• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


ZGS11-400KVA Pad-Mounted Transformer

  • ZGS11-400KVA Pad-Mounted Transformer

Key attributes

Brand ROCKWILL
Model NO. ZGS11-400KVA Pad-Mounted Transformer
Rated voltage 10kV
Rated capacity 400kVA
Series ZGS

Product descriptions from the supplier

Description

Product Description
The Rockwill Pad-Mounted Transformer is an innovative integrated power distribution solution that combines the transformer body, high-voltage load switch, fuse system and related auxiliary equipment into a single compact unit. Utilizing a fully insulated and sealed design with all major electrical components immersed in insulating oil, this product achieves exceptional space efficiency while maintaining high performance. Supporting both loop and radial network configurations, it offers flexible adaptation to various distribution network requirements, making it particularly suitable for space-constrained installation sites. Our design philosophy integrates safety protection with space optimization, ensuring reliable power supply while significantly reducing initial investment and operational maintenance costs.

Key Features & Advantages

Compact Integrated Design

  • Adopts unified construction with volume only 1/3 of European-style substations of equivalent capacity

  • Optimized internal layout reduces footprint by over 40%

  • Pre-assembled unit enables significantly shortened installation time

Multi-level Safety Protection

  • Fully insulated structure effectively prevents electrical hazards

  • Dual-fuse protection system (primary fuse + backup fuse)

  • Hermetically sealed tank prevents oil deterioration, extending service life

Outstanding Performance

  • Optional silicon steel or amorphous alloy core to meet different efficiency requirements

  • Plug-in cable connectors for convenient and reliable installation

  • Special anti-corrosion treatment for harsh environment adaptability

Smart Maintenance Features

  • Reserved smart monitoring interfaces for remote supervision

  • Multiple status indicators including oil temperature and level

  • Modular design facilitates future maintenance and upgrades

Basic Info

Typical Applications

Urban Grid Modernization

  • Power capacity upgrades for older residential areas

  • Street lighting distribution systems

  • Commercial complex power supply projects

Industrial Park Power Supply

  • Standardized factory power distribution

  • Logistics warehouse center electrical systems

  • Data center backup power solutions

Public Facility Power Supply

  • Critical locations like schools and hospitals

  • Transportation hub power security

  • Municipal facility electrical infrastructure

Product parameters

Environmental conditions

  • High ambient temperature:+40°C

  • Low ambient temperature: -45°C

  • Altitude: <1000m

  • The Criteria of Relative Humidity(RH): Daily mean

  • RH would not be more than 95%; Monthly mean AH would not be more than

  • 90%

  • Installation location: Install in a place free of fire, explosion hazard and

  • chemical corrosive gas and well ventilated areas

  • Inclination of installation location: not more than 3 degrees

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.