Pluggable Communication Module Three-Phase YTL Energy Meter Device

  • Pluggable Communication Module Three-Phase YTL Energy Meter Device
  • Pluggable Communication Module Three-Phase YTL Energy Meter Device
  • Pluggable Communication Module Three-Phase YTL Energy Meter Device

Key attributes

Brand Wone
Model NO. Pluggable Communication Module Three-Phase YTL Energy Meter Device
Rated voltage 3x120/208V
Rated normal current 0.25-5(100)A
Series D523090

Product descriptions from the supplier

Description

Description

  • Anti-tampering

Support bypass detection, open cover detection, influence of external magnetic field, abnormal voltage record, live&neutral double circuit metering etc, totally 21 tampering situation detection.Two relays on phase wire&Neutral wire.

  • Tariff

Divide into weekday timetable and weekend timetable, with 10 time period and 10 tariffs. Every timetable has a backup table for remote updating of backup timetable and configure the switching time. Meter will automatically switch the tariff table at the switching time.

  • Event

Open cover, magnetic field, load ground connection, reserve current, over-voltage, low-voltage, low-frequency, overload,power-fail, low remaining power, and token record etc. Support 100 events。

  • Measurement

Meter measures voltage, current, active power, reactive power, frequency, power factor, MD in the current month, MD of last 1month, MD of last 2 month, the absolute value of total active energy, the absolute value of total active tariff energy, total input energy of the current month, total input energy of last 12 month, total output energy of the current month, total output energy of last 12 month, and total reactive energy.

  • Mode

Meter has 3 operation modes: STS token mode, currency prepaid mode and post-paid (traditional) mode, which can be switched. And the currency mode can be divided into tariff mode and step price mode. Modes can be configured through communication.

Specifications

Main
Range D523090
Product or Componet Type Smart Energy Meter
Country of origin China
Complementary
Phase Single Phase
Type of measurement

AC

Metering type

Measurement 

Device Application

Solar Power

Energy Charge

Accuracy class Active power 1.0 Reactive power 2.0
Rated Current 0,5-5(30)A,0,5-5(32)A,0,5-5(40)A,0,5-5(45)A,

0,5-5(50)A,0,5-5(60)A, 0,5-5(80)A

Rated Voltage

230V

Network Frequency 50-60Hz
Technology Type Electronic
Display Type LCD display(LCD5+1)
Impulse Constant

6400imp/kWh 6400imp/kvarh

Maximum value measured 99999.99kWh
Tariff input 10
Communication port protocol Modbus/GPRS/RF/G3PLC
Communication port support RS485 /GPRS/RF/G3PLC
Local signalling

------

Number of inputs -------
Number of Outputs --------------
Output voltage 230V
Mounting Mode suspension Mounting
Mounting Support -----
Connections - terminals

-------

Standards

IEC62052-11

IEC62053-21

IEC62053-31

IEC 62056-21 : DLMS/COSEM



Environment
IP degree of protection

IP54

outdoor, meter can work under 70 degree

Relative humidity 5…95 % 97 °F (36 °C)
Ambient air temperature for operation -40…70 °C
Ambient Air Temperature for Storage --40…70 °C
Operating altitude 4000 m
Dimensions 110mm*37mm*65mm
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 65mm
Package 1 Width 37mm
Package 1 Length 110mm
Package 1 Weight 1.000kg



Dimensions

1718257064328.jpg







Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 65666m²m² Total staff: 300+ Highest Annual Export(usD): 50000000
Workplace: 65666m²m²
Total staff: 300+
Highest Annual Export(usD): 50000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.