• Single Phase Active Electronic Reactive Fcatory Electricity Meter
  • Single Phase Active Electronic Reactive Fcatory Electricity Meter
  • Single Phase Active Electronic Reactive Fcatory Electricity Meter
Single Phase Active Electronic Reactive Fcatory Electricity Meter
$90.00
Model
SRMA-230/5(60)-3
SRMA-230/5(100)-3
SRMA-230/5(80)-3
SRMA-230/5(50)-3
SRMA-230/5(40)-3
SRMA-230/5(30)-3
SRMA-230/5(30)-2
SRMA-230/5(40)-2
SRMA-230/5(50)-2
SRMA-230/5(80)-2
SRMA-230/5(100)-2
SRMA-230/5(60)-2
SRMA-230/5(60)-1
SRMA-230/5(100)-1
SRMA-230/5(80)-1
SRMA-230/5(50)-1
SRMA-230/5(45)-1
SRMA-230/5(40)-1
SRMA-230/5(32)-1
SRMA-230/5(30)-1
Basic info
Brand Wone
Model NO. Single Phase Active Electronic Reactive Fcatory Electricity Meter
Rated voltage 230V
Rated normal current 5(45)A
Rated frequency 50(Hz)
Methods of Communication RS485
Series D123031
Product Detail

Description

The meter cover and terminal cover are made of transparent PC materials, and the internal structure of the meter and the welding assembly process are all exposed to the user,which has higher requirements on the ability of the meter manufacturer. The meter case is designed with a programming key, which has a lead block. And the removal of the lead seal can press the programming button, which can set the parameters of the meter.

Features

  • Active and reactive energy measurement

  • Mounted mounting installation

  •  Can up to 60A. RS485.

  • IR and ZIGBEE communication.

  • Multi-tariff function.

  • Meter has 3.6V Lithium battery, which is used to support multi-tariff function. And the precision of RTC is better than 0.5s/day.

  • LCD backlight allows the meter to be read in low light conditions.

  • With relay internal,which is used to remote control the meter connect and disconnect.

  • Terminal cover open detection.

  • With events records.

  • Over or Low voltage protection.

  • Electricity larceny prevention.

  •  Reactive energy can be measured.

  •  Degree of Protection: IP51 (indoor meter).

Specifications

Main
Range D123031
Product or Componet Type Energy meter
Country of origin China
Complementary
Phase Single Phase
Type of measurement

----

Metering type

Measurement

Device Application

Energy Charge

Accuracy class Active power 1.0 
Rated Current 5(60)A

Rated Voltage

230V

Network Frequency 50Hz
Technology Type Electronic
Display Type LCD display(LCD 6+2 = 999999.99kWh)
Impulse Constant

3200imp/kWh(LED)   

Maximum value measured 99999.99kWh
Tariff input Multi-tariff
Communication port protocol ---
Communication port support RS485/IR /ZIGBEE
Local signalling

------

Number of inputs -------
Number of Outputs --------------
Output voltage 230V
Mounting Mode ---
Mounting Support -----
Connections - terminals

-------

Standards

IEC62052-11/IEC62053-21



Environment
IP degree of protection

IP51

Relative humidity ≤75%
Ambient air temperature for operation -20…65 °C
Ambient Air Temperature for Storage --20…65 °C
Operating altitude ---
Dimensions 120*173.5*55mm
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 57mm
Package 1 Width 175mm
Package 1 Length 122mm
Package 1 Weight 1.000kg



Connection Diagram


image.png


Dimensions


image.png









Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!