• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


niskofrekventni online UPS napajanje (3fazni ulaz 1fazni izlaz)

  • low frequency on-line UPs power supply (3phase input 1phase output)

Ključni atributi

Marka Switchgear parts
Broj modela niskofrekventni online UPS napajanje (3fazni ulaz 1fazni izlaz)
Nominirana frekvencija 50/60Hz
Izlazni napon 405VDC/220VDC
Ulazni napon 380V
kapacitet 10kVA
Serija HBD

Opisi proizvoda od dobavljača

Opis

Značajke proizvoda

Inteligentna digitalna kontrolna tehnologija
Korištenje visokobrzih mikrokontrolera Intel i programabilnih logičkih uređaja za postizanje kontrole kruga, postavljanja parametara, upravljanja operacijama, napredne samodiagnostike i samoodobre funkcije. Može provoditi samodiagnosticu i analizu grešaka na svim neovisnim spojevima na ploči. Potpuno možete vjerovati transformiranom sinusoidnom naponu i novom rješenju za savršeno funkcioniranje kako biste zadovoljili vaše stvarne potrebe.
Učinkova IGBT (izolirani dvopolni tranzistor) inverterna tehnologija
IGBT ima odlične karakteristike brzog prekida; ima radne karakteristike visokog napona i struje; koristi pogon tipa napona, zahtijeva se samo mala snaga za upravljanje. Šesto generacije IGBT ima niži pad napona u zasićenju, veću učinkovitost invertora i veću pouzdanost.
Izvrste karakteristike opterećenja
Potpuno ispunjava prijelaz od 0 do 100% opterećenja bez prebacivanja na omazi, štiti stabilan i pouzdan izlaz.
Ljudsko usmjereni veliki LCD zaslon na kineskom i engleskom jeziku
Veliki zaslon prikazuje izbornik na kineskom i engleskom jeziku, s jasnim dijagramom toka koji pokazuje stanje rada, omogućujući fleksibilno implementiranje funkcija ljudskog strojnog dijaloga. Intuitivna LED indikacija stanja, stil rada indikacije stanja, jasno na prvi pogled.
Visoko performantne dinamičke karakteristike
Primjenjuju se višestruki povratni kontrole, poput trenutne kontrole i efektivne vrijednosti, kako bi se postigla visoka dinamička regulacija i smanjila distorzija izlaznog napona.
Potpuna funkcija zaštite
Višestruke funkcije zaštite i alarmiranja sustava, uključujući zaštitu od preopterećenja na ulazu/izlazu, zaštitu od talasa na ulazu, zaštitu faze, zaštitu od niskog napona baterije, zaštitu od preopterećenja na izlazu i zaštitu od visoke temperature.
Pametno upravljanje baterijom
Pametno punjenje baterije: automatsko prilagođavanje parametara punjenja baterije prema konfiguraciji baterije korisnika, a izvoditi konverziju ravnotežnog i plavajućeg punjenja, kompenzaciju temperature punjenja i opražnjavanja baterije prema okruženju snabdijevanja. Proširite životnu dobu baterije i smanjite teret administratora.
Primjena 6-pulsni (opcionalno 12 pulsi) pravilnik-punjač uz dodatak filtera harmonika na ulazu
Učinkovito suzbijanje harmonijskog zagađenja na ulazu, poboljšanje faktora snage na ulazu UPS-a i smanjenje harmonijskog struja na ulazu.
pametna nadzor
Komunikacijski priključci RS232 i RS485 omogućuju višesvrhsnu komunikaciju i daljinsku nadzor. Opcionalna SNMP kartica za daljinski nadzor i upravljanje mrežom; opcionalni suhi kontakt sučelje, koristi pasivne kontakte za nadzor stanja UPS-a.

Područje primjene
Prikladno za industrije kao što su financije, telekomunikacije, berza, porezi, promet, osiguranje, vlada, građevina, javno svjetlo, prometno svjetlo, elektroprivreda i rudarsko-geološki poduzeća.

