Transformers for dry shore power supply

  • Transformers for dry shore power supply

Key attributes

Brand ROCKWILL
Model NO. Transformers for dry shore power supply
Rated voltage 35kV
Rated frequency 50/60Hz
Rated capacity 1250kVA
Series SGN

Product descriptions from the supplier

Description

Product Overview

Through the Y/△ wiring principle, the isolation transformer can block part of the harmonic output and reduce the interference signal, prevent the current distortion of nonlinear loads from affecting the normal production of AC power supply and pollution to the power grid, and play a role in purifying the power grid.

Applications:shipping

Feature

  • Reduce ship generators, achieve energy conservation and emission reduction:In recent years, our company's isolation and voltage regulating transformers have been used in shore power supply equipment. The shore power supply system refers to a ship power supply mode where ships stop using their on-board generators and switch to land-based power supply when berthing at ports. This reduces the use of ship generators and exhaust emissions, achieving the goal of replacing oil with electricity, saving energy and reducing emissions.

  • Small size, low loss, easy to transport:The transformers produced by our company for shore power supplies feature small size, low loss, low noise, no pollution, maintenance-free operation, flame retardancy and fire resistance, making them easy to transport. The coils adopt special craftsmanship to enhance resistance to salt spray and moisture, improving operational reliability. Meanwhile, all metal components meet or exceed C4 anti-corrosion standards, giving them strong adaptability to marine environments.

Basic parameters

Note: The above are general parameters, if there are different parameter requirements, they can be customized!

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Implementation Scheme for Installing Lightning Arresters or Voltage Transformers in Gas-Insulated Ring Main Units
    According to insulation type, ring main units (RMUs) can be categorized as gas-insulated or air-insulated. The former installs primary circuit components in a sealed metal enclosure filled with low-pressure gas (primarily SF₆ or mixed gases) as the insulating medium, using cable terminals for incoming and outgoing lines. Due to superior insulation, compact size, and modular design, they are widely used in 10kV outdoor distribution substations and prefabricated transformer stations. However, thei
    08/16/2025
  • High-Temperature Insulating Material Solution for Electric Furnace Transformers
    Background & Challenge​Electric furnaces operate for extended periods under harsh conditions involving high temperatures, dust, etc. Traditional transformer insulation materials experience accelerated aging in these environments, leading to insulation failure, reduced lifespan, and even unplanned furnace shutdowns, significantly impacting production efficiency.​Core Strategy​Implement a dual-pronged approach to ensure transformer reliability and long-term operation under extreme high tempera
    08/09/2025
  • Dynamic Reactive Power Compensation Solution for Electric Furnace Transformers
    Dynamic Reactive Power Compensation Solution for Electric Furnace Transformers​Electric furnaces (particularly arc furnaces and submerged arc furnaces) exhibit significant ​shock load characteristics​ during smelting processes, causing ​severe power factor fluctuations (typically between 0.6 and 0.8)​. This not only leads to grid voltage fluctuations, flicker, and harmonic pollution but also increases line losses and reduces grid power supply efficiency.To address this challenge, this solution e
    08/09/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.