1 Introductio
Energia venti est fontis renovabilis cum potentiiali discentivo significativo. In recentibus annis, technologia aerogenica adtexit attentionem scholarum universali. Quamquam directionem clavem pro discentiva aerogenica, technologia variabilis velocitatis et frequentiae constantis (VSCF) utitur systemate generatoris venti geminato quasi solutione optimata. In hoc systemate, circuitus statoris generatoris connectuntur directe ad rete, dum control VSCF efficitur per regulandum frequentiam, amplitudinem, phasem et sequentiam phasorum alimenti rotoris. Quia converter tantum transmittit potentiam slip, eius capacitas potest notabiliter minui.
Hodie systemata generatoris venti geminati principaliter utuntur converteribus AC/AC vel AC/DC/AC. Converteres AC/AC fere sunt substituti a converteribus AC/DC/AC fontis tensionis propter eorum harmonicos altos, factorem potentiae input parvum, et dispositivos potentiae excessivos. Licet converteres matriciales fuerint explorati pro systematibus geminatis, structura eorum complexa, exigentia alta tensionis, et control non decoupled input/output limitant adoptionem in applicationibus aerogenis.
Hoc studium developit systema aerogenum geminatum fontis tensionis AC/DC/AC controlatum per duos DSPs. Converter lateris retis adoptat control vectorial orientatum ad tensionem, et converter lateris rotoris utitur control vectorial orientatum ad fluxum statoris. Experimenta confirmant quod systema supportat flumen potentiae bidirectionale, regulationem independentem factoris potentiae input/output, distortionem harmonicam parvam, operationem stabilam latam, et generationem potentiae optima ex fontibus instabilibus sicut ventus.
2 Configuratio Systematis
Ut monstratur in Figura 1, systema constat ex quinque partibus:
Detalhes Claves
3 Control Vectorial pro Generatore Geminato
3.1 Principia Controlis
In frame rotationis synchronae (d-axis alignata cum fluxu statoris), modello generatore geminato est:
usd=Rsisd+dψsddt−ωsψsq{u_{sd} = R_s i_{sd} + \frac{d\psi_{sd}}{dt} - \omega_s \psi_{sq}}usd=Rsisd+dtdψsd−ωsψsq
usq=Rsisq+dψsqdt+ωsψsd{u_{sq} = R_s i_{sq} + \frac{d\psi_{sq}}{dt} + \omega_s \psi_{sd}}usq=Rsisq+dtdψsq+ωsψsd
urd=Rrird+dψrddt−ωslipψrq{u_{rd} = R_r i_{rd} + \frac{d\psi_{rd}}{dt} - \omega_{\text{slip}} \psi_{rq}}urd=Rrird+dtdψrd−ωslipψrq
urq=Rrirq+dψrqdt+ωslipψrd{u_{rq} = R_r i_{rq} + \frac{d\psi_{rq}}{dt} + \omega_{\text{slip}} \psi_{rd}}urq=Rrirq+dtdψrq+ωslipψrd
Aequationes fluxus:
ψsd=Lmims+Lsisd=Lmims{\psi_{sd} = L_m i_{ms} + L_s i_{sd} = L_m i_{ms}}ψsd=Lmims+Lsisd=Lmims
ψsq=−Lmirq{\psi_{sq} = -L_m i_{rq}}ψsq=−Lmirq
ψrd=Lrird+Lmisd{\psi_{rd} = L_r i_{rd} + L_m i_{sd}}ψrd=Lrird+Lmisd
ψrq=Lrirq+Lmisq{\psi_{rq} = L_r i_{rq} + L_m i_{sq}}ψrq=Lrirq+Lmisq
Aequatio torque:
Te=−npLmimsirqLs{T_e = -\frac{n_p L_m i_{ms} i_{rq}}{L_s}}Te=−LsnpLmimsirq
Neglecting stator resistance voltage drop, stator flux satisfies:
ψsd≈usq/ωs,ψsq≈0{\psi_{sd} \approx u_{sq}/\omega_s, \quad \psi_{sq} \approx 0}ψsd≈usq/ωs,ψsq≈0
Strategia controlis:
3.2 Controlis Retis
4 Controlis Vectorialis Rectificatoris Lateris Retis
In frame rotationis synchronae duobus phasis (d-axis alignata cum tensione phase-A), modello rectificatoris PWM est:
ud=Ldiddt+Rid−ωsLiq+sdudc{u_d = L\frac{di_d}{dt} + R i_d - \omega_s L i_q + s_d u_{dc}}ud=Ldtdid+Rid−ωsLiq+sdudc
uq=Ldiqdt+Riq+ωsLid+squdc{u_q = L\frac{di_q}{dt} + R i_q + \omega_s L i_d + s_q u_{dc}}uq=Ldtdiq+Riq+ωsLid+squdc
Cdudcdt=32(sdid+sqiq)−iload{C\frac{du_{dc}}{dt} = \frac{3}{2}(s_d i_d + s_q i_q) - i_{\text{load}}}Cdtdudc=23(sdid+sqiq)−iload
Aequationes potentiae:
P=udid,Q=udiq{P = u_d i_d, \quad Q = u_d i_q}P=udid,Q=udiq
Logica controlis:
5 Resultata Experimentalia
Verificationes Claves:
6 Conclusio
Hoc studium developit systema aerogenum geminatum fontis tensionis AC/DC/AC basatum super duos DSPs. Combinatum cum control vectorial orientatum ad tensionem lateris retis et control vectorial orientatum ad fluxum statoris lateris rotoris, experimenta demonstrant: