• Photovoltaic grid-connected isolation transformer
Photovoltaic grid-connected isolation transformer
discuss personally
Model
SGG-220kVA
SGG-180kVA
Basic info
Brand ROCKWILL
Model NO. Photovoltaic grid-connected isolation transformer
Rated frequency 50/60Hz
Rated capacity 180KVA
Series SGG
Product Detail

Product Overview:

Photovoltaic power generation inverter isolation transformers play a critical role in systems that harness solar energy via the photovoltaic effect at semiconductor interfaces, where solar cells serve as the core components. These cells are encapsulated and connected in series to form large-area modules, which, when integrated with power controllers, constitute a complete photovoltaic power generation device.

Designed primarily for solar inverter systems, photovoltaic transformers require high-efficiency performance to compensate for inherent energy conversion losses in photovoltaic setups. Their grid-side wiring configurations, such as Dyn11 and YD5 phase shift transformers with 120° phase displacement, ensure stable grid interconnection. To minimize no-load energy losses, these isolation transformers are typically operated during daylight hours and shut down at night.

Below are reference parameters for three-phase photovoltaic transformers:

Key Features:

  • Electrical Safety Isolation:Designed to achieve complete electrical separation between the photovoltaic system and the grid, preventing direct current (DC) leakage and reducing risks of electric shock. It blocks grid-borne harmonics and surges, ensuring clean power transmission.

  • Efficient Grid Compatibility:Supports standard grid connection configurations (e.g., Dyn11, YD5 with 120° phase shift) to match grid voltage and frequency requirements. Enables stable power inversion from DC (solar panels) to AC (grid), with conversion efficiency ≥98% to minimize energy loss.

  • Harmonic Suppression & Waveform Purity:Integrates low-loss core materials (e.g., oriented silicon steel) and foil winding technology to suppress 3rd harmonic distortion and maintain sine-wave output. Ensures compliance with grid power quality standards (e.g., IEEE 519) for reliable grid interconnection.

  • Adaptive Operation & Energy Savings:Features automatic daytime activation and nighttime shutdown to eliminate no-load losses. Suitable for off-grid/on-grid systems, with customizable capacity (5kVA–1000kVA) to match solar array scales.

  • Robust Environmental Adaptability:Constructed with weather-resistant enclosures (e.g., 304 stainless steel) for outdoor installations, resisting humidity, temperature fluctuations, and corrosion. Dry-type air cooling design ensures maintenance-free operation in harsh environments.

  • Customizable Design Flexibility:Supports voltage customization (input/output: 220V–1140V) and insulation classes (B/F/H) for diverse project needs. Compact structure fits limited space in solar power stations, with optional IP certifications for enhanced protection.

Technical data:

Conditions of Use. Working environment temperature: 15~+50℃

Operating ambient temperature:20—90%RH

Atmospheric pressure in the working environment:860 hpa---1060 hp2

Storage/transport temperature:20℃-- +55℃

Main technical features:

Rated capacity:5KVA—1000KVA

Input Voltage: Rated voltage 270V or 315V

Input current by actual voltage

Output voltage: Rated voltage: 380V or 400V

The output current is based on the actual voltage

Connection mode :dyn11

Efficiency :≤98.5%

Frequency: 50HZ/60HZ

Insulation resistance :25A less than 500MΩ

Induction withstand voltage :125HZ/800y/60

Insulation Chip Class :H (Temperature Resistance 180 °C)

Noise :≤30dB)

Temperature rise: ≤ allows for a temperature rise of 115k

Impedance Voltage Drop :≤4%

Structure: Forced air cooling, waiting for the temperature controller, according to customer requirements, reach a certain temperature, the fan will be automatically opened.

Degree of protection :IP00

Anti-interference mode: copper foil isolation shielding grounding:

Waveform Distortion No additional waveform distortion.

Electrical strength: Power frequency sinusoidal voltage 3000V, which lasts for one minute, without breakdown and flashover

Insulation resistance (input and output to ground) Test voltage at least 1000V DC insulation resistance greater than 1000MΩ

Overload capacity Twice the rated current for one minute.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Neutral line current is actually greater than live line current? Why?
Neutral line current is actually greater than live line current? Why?
In a three-phase four-wire power distribution system, it is a consensus among industry insiders that the neutral line current should be very small when the three-phase loads are balanced. However, more and more phenomena are subverting this concept.For example, the advertising light boxes around a building use fluorescent lighting with electronic ballasts. The loads on the three-phase lines are balanced, with each phase current being approximately 90A, but the neutral line current reaches 160A.I
RW Energy
08/01/2025
Difference Between EMF and Voltage
Difference Between EMF and Voltage
One of the key differences between electromotive force (EMF) and voltage is that EMF refers to the energy supplied to charges, while voltage represents the energy required to move a unit charge from one point to another. Other distinctions between the two are detailed in the comparison chart below.Comparison ChartDefinition of VoltageVoltage is defined as the energy required to move a unit charge from one point to another. It is measured in volts (V) and denoted by the symbolV. Voltage is induce
Dyson
08/01/2025
Case Analysis: Economy and Reliability of 110kV All-Aluminum Winding Power Transformers
Case Analysis: Economy and Reliability of 110kV All-Aluminum Winding Power Transformers
Currently, the market price of copper remains high, fluctuating in the range of 70,000 to 80,000 yuan per ton. In contrast, the price of aluminum stays low, lingering in the range of 18,000 to 20,000 yuan per ton. For power transformers, replacing copper windings with aluminum windings in design will undoubtedly significantly reduce the material cost of products, bringing substantial cost savings to end customers.For a long time, it has been widely believed in the industry that aluminum windings
Ron
08/01/2025
What should be done if the neutral line current is too large?
What should be done if the neutral line current is too large?
As we all know, if an electrical line exceeds its rated load, it will overheat severely, and may even cause a fire. For safety reasons, overcurrent protection devices are therefore installed on lines. Whenever the current in the line exceeds the rated value, the overcurrent protection device will automatically cut off the line to prevent fire. The "excessive neutral line current" mentioned here refers to the phenomenon where the neutral line current is excessively high (more than 1.5 times the p
RW Energy
08/01/2025
What does the lifting inspection of a transformer core include?
What does the lifting inspection of a transformer core include?
1.Environmental Requirements for Transformer Core-Lifting Inspection1.1 General Environmental ConditionsCore - lifting operations are preferably carried out indoors. For large transformers that have to be operated outdoors due to specific conditions, sufficient measures must be taken to prevent moisture and dust contamination.Core - lifting should not be conducted during rainy or snowy weather or when the relative humidity exceeds 75%.The ambient air temperature during core - lifting should not
Rockwell
08/01/2025
Transformer operation and maintenance
Transformer operation and maintenance
Transformer Operating TemperatureDuring operation, transformers generate copper losses and iron losses, both of which are converted into heat, causing the transformer’s temperature to rise. Most transformers in China use Class A insulation. Due to heat transfer characteristics, significant temperature differences exist between different components during operation: winding temperature is the highest, followed by the core, and then the temperature of the insulating oil (with upper-layer oil being
Encyclopedia
07/31/2025
×
Inquiry
Download