• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


380V/400V/415V/480V/6.3kV/10.5kV PERKINS series engines with the option of Stamford, Marathon or Leroy-Somer alternators

  • 380V/400V/415V/480V/6.3kV/10.5kV PERKINS series engines with the option of Stamford, Marathon or Leroy-Somer alternators

Key attributes

Brand Wone
Model NO. PERKINS series alternators
Prime power 320KW
Reserve power 308KW
Series PERKINS

Product descriptions from the supplier

Description

Description:

The PWP Series - uses PERKINS brand engines produced in China, with the option of Stamford, Marathon or Leroy-Somer alternators.

Voltage optional: 380V/400V/415V/480V/6.3kV/10.5kV (special voltage can be customized).

If you choose the 60HZ model, please contact us directly. we will provide you with the 60HZ model according to your requirements.

Technical parameters:

image.png

image.png

image.png

Remark:

  • All ratings are for reference only, please refer to the specific generator set technical data sheet for final power ratings.

  • All rating data are based on ISO 8528-1, 1SO 3046, DIN6271 operating under conditions using typical fan sizes and gear ratios. PAUWAY quotes a performance tolerance of ±5%.

  • Prime power = power under available load instead of the main grid. 10% overload is allowed for one hour of operation every 12 hours.

  • Standby power = power available under variable load in the event of a failure in the main grid, up to 500 hours per year. Overload is not allowed.

  • Rated power factor: 0.80.

  • N/A: Not available.

  • We reserves the right to change models, technical specifications, colors, configurations and accessories without prior notice. Please contact our sales team before ordering.

 What alternators are available for the series engines?

Stamford Alternators:

Stamford alternators are renowned for their efficient power generation performance and stable voltage output, making them an ideal match with Perkins engines to provide users with high-quality power supply. Their product range covers generators of various power and voltage ratings, meeting the needs of different application scenarios.

Marathon Alternators:

Famed for their exceptional reliability and durability, Marathon alternators employ advanced design and manufacturing processes to ensure stable performance during long-term operation. Marathon generators also feature excellent voltage regulation and interference resistance, providing reliable power support for sensitive equipment.

Leroy-Somer Alternators:

Leroy-Somer alternators are characterized by their efficiency, energy savings, and environmental friendliness. With unique electromagnetic designs and manufacturing techniques, these generators minimize energy loss during power generation, enhancing efficiency. Additionally, Leroy-Somer generators come equipped with comprehensive protection features and intelligent control systems, enabling remote monitoring and management of the generators.


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 65666m²m² Total staff: 300+ Highest Annual Export(usD): 50000000
Workplace: 65666m²m²
Total staff: 300+
Highest Annual Export(usD): 50000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.