• TM&TMY Series Copper Busbar
TM&TMY Series Copper Busbar
discuss personally
Model
CALC-1
Basic info
Brand Wone
Model NO. Customized Copper-aluminum Composite Strip/Bar/Plate EXW/FOB/CIF
Thickness 2.24-50mm
Width 16-400mm
Series TM&TMY
Product Detail

Product application

Product application: Apply to electrical engineering like high/low voltage clectrical appliances, switch contact, power distribution equipment, bus duct and larg current electrolysis refining project like mental smelting petrochemical.

Operative Norm

GB/T5585.1-2005 Electrical copper busbar.

Type and Chemical composition

1721696966589_修复后.png

  • Section shapes of copper busbar: circular bead, round edge, all round edge.

    1721697362146.png

  • a-Thickness is the narrow side dimension mm; b-Thickness is width dimension mm; r -Rounded Corenur Rounded edge radius mm.

Thickness deviation 

1721697772702_修复后.png


Width deviation
1721697614092_修复后.png

Physical property

1721697834041_修复后.png

Q: What kind of material is copper bus? 

A: Copper busbar is a high-current conductive product made of copper. It is usually rectangular or circular long strip, with high purity copper material, copper conductivity is good, which makes the copper bus can carry a large current. 

Q: Where is the copper bus mainly used? 

A: It is widely used in power facilities such as substations and distribution rooms. For example, in substations, it is used to connect transformers, switchgear and other equipment, which can effectively distribute and transmit electric energy. It is also indispensable in the electrical system of large factories, which can distribute electrical energy to various workshops or large equipment. 

Q: What are the advantages of copper bus bars?

A: It has many advantages, first of all, strong conductivity, can reduce power loss. Secondly, its mechanical strength is relatively high, and it can withstand certain mechanical stresses. Moreover, the processing performance of the copper busbar is good, and the processing operations such as cutting and bending can be carried out according to the actual needs.

Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!