Tehnički specifikacije

Model HBD-6KS HBD-10KS HBD-15KS HBD-20KS HBD-30KS HBD-40KS HBD-50KS HBD-60KS HBD-80KS
Nominal Capacity 6KVA 10KVA 15KVA 20KVA 30KVA 40KVA 50KVA 60KVA 80KVA
Working Mode and Principle Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology
AC Input                  
Phase Number Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G)
Input Nominal Voltage 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC
Input Voltage Range ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25%
Nominal Frequency 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10%
Voltage Harmonic Distortion <5% <5% <5% <5% <5% <5% <5% <5% <5%
Soft Start 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec
Battery (Maintenance-free Lead-acid Battery)                  
Nominal Voltage 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC
Quantity Unit 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series)
Charging                  
Maximum Output Voltage 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC
Float Voltage 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC)
Microcomputer-set Charging Current 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity)
AC Output                  
Rated Power (KW COSφ=0.8) Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8
Phase Number Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G)
Nominal Phase Voltage 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation)
Nominal Frequency 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply)
Frequency Stability: Asynchronous < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1%
Frequency Stability: Synchronous < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5%
Crest Factor 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1
Output Waveform Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave
Total Harmonic Distortion Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5%
Operating Temperature 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃
Relative Humidity 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation)
Operating Altitude < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters)
Options RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements
Dimensions (W×D×H) mm 390×659×860 430×760×1350 710×720×1450 710×850×1500 - - - 1100×860×1680 -
Main Unit Weight 150 199 220 305 380 480 566 590 986

Napomena: Model s ugrađenom baterijom i specifičnim zahtjevima za naponski nivo može se prilagoditi stvarnoj situaciji korisnika, a posebna ponuda će biti dostupna.

ČPP za
Q: Kako riješiti uobičajene greške ove UPS jedinice?
A:

① Alarm nadopterećenia: Wyłącz nieistotne obciążenia jednofazowe, lub zastąp UPS o większej pojemności; ② Alarm utraty fazy: Sprawdź połączenia wejściowe trójfazowe, napraw luźne lub odłączone przewody; ③ Alarm niskiego napięcia baterii: Ładuj ciągle przez 12 godzin, zastąp zestarzałe baterie, jeśli alarm nadal występuje; ④ Nieprawidłowe napięcie wyjściowe: Sprawdź połączenia wyjściowe, zresetuj UPS (odłącz zasilanie i ponownie włącz po 5 minutach); ⑤ Przegrzewanie transformatora: Natychmiast zatrzymaj korzystanie, sprawdź wentylację i obciążenie, skontaktuj się z serwisem po-gwarancyjnym.

Q: Koja je osnovna funkcija i načelo rada UPS-a s trofaznim ulazom i jednofaznim izlazom niskog frekvencijskog on-line tipa
A:

Njegova osnovna funkcija je pretvoriti trofazni glavni strujni tok u stabilan jednofazni strujni tok, osiguravajući neprekinuti, čist strujni tok za kritične jednofazne opterećenja, dok se rješavaju problemi s glavnim strujnim tokom poput fluktuacije napona, harmonijskih interferencija i prekida struje. Načelo rada: Uvođenje dvostruke pretvorbe (AC-DC-AC) + nizko-frekventni transformator dizajn. Kada je glavni strujni tok normalan, trofazni AC se pretvara u DC kako bi se nabijala baterija, zatim se DC pretvara u jednofazni čisti sinusni val AC za snabdijevanje opterećenja; kada glavni strujni tok pada, prelazi na baterijsku struju s vremenom prelaska od 0ms,

