Application Solutions for Compact Substations in Urban Power Grids

As a vital component of modern power systems, compact substations have become key equipment for urban grid upgrades and transformations due to their advantages of factory prefabrication, easy installation, small footprint, safety, and reliability. With accelerating urbanization, compact substations are evolving from traditional distribution equipment into green, smart energy nodes by integrating renewable energy, energy storage systems, and intelligent monitoring technologies. Based on the latest technical specifications and application scenario analysis, this solution proposes rational configuration and intelligent transformation strategies for compact substations in urban grids, aiming to enhance power supply quality, reduce operational costs, and promote low-carbon grid development.

1. Analysis of Technical Features and Advantages of Compact Substations

1.1 Core Design Philosophy
Utilizes fully enclosed, modular design, integrating high-voltage switchgear, distribution transformers, and low-voltage distribution devices within a single enclosure, achieving a "factory prefabrication + on-site assembly" model. According to the 2025 General Technical Specifications for Compact Substations, the enclosure protection level is ≥IP55, capable of withstanding harsh environments like salt spray.

1.2 Six Core Advantages

  • Short Construction Cycle:Installation to commissioning takes only 5-8 days, reducing investment by 40%-50% compared to conventional substations.
  • Space Saving:A 4000kVA compact substation occupies ≤300 m², only 1/10th the area of a conventional substation.
  • High Safety:Fully enclosed insulation structure with no exposed live parts, achieving "zero electric shock accidents".
  • Strong Automation:Supports "Four Tele" functions (Telemetry, Teleindication, Telecontrol, Teleregulation), meeting unmanned operation requirements.
  • Flexible Configuration:Modular design adapts to diverse urban grid scenarios.
  • Easy Maintenance:Standardized components support rapid replacement, minimizing outage time.

1.3 Technical Structure Classification

Type

Layout

Key Features

Volume Comparison

European Compact Substation

"In-line" Separate Compartments

High-voltage cabinet, transformer, and low-voltage cabinet in independent compartments. Flexible cabinet selection, but relies on forced ventilation for cooling; larger volume.

Baseline (Largest)

American Compact Substation

"Combined" Integrated

High-voltage load switch, fuses, and transformer integrated in an oil tank. Smallest volume. However, oil-immersed fuses prone to carbonization; maintenance requires outage; lacks sufficient phase-loss protection.

1/5 - 1/3 of European type

Domestic Compact Substation

"Improved In-line" Separate Compartments

High-voltage cabinet, transformer, and low-voltage cabinet in independent but compactly linked compartments. Adds safety interlocks and intelligent monitoring:
1. Safety Interlock: Mechanical interlock between grounding switch and main switch ensures absolute power-off safety during maintenance.
2. Fuse Protection: Single fuse triggers three-phase trip + lockout to prevent phase-loss operation.
3. Intelligent Monitoring: Automatic oil temperature protection, remote "Four Tele" functions.
4. Enhanced Protection: Double-layer roof insulation + Aluzinc-coated steel plate anti-corrosion, lifespan ≥20 years.

1/3 - 1/2 of European type

2. Typical Urban Grid Application Scenarios and Configuration Plans

2.1 Residential Area Scenario

  • Case:Residential complex (24,000 m², 398 households), distribution transformer capacity 630kVA.
  • Configuration Recommendations:
  • Type:500-1000kVA, IP55 protection.
  • Landscape Design:Enclosure with advertising lightbox panels, rooftop PV installation.
  • Reactive Power Compensation:Configured at 40%-50% of capacity, 10-loop automatic compensation device.
  • Low-Voltage Outgoing Lines:15-25 loops (including 1-3 spares).

2.2 Commercial Center Scenario

  • Case:Shopping mall (109,000 m² complex), using eco-friendly gas-insulated ring main unit (RMU).
  • Configuration Recommendations:
  • Capacity:1250-2000kVA, ring-main type connection.
  • Intelligent Monitoring:5G network slicing + SM4/SM2 encryption, supports AI equipment status analysis.
  • Reactive Power Compensation:Configured at 50%-60% of capacity, 20-30 loop power supply system.

2.3 Industrial Park Scenario

  • Case:Parking lot charging station, using 1250kVA ring-main type compact substation.
  • Configuration Recommendations:
  • Capacity:800-2000kVA.
  • Energy Storage Integration:15%-20% of main transformer capacity, recommended 6.25MWh liquid-cooled energy storage system.
  • Protection Requirements:Enclosure equipped with lifting mechanism to ensure no deformation during transport/installation.

