Three phase oil immersed shunt reactor

  • Three phase oil immersed shunt reactor

Key attributes

Brand POWERTECH
Model NO. Three phase oil immersed shunt reactor
Rated voltage 66kV
Rated frequency 50/60Hz
Series Three phase oil immersed shunt reactor

Product descriptions from the supplier

Description

Product overview
Three phase oil immersed shunt reactor is mainly used as high-voltage transformer to limit short-circuit current, stabilize voltage, reactive power compensation and shift.

  • Main application fields: substation, user distribution station and other 66kV and below power systems.

  • Executive standard: iec60076.

Ordering instructions

  • Main parameters of transformer (voltage, capacity, loss and other main parameters)

  • Service environment of transformer (altitude, temperature, humidity, place, etc.)

  • Other customized requirements (tap changer, color, conservator, etc.)

  • Minimum order quantity: 1 set, global delivery within 7 days.

  • The normal delivery cycle is 30 days, and the goods can be delivered quickly all over the world.

Product superiority

Suitable for power systems at 66kV and below, with a rated capacity range of 3,000~80,000kvar, a noise level below 65dB, A-class insulation, and insulation level complying with GB1094.6 standard, for outdoor application. Widely applied in substations and user power distribution stations.
The oil-immersed iron-core reactor uses insulating oil as the insulating medium, consisting of an iron core, coils, and an oil tank. It features a compact size, low temperature rise, high insulation strength, and low noise and environmental impact. Compared to conventional oil-immersed iron-core shunt reactors, the oil-immersed delta-connected iron-core shunt reactor has a more balanced three-phase structure and lower additional losses and volume for the same capacity.

Product-related parameters

  • Rated capacity: 3,000~80,000kvar

  • Rated Voltage: 66kV and below

  • Noise Level: ≤65dB

  • Insulation class: A

  • Insulation level: complies with GB1094.6 standard

  • Application: outdoor

What are the cooling methods of the reactor?

Cooling Methods:

  • The cooling method for reactors depends on their capacity and the operating environment. There are several options available.

Natural Air Cooling:

  • Natural air cooling is suitable for small-capacity reactors. It relies on the natural convection of air around the reactor surface to dissipate heat.

Forced Air Cooling:

  • Forced air cooling uses fans to blow cool air over the reactor surface, enhancing heat dissipation efficiency. This method is appropriate for medium-capacity reactors.

Oil-Immersed Cooling:

  • For large-capacity reactors, oil-immersed cooling may be used. The reactor is submerged in insulating oil, which transfers heat through convection to a heat exchanger (radiator). The radiator then dissipates the heat into the surrounding environment.

Water Cooling:

  • Water cooling is another option, using water as the cooling medium. It offers higher cooling efficiency but requires stringent sealing and water quality standards for the equipment.


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 580000m² Total staff: Highest Annual Export(usD): 120000000
Workplace: 580000m²
Total staff:
Highest Annual Export(usD): 120000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • China Develops Largest 750kV 140Mvar Stepped-Controlled Reactor
    Chinese reactor manufacturer successfully completed all tests in one go for the nation’s largest-capacity 750 kV, 140 Mvar stepped-controlled shunt reactor developed for the Turpan–Bazhou–Kuche II Circuit 750 kV transmission and transformation project. The successful completion of these tests marks a new breakthrough in the core manufacturing technology of 750 kV reactors by the Chinese manufacturer, pioneers a new field for 750 kV stepped-controlled shunt reactors in China, and lays a solid fou
    12/01/2025
  • Technical Features Application and Standards of 500kV Dry-type Shunt Reactors in Brazil
    1 Technical Features and Standard References of 500kV Dry - type Shunt Reactors1.1 Technical FeaturesThe 500kV dry - type shunt reactor, an oil - free power device for ultra - high - voltage transmission systems, boasts core features like advanced insulation, innovative heat dissipation, optimized electromagnetic design, and modular structure. These advantages, outperforming traditional oil - immersed reactors, also drive new technical standard demands. Advanced Insulation: Using epoxy resin cas
    07/24/2025
  • Vibration Monitoring and Fault Diagnosis for High-Voltage Shunt Reactors
    1 Vibration Monitoring and Fault Diagnosis Technology for High - Voltage Shunt Reactors1.1 Measuring Point Layout StrategyVibration characteristic parameters (frequency, power, energy) of high - voltage shunt reactors are fully recorded in operation logs. For vibration analysis, focus on resolving the complexity of electric field distribution at winding ends. Quantitatively evaluate field - strength distribution under operating/lightning overvoltage and voltage gradient characteristics of longit
    07/24/2025
  • What is a Shunt Reactor?
    What is a Shunt Reactor?Shunt Reactor DefinitionA shunt reactor is defined as an electrical device used in high voltage power systems to stabilize voltage during load changes.Voltage StabilizationIt controls dynamic overvoltage and provides capacitive reactive power compensation in systems above 400kV.Impedance TypesShunt reactors come in gapped core or magnetically shielded air core types to maintain constant impedance and avoid harmonic currents.Loss Measurement MethodsLosses are measured at l
    07/30/2024
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.