• 11kV 20kV 35KV Pad Mounted Transformer(Prefabricated Substation)
  • 11kV 20kV 35KV Pad Mounted Transformer(Prefabricated Substation)
11kV 20kV 35KV Pad Mounted Transformer(Prefabricated Substation)
discuss personally
Model
ZGS-13/1000
ZGS-13/2000
ZGS-13/2500
ZGS-13/250
Basic info
Brand ROCKWILL
Model NO. ZGS-13 Series Pad Mounted Transformer
Capacity 250kVA
Series ZGS
Product Detail

Product overview:

The ZGS-13 Series Pad Mounted Transformer delivers a cost-effective, high-reliability, and intelligent solution for urban power distribution. This 250 kVA pad mounted transformer integrates a transformer, switchgear, fuses, tap changers, low-voltage distribution devices, and auxiliary equipment, supporting configurations for energy metering, reactive power compensation, low-voltage shunting, and more.

Designed for 50Hz/60Hz AC systems with a maximum operating voltage of 38.5kV, it suits diverse applications in industrial parks, urban residential areas, commercial centers, high-rise buildings, and other urban infrastructure.

Widely exported to North America, East Asia, Southeast Asia, and the Middle East, the series offers OEM/ODM services to meet customized needs. It complies with international and domestic standards, including ANSI C57, IEEE, DOE, CSA, IEC 60067, GB 1094, GB 17467-2010, GB/T 14048.8.1, and GB 4208.

Product Advantages

Cutting-Edge Technology

  • Fully Enclosed Insulation: Ensures safe, reliable operation with the structure isolating internal components from external hazards.

  • Optimal Performance: Features low loss, noise, and temperature rise, coupled with exceptional overload capacity and sudden short-circuit resistance.

  • Flexible Configuration: Supports both terminal and ring network systems, enabling easy conversion to enhance power supply reliability.

  • Cost-Efficient Operation: Requires minimal maintenance, offers user-friendly operation, and reduces overall equipment costs.

Enclosure Design

  • Premium Materials: Constructed from cold-rolled high-quality hot-dip galvanized steel sheets for corrosion resistance.

  • Precision Manufacturing: Laser CNC cutting, drilling, and bending ensure mm-level processing accuracy.

  • Durable Coating: Surface treated with electrostatic spray paint, guaranteeing 30+ years of anti-aging performance.

  • Core Component: Integrates low-loss oil-immersed transformers manufactured by WONE Electric for stable energy conversion.

Processing & Assembly Standards

  • Skilled Workforce: Assembly technicians undergo at least 6 months of specialized training.

  • Automated Wiring: Secondary circuits are cut by automatic equipment to ensure wiring reliability.

  • Torque Control: Bolts are tightened with power tools to meet precise torque specifications.

  • Busbar Fabrication: Copper busbars are CNC-punched and bent for consistent conductivity.

  • Rigorous Testing: Comprehensive pre-delivery inspections ensure seamless on-site operation.

Company Strengths

  • Certifications: Holds authoritative credentials including ISO, CE, CB, UL, etc.

  • Quality System: Implements a perfect SQA management system to maintain product excellence.

  • Comprehensive Services: Provides quick quotation, electrical design support, and OEM/ODM customization.

  • Logistics Efficiency: Ensures short lead times and global delivery capabilities.

  • After-Sales Support: Offers a full-service warranty system, including factory visits for quality verification.

Product parameters:

Rated Voltage: 10kV, 11kV, 13.8kV, 20kV, 33kV, 34.5kV, 35kV
Maximum Operating Voltage: 38.5kV

Operating Conditions

Temperature Parameters

  • Maximum daily temperature: 40°C

  • Minimum daily temperature: -25°C

  • Maximum daily temperature difference: 25K

  • Average temperature of hottest month: 30°C

  • Maximum annual average temperature: 20°C

  • Average daily relative humidity: ≤95%

  • Average monthly relative humidity: ≤90%

  • Altitude: ≤1000m

  • Solar Radiation Intensity: 0.1W/cm²

  • Maximum Ice Thickness: 10mm

  • Wind Speed (10m Height, 10min Average): 35m/s

  • Ground Horizontal Acceleration: 2m/s²

  • Installation Environment: Outdoor

  • Pollution Grade: Ⅲ

Ordering Instructions

When placing an order, customers are required to provide the following information to ensure precise customization:

Electrical Diagrams

Main loop scheme di:agram and secondary loop system diagram.

Auxiliary circuit electrical schematic diagram and wiring terminal layout.

Mechanical Drawings:

Equipment layout drawing, combination drawing, and floor plan.

Component Specifications:

Brand, model, specification, and quantity of main electrical components.

Cabling Details:

Incoming and outgoing line configurations and cable specifications.

Surface Finishing:

Equipment surface color (specified by RAL chromatic number).

Special Requirements:

Any additional customizations can be negotiated with WONE Electric for tailored solutions.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!