• Pluggable Communication Module Three-Phase YTL Energy Meter Device
  • Pluggable Communication Module Three-Phase YTL Energy Meter Device
  • Pluggable Communication Module Three-Phase YTL Energy Meter Device
Pluggable Communication Module Three-Phase YTL Energy Meter Device
$99.00
Model
TPM-220/5(60)
TPM-5(60)
TPM-360/5(80)
TPM-5(80)
TPM-220/5(100)
TPM-5(100)
Basic info
Brand Wone
Model NO. Pluggable Communication Module Three-Phase YTL Energy Meter Device
Rated voltage 3x120/208V
Rated normal current 0.25-5(60)A
Series D523090
Product Detail

Description

  • Anti-tampering

Support bypass detection, open cover detection, influence of external magnetic field, abnormal voltage record, live&neutral double circuit metering etc, totally 21 tampering situation detection.Two relays on phase wire&Neutral wire.

  • Tariff

Divide into weekday timetable and weekend timetable, with 10 time period and 10 tariffs. Every timetable has a backup table for remote updating of backup timetable and configure the switching time. Meter will automatically switch the tariff table at the switching time.

  • Event

Open cover, magnetic field, load ground connection, reserve current, over-voltage, low-voltage, low-frequency, overload,power-fail, low remaining power, and token record etc. Support 100 events。

  • Measurement

Meter measures voltage, current, active power, reactive power, frequency, power factor, MD in the current month, MD of last 1month, MD of last 2 month, the absolute value of total active energy, the absolute value of total active tariff energy, total input energy of the current month, total input energy of last 12 month, total output energy of the current month, total output energy of last 12 month, and total reactive energy.

  • Mode

Meter has 3 operation modes: STS token mode, currency prepaid mode and post-paid (traditional) mode, which can be switched. And the currency mode can be divided into tariff mode and step price mode. Modes can be configured through communication.

Specifications

Main
Range D523090
Product or Componet Type Smart Energy Meter
Country of origin China
Complementary
Phase Single Phase
Type of measurement

AC

Metering type

Measurement 

Device Application

Solar Power

Energy Charge

Accuracy class Active power 1.0 Reactive power 2.0
Rated Current 0,5-5(30)A,0,5-5(32)A,0,5-5(40)A,0,5-5(45)A,

0,5-5(50)A,0,5-5(60)A, 0,5-5(80)A

Rated Voltage

230V

Network Frequency 50-60Hz
Technology Type Electronic
Display Type LCD display(LCD5+1)
Impulse Constant

6400imp/kWh 6400imp/kvarh

Maximum value measured 99999.99kWh
Tariff input 10
Communication port protocol Modbus/GPRS/RF/G3PLC
Communication port support RS485 /GPRS/RF/G3PLC
Local signalling

------

Number of inputs -------
Number of Outputs --------------
Output voltage 230V
Mounting Mode suspension Mounting
Mounting Support -----
Connections - terminals

-------

Standards

IEC62052-11

IEC62053-21

IEC62053-31

IEC 62056-21 : DLMS/COSEM



Environment
IP degree of protection

IP54

outdoor, meter can work under 70 degree

Relative humidity 5…95 % 97 °F (36 °C)
Ambient air temperature for operation -40…70 °C
Ambient Air Temperature for Storage --40…70 °C
Operating altitude 4000 m
Dimensions 110mm*37mm*65mm
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 65mm
Package 1 Width 37mm
Package 1 Length 110mm
Package 1 Weight 1.000kg



Dimensions

1718257064328.jpg







Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!