Upoznajte svog dobavljača
Online trgovina
Stopničasta stopa isporuke
Vrijeme odziva
100.0%
≤4h
Pregled tvrtke
Radno mjesto: 1000m² Ukupno osoblje: Najveći godišnji izvoz (USD): 300000000
Radno mjesto: 1000m²
Ukupno osoblje:
Najveći godišnji izvoz (USD): 300000000
Usluge
Vrsta posla: Prodaja
Glavne kategorije: Oprema za uređaje/Opravna uređaja/Visoki napon uređaji/Niskonaponski uređaji/Instrumenti i mjernih uređaja/Proizvodna oprema/Električne armature
Upravitelj doživotne jamstvene osiguranja
Usluge upravljanja brinući se o opremi tijekom cijelog vijeka trajanja, od nabave do korištenja, održavanja i posloprodajnog servisa, osiguravajući sigurno funkcioniranje električne opreme, kontinuiranu kontrolu i bezbrižnu potrošnju električne energije
Dobavljač opreme prošao je certifikaciju kvalifikacije platforme i tehničku evaluaciju, osiguravajući sukladnost, profesionalnost i pouzdanost od izvora

Povezani proizvodi

Povezane znanje

  • Glavni transformator Nesanice i Problemi s radom na plinu
    1. Zapis o nesreći (19. ožujak 2019.)U 16:13 sati 19. ožujka 2019., nadzorno okruženje prijavilo je rad s laganim plinom na glavnom transformatoru broj 3. U skladu s Pravilnikom o rukovanju električnim transformatorima (DL/T572-2010), osoblje za održavanje i eksploataciju (O&M) provjerilo je stanje na mjestu glavnog transformatora broj 3.Potvrđeno na mjestu: Na ploči neelektrične zaštite WBH glavnog transformatora broj 3 prijavljen je rad s laganim plinom faze B tijela transformatora, a rese
    02/05/2026
  • Kvarovi i otklanjanje kvarova u jednofaznom zemljanju na distribucijskim crtamа od 10kV
    Karakteristike i uređaji za otkrivanje jednofaznih zemljnih kvarova1. Karakteristike jednofaznih zemljnih kvarovaCentralni signalni alarmi:Zvoni upozornjenja i upaljuje se indikatorska lampica s natpisom „Zemljni kvar na [X] kV sabirnici odjeljka [Y]“. U sustavima s uzemljenjem neutralne točke pomoću Petersenove zavojnice (zavojnice za gašenje luka), također se upaljuje indikator „Petersenova zavojnica u radu“.Indikacije voltmetra za nadzor izolacije:Napon kvarne faze smanjuje se (u slučaju nepo
    01/30/2026
  • Neutralni način rada zemljanja središnje točke transformatora za mreže od 110kV~220kV
    Raspored operativnih načina zemljanja neutralne točke transformatora za mrežu od 110kV do 220kV treba zadovoljiti zahtjeve održivosti izolacije neutralne točke transformatora, te se treba pokušati održati nultu rednu impedanciju pretvorbe gotovo nepromijenjenu, osiguravajući da ukupna nulta redna impedancija u bilo kojoj točki prekida u sustavu ne prelazi tri puta ukupnu pozitivnu rednu impedanciju.Za transformatore od 220kV i 110kV u novim građevinama i projektima tehničke rekonstrukcije, njiho
    01/29/2026
  • Zašto se u pretvorima koriste kamenje šljunak kamenčići i drobljen stijena
    Zašto se u pretvorima koriste kamenje, šljunk, kamenčići i drobljeni kamen?U pretvorima, oprema poput transformatora snage i distribucije, prijenosnih linija, transformatora napona, transformatora struje i prekidača za odjednom sve zahtijevaju zemljanje. Osim zemljanja, sada ćemo detaljnije istražiti zašto se u pretvorima često koristi šljunk i drobljeni kamen. Iako oni izgledaju obično, ovi kameni igraju ključnu ulogu u pitanju sigurnosti i funkcionalnosti.U dizajnu zemljanja u pretvorima - pos
    01/29/2026
  • Zašto se jezgra transformatora smije zemljiti samo na jednoj točki Neću li više točaka zemljitvenja biti pouzdanije