2.4 Comparison of Key Parameters Across Three Scenarios

Application Scenario

Capacity Range

Connection Type

Reactive Power Compensation Ratio

Special Configurations

Residential Area

500-1000kVA

Terminal Type

40%-50%

Landscape integration, PV self-supply

Commercial Center

1250-2000kVA

Ring-Main Type

50%-60%

5G network slicing, multi-loop supply

Industrial Park

800-2000kVA

Ring-Main Type

40%-60%

Energy storage integration, liquid cooling

3. Economic Benefit Analysis

3.1 Investment Cost Savings:

  • Example: 35kV single-transformer substation, 4000kVA scale:
  • Compact substation saves over 1 million yuan compared to conventional substation;
  • Saves approximately 2700 square meters of land area.

3.2 Operation & Maintenance Cost Reduction:

  • Adoption of advanced technologies like oil-free equipment enables condition-based maintenance, saving approx. 100,000 yuan annually in O&M costs.

3.3 Integrated Solution Economics (2025 Trend):

  • Falling energy storage technology costs (system cost ≤0.6 yuan / Wh):
  • "PV + Compact Substation + Energy Storage" solution can shorten the investment payback period to within 8 years.

Key Data Table

Item

Compact Substation Advantage

35kV/4000kVA Investment

Saves over 1 million yuan

Land Area Occupied

Saves approx. 2700 m²

Annual O&M Cost

Saves approx. 100,000 yuan

Integrated Solution Payback Period

≤8 years (with energy storage & subsidies)

4. Compact Substation Implementation Scenarios

4.1 Priority in New Construction:

  • Prioritize the use of compact substations in new residential complexes, commercial centers, and industrial parks, leveraging their small footprint and easy installation advantages.

4.2 Urban Grid Renovation and Replacement:

  • Gradually replace traditional substations with compact substations in urban grid upgrade projects to enhance grid flexibility and reliability.

4.3 Zero-Carbon Pilot Exploration and Innovation:

  • Implement integrated solutions combining PV + Energy Storage + Compact Substation.
06/16/2025
Recommended
Procurement
Analysis of Advantages and Solutions for Single-Phase Distribution Transformers Compared to Traditional Transformers
1. Structural Principles and Efficiency Advantages​1.1 Structural Differences Affecting Efficiency​Single-phase distribution transformers and three-phase transformers exhibit significant structural differences. Single-phase transformers typically adopt an E-type or ​wound core structure, while three-phase transformers use a three-phase core or group structure. This structural variation directly impacts efficiency:The wound core in single-phase transformers optimizes magnetic flux distribution, ​
Procurement
Integrated Solution for Single Phase Distribution Transformers in Renewable Energy Scenarios: Technical Innovation and Multi-Scenario Application
1. Background and Challenges​The distributed integration of renewable energy sources (photovoltaics (PV), wind power, energy storage) imposes new demands on distribution transformers:​Volatility Handling:​​Renewable energy output is weather-dependent, requiring transformers to possess high overload capacity and dynamic regulation capabilities.​Harmonic Suppression:​​Power electronic devices (inverters, charging piles) introduce harmonics, leading to increased losses and equipment aging.​Multi-Sc
Procurement
Single-Phase Transformer Solutions for SE Asia: Voltage, Climate & Grid Needs
1. Core Challenges in the Southeast Asian Power Environment​1.1 ​Diversity of Voltage Standards​Complex voltages across Southeast Asia: Residential use often 220V/230V single-phase; industrial zones require 380V three-phase, but non-standard voltages like 415V exist in remote areas.High-voltage input (HV): Typically 6.6kV / 11kV / 22kV (some countries like Indonesia use 20kV).Low-voltage output (LV): Standardly 230V or 240V (single-phase two-wire or three-wire system).1.2 ​Climate and Grid Condi
Procurement
Pad-Mounted Transformer Solutions: Superior Space Efficiency and Cost Savings over Traditional Transformers
1.Integrated Design & Protection Features of American-Style Pad-Mounted Transformers1.1 Integrated Design ArchitectureAmerican-style pad-mounted transformers employ a combined design integrating key components - transformer core, windings, high-voltage load switch, fuses, arresters - within a single oil tank, using transformer oil as both insulation and coolant. The structure consists of two main sections:​Front Section:​​High & Low Voltage Operation Compartment (with elbow plug-in conne
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.