The medium-voltage incoming line, transformer and low-voltage distribution are integrated into a factory-tested assembly. It features dual-transformer, dual-busbar N+1 redundancy, with switching logi
The Rockwell Energy data center prefabricated power distribution unit integrates medium-voltage incoming lines, transformers, and low-voltage distribution into a factory-tested steel frame.
It supports N+1 redundant operation with dual transformers and dual low-voltage sections, enabling rapid scalability as the data center is commissioned in phases. Its open-frame design facilitates easy inspections and reduces fault-repair time.

| Parameter |
Rockwell Energy Data Center Power Distribution Unit |
Standard anchor point |
| Rated voltage |
Medium voltage: 12/24/35 kV; Low voltage: 400–800 V |
IEC 62271-200 |
| Transformer |
Dry-type or oil-immersed, standard series 0.63–3.6 MVA |
IEC 60076 / 60076-11 |
| Low-voltage outgoing line |
Multiple solutions for circuit breakers/fuse disconnect switches, with current ratings customized according to the load. |
IEC 61439 |
| Protection level |
IP43 / IP54 (outdoor) / IP31 (indoor) |
IEC 60529 |
| Redundant structure |
Dual transformers + dual low-voltage sections, N+1 |
Project Architecture Design |
| Communication |
IEC 61850 / Modbus, interfacing with BMS/DCIM |
— |

| Comparison item |
Traditional distribution room |
Rockwell Energy Prefabricated Distribution Unit |
| Production cycle |
Civil construction + installation + commissioning for several months |
Factory testing + on-site joint commissioning—significantly shortened. |
| Redundant implementation |
On-site multi-cabinet assembly and interlocking commissioning |
Dual-variable, dual-stage, single-lever integration—logic validated at the factory |
| Expand capacity |
Expand the distribution room |
Add a skid-mounted unit in parallel. |
| Operations and Maintenance |
Inspection of confined spaces is restricted. |
Open-view visual inspection, MTTR reduced |
| Quality |
On-site installation fluctuations |
Complete set of routine tests before leaving the factory |

| Project |
Acceptance value |
Standard anchor point |
| Transformer temperature rise |
Dry-type/Oil-type transformers according to IEC 60076-2/60076-11 |
IEC 60076 Series |
| Redundancy switching |
A disconnection segment with seamless load transfer (experimental verification) |
Project Acceptance Outline |
| Protection level |
Measured according to installation methods IP31/IP43/IP54 |
IEC 60529 |
| Communication |
61850/Modbus point table verification passed |
Project acceptance |
Standard IEC 61850 / Modbus interface; point table delivered with the product; optional remote monitoring platform integration available.
We recommend dry-type transformers (oil-free, low fire risk, compliant with IEC 60076-11). If there are specific requirements for capacity or cost, consider an oil-immersed transformer solution equipped with an oil tank and fire-fighting interlock.
The dual-transformer, dual-segment design is optimized based on load rate (with each segment capable of handling the full load). Redundancy is concentrated in the transformers and low-voltage sections, significantly reducing the need for two separate switchgear rooms.