Vertical Vee Switch Unitized

  • Vertical Vee Switch Unitized

Key attributes

Brand ROCKWILL
Model NO. Vertical Vee Switch Unitized
Rated voltage 36kV
Rated normal current 2000A
Series AVRVU

Product descriptions from the supplier

Description

The Vertical Vee Switch Unitized is a high-voltage switching device with a double-column V-type structure design. It is mainly used for circuit switching and electrical isolation under no-load conditions in power systems, and has significant advantages especially in scenarios such as wind power and substations.

Features:

  • Fully Compliant with ANSI/IEEE C37.30.1

  • Vertical Break Operation

  • Fully Assembled and adjusted prior to shipment for quick installation

  • 8.3kV – 245kV

  • 1200A – 3000A

  • Rotating Blade MechanisN

  • Reverse Loop Contacts

  • Laminated Shunt Hinge

  • Double Row Stainless Steel Bearing

  • Compatible with Turner TECORupter Interrupter Attachments

FAQ
Q: What are the interlocking regulations for bypass disconnectors in thermal power plants and substations?
A:
 The interlocking regulations for bypass disconnectors in thermal power plants and substations are as follows:
  • The bypass disconnector of each line can only be operated when the bypass circuit breaker is open and its bypass bus disconnector is closed. For the operation of the line bypass disconnector, it can only be operated when its outgoing line earthing switch is open.
  • The bypass bus-side disconnector of the bypass circuit breaker can only be operated when the bypass circuit breaker is open and the disconnector connected for bus tie operation is open.
  • The earthing switch on the bypass bus side of the bypass circuit can only be operated when the disconnector on the bypass bus side of the bypass circuit breaker is open.
  • The earthing switch on the bypass circuit breaker side of the bypass circuit can only be operated when the bypass circuit breaker and its bypass bus-side disconnector are open, and the disconnector connected for bus tie operation is open.
Q: How to Select Suitable Disconnectors Based on Altitude?
A:

In high-altitude areas, due to thin air, insulation distances need to be appropriately increased. Therefore, the following points should be considered during selection:

  • Rockwill Electric: DS7B-800D/5000, custom-designed for high-altitude applications, offers strong corrosion resistance and durability, adapts to complex outdoor environments, and features user-friendly operation with reliable safety interlock design.

  • Pinggao Electric: GW46-1100/6300, an ultra-high voltage (UHV) level product capable of providing sufficient insulation margin.

  • China XD Electric: GW47-1100/6300, also suitable for UHV environments and tested for plateau adaptability.

  • Siyuan Electric: GW5-G-252D/2000, though not at the UHV level, its improved design enhances performance under high-altitude conditions.

Comparison Points:

  • Insulation Distance: UHV-level models like GW46 and GW47 provide larger insulation distances, making them more suitable for high-altitude applications.

  • Altitude Correction: For non-UHV level products, it is necessary to refer to the altitude correction factors of specific models to ensure compliance with on-site conditions.

 
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.