• LXDC Current Transformer
LXDC Current Transformer
discuss personally
Model
LXDC-30/1
Basic info
Brand Wone Store
Model NO. LXDC Current Transformer
Rated frequency 50/60Hz
Power frequency withstand voltage 3kV
Rated current ratio 30/1
Series LXDC
Product Detail

Product Overview

Zero -Sequence Current transformer Match with signal equipment and protective relaying equipment when power system produce zero sequence earthing current,act the equipment components to realize protective or monitoring function.It adopts stainless steel metal shell and easy installation save much room,many specs' high accuracy zero sequence CT are power system(such as neutral earthing, big current earthing,small current earthing or arc suppression coil earthing)etc

Key Features

  • High-Precision Current Measurement:Adopting high-permeability silicon steel core, achieving accuracy class 0.2S with error ≤0.2% within 1%~120% of rated current, meeting high-precision requirements for energy metering devices. Secondary rated current supports 5A/1A options to adapt to different measuring equipment interfaces.
  • Wide-Range Adaptive Design:Current ratio ranges from 50/5 to 2000/5A, enabling flexible range switching via multi-tap design (e.g., dual ranges of 200/5A and 400/5A). With a dynamic response range of 1:100, it simultaneously satisfies normal load monitoring and large-current measurement during short-circuit faults.
  • Fully Enclosed Insulation Structure:Formed by vacuum-cast epoxy resin with IP65 protection rating, effectively resisting moisture, salt fog, and dust. Insulation materials comply with UL94 V-0 flame retardant grade, withstanding -40℃~+85℃ temperature range, suitable for harsh environments like outdoor substations and humid basements.
  • Anti-Saturation & Transient Response Characteristics:The core uses a special magnetic circuit design to avoid saturation under short-circuit current (20 times rated current), ensuring transient current waveform fidelity. 5P20-class protection windings meet rapid action requirements of relay protection devices, with action time ≤10ms.

Technical Data

  • Rated secondary current: 5A,1A
  • Power frequency withstand voltage:  3kV
  • Rated frequency: 50/60Hz
  • Installation site: Indoor
  • Technical standard: IEC 60044-1 (IEC 61869-1&2)

 

 

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!