furnace Transformers and Its Effects?
Magnetizing inrush current in electric arc furnace transformers is a problem that troubles many electrical engineers. So, why does magnetizing inrush current occur in arc furnace transformers? First, let's understand what magnetizing inrush current is.Magnetizing inrush current refers to the transient current generated in the secondary winding of an arc furnace transformer due to core saturation, increased magnetic field strength, and other factors. This phenomenon is very common during the oper
08/06/2025
Consult
Tip
Consult
Tip
How Arc Furnace Transformers and Sympathetic Inrush Currents Affect Grid Voltage and Mitigation Measures?
An electric arc furnace is a device that melts metal using the high temperature generated by an electric arc. It converts electrical energy into thermal energy through a transformer, then transfers the heat via the arc to the furnace charge, causing it to melt. When the arc furnace starts operating, the transformer load increases suddenly, leading to a drop in grid voltage. Additionally, due to the operational characteristics of the arc furnace, the load continues to rise over a period of time,
08/06/2025
Consult
Tip
Consult
Tip
What is Reactive Power Compensation Technology, Its Optimization Strategies, and Significance?
1 Overview of Reactive Power Compensation Technology1.1 Role of Reactive Power Compensation TechnologyReactive power compensation technology is one of the widely used techniques in power systems and electrical grids. It is primarily employed to improve power factor, reduce line losses, enhance power quality, and increase the transmission capacity and stability of the grid. This ensures that power equipment operates in a more stable and reliable environment, while also boosting the grid&rsquo
08/05/2025
Consult
Tip
Consult
Tip
What Are the Utilization Rate Indicators and Improvement Methods of Power Transmission Transformers?
1. Indicators Related to the Utilization Rate of Power Transmission TransformersThe utilization rate of power transmission transformers needs to consider both the cost of transmitting and distributing electrical energy and the utilization efficiency of the equipment itself. The core indicators mainly include three dimensions: load rate, load factor, and equipment life rate.1.1 Load RateIt refers to the ratio of the actual load at the moment of maximum load to the rated capacity of the transforme
08/04/2025
Consult
Tip
Consult
Tip
Intelligent Surge Arrester Monitoring: Trends, Challenges & Future Outlook
1. Current Status and Shortcomings of Online MonitorsCurrently, online monitors are the most commonly used tools for surge arrester monitoring. While they can detect potential defects, they have significant limitations: manual on - site data recording is required, precluding real - time monitoring; and post - collection data analysis adds to operational complexity. IoT - based intelligent monitoring overcomes these issues—collected data is uploaded via the IoT to processing platforms,
07/31/2025
Consult
Tip
Consult
Tip
Enhancing Surge Arrester Online Monitors: Key Improvements for Precision, Fault Diagnosis, and Reliability
1 Significance of Surge Arrester Online Monitors1.1 Enhance Power System Safety, Reduce Lightning DamageDuring lightning strikes, surge arresters play a core role in discharging overvoltage. Online monitors ensure arrester stability, detect potential faults in real - time, and trigger alarms for timely intervention—effectively reducing lightning - induced damage to power equipment and systems, and maintaining stable operation.1.2 Real - Time Status Monitoring, Improve Maintenance Effic
07/30/2025
Consult
Tip
Consult
Tip
Ensuring Stability and Safety in Communication Cable Installation for Protective Spaces
In the context of deep integration of informatization and intelligence, protective spaces, as core carriers of critical communication systems, their stability and safety directly impact information transmission reliability and infrastructure operational efficiency. Thus, analyzing core difficulties (environmental adaptability matching, electromagnetic compatibility design, construction precision control) in communication cable installation in protective spaces holds significant engineering value
07/29/2025
Consult
Tip
Consult
Tip
Technical Features Application and Standards of 500kV Dry-type Shunt Reactors in Brazil
1 Technical Features and Standard References of 500kV Dry - type Shunt Reactors1.1 Technical FeaturesThe 500kV dry - type shunt reactor, an oil - free power device for ultra - high - voltage transmission systems, boasts core features like advanced insulation, innovative heat dissipation, optimized electromagnetic design, and modular structure. These advantages, outperforming traditional oil - immersed reactors, also drive new technical standard demands. Advanced Insulation: Using epoxy resin cas
07/24/2025
Consult
Tip
Consult
Tip
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.