RDV-34.5 Dead Tank Vacuum Air Circuit Breaker drawing
Drawings · ROCKWILL

RDV-34.5 Dead Tank Vacuum Air Circuit Breaker drawing

SF6‑Free Dead‑tank Dry‑Air Vacuum Circuit‑breaker, rated 34.5kV, max 3150A rated current, 31.5‑40kA short‑circuit breaking. Earthed metal tank, vacuum interrupter with dry‑air insulation, spring operating mechanism, outdoor‑sited, greenhouse‑gas‑free.

Add us on Google
Updated2026.10
LanguageEnglish
FilePDF · 125.6 KB
SF6-Free Dead tank Circuit breakerDead Tank Vacuum Air Circuit BreakerDry‑Air Vacuum Circuit‑breaker

Document description

This document introduces SF6‑Free Dead‑tank Dry‑Air Vacuum Circuit‑breaker complying with IEC 62271‑100, IEC 62271‑1:2017 and IEC 62271‑4:2022 international high‑voltage switchgear standards.

It adopts earthed metal dead‑tank construction. Arc interruption is realised by vacuum interrupter, while dry clean dry‑air serves as tank insulation medium with zero SF6. Equipped with spring‑type operating mechanism for three‑phase linked operation. Documentation covers general assembly drawing, mounting base and bushing layout.

It defines foundation requirement, hoisting instruction, primary & secondary wiring boundary, dry‑air tightness management, site acceptance test items, periodic inspection, troubleshooting and end‑of‑life disposal.

Suitable for outdoor application in substations and renewable‑energy boost stations, complying with global greenhouse‑gas‑restriction requirements.

Related Products

Frequently asked questions

General‑assembly outline drawing, foundation drawing, bushing layout and primary/secondary wiring diagrams are available. Full set of IEC‑compliant type‑test certificates are supplied. Hoisting, installation & commissioning guidance and tender‑phase technical consultation are supported.

Retrofit is feasible if foundation, terminal pad and secondary interfaces are compatible. Verify equipment weight, gravity centre and bushing outlet position. Project compliance documents and acceptance test items differ from SF6 type; gas‑related tests are replaced by dry‑air humidity and tightness inspection.

SF6 procurement, filling, gas recovery and waste‑gas handling are eliminated. Nevertheless, periodic tank tightness check and internal humidity monitoring are still required. There is no SF6 density relay; tank condition is evaluated by annual tightness & humidity measurement. Maintenance logic for vacuum interrupter remains similar to traditional dead‑tank breaker.

Arc‑extinction is achieved by vacuum interrupter, while dry clean dry‑air provides phase‑to‑phase and phase‑to‑earth insulation inside metal tank. Short‑circuit arc is quenched inside vacuum interrupter. Zero SF6 greenhouse gas is applied throughout the unit.

Comments

Share your question or perspective
WhatsApp
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register