YSF series pressure relief valve mainly applied to oil-immersed transformers. It can to load tap changer and other oil- immersed electric equipments. Good protective performance. When the inner pressure raches the setting value, it can be opend and closed automatically and the pressure in the will keep normal. It is used as protective to avoid accidents when the pressure in the tank is very high.


Technology parameters

Sequence 

number

Injection 

caliber

Outside 

diameter 

D

Even the 

pipe inner

 d

Body always

 high

 H

Installing hole

 center size

Screw hole 

diameter and

 quantity

Sealing ning 

outside diameter

 A

Injection cover

 outside diameter

 B

JB/4

25

112

45

94

90

M10X3

64

60

JB/5

50

156

80

120

130

M12X4

107

100

JB/6

80

195

130

150

170

M12X6

207

213

JB/7

130

265

155

180

236

M12X6

274

281

Technical parameters for YSF series pressure relief valve:

Type

Outside 

diameter

 D

Hole on 

the box cover

 Φ D

Body always

 high H

The box cover

 and body always

 high H

Thread X Pitch

MXP

φ25

60

40

70

90

38X2(33X2)

φ50

100

80

80

105

60X2

 

If you need to know about more parameters , Please check the model selection manual.↓↓↓ 

Know your supplier
Transformer Parts
As a key component in power systems, the stable operation of transformers relies on high-quality accessories. Wone specializes in the sales and supply of transformer accessories, delivering high-quality products and fast response services through an efficient and professional supply chain system. Core Strengths Comprehensive Product Range: Includes insulation materials, cooling components, protection devices, and various structural parts to meet diverse needs. Global Supply Chain Network: Integrates high-quality supplier resources to ensure product stability and reliable delivery schedules. Smart Logistics Management: Utilizes information systems for full-process tracking, improving delivery efficiency and transparency. Professional Technical Support: Offers product selection advice, application consulting, and after-sales maintenance to ensure smooth project execution. Commitment to Sustainability: Prioritizes eco-friendly materials and energy-efficient products, fulfilling corporate social responsibility. Wone is committed to building an efficient, reliable, and sustainable supply chain for transformer accessories, supporting the stable development of the power industry.
Main Categories
Electrical fittings
Business Type
Design/Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Documents
Restricted.
transformer parts selection manual
White paper English
Consulting
Related Products
Related Knowledges
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Meter reading, verification, and billing are critical operations for power companies, and their efficiency directly impacts the company's sustainable development. In recent years, with the widespread adoption of intelligent technologies, smart meters have been promoted and applied in power companies, driving transformation in meter reading and billing operations. The integrated application of smart meters and meter reading, verification, and billing information systems has become a key developme
Echo
09/01/2025
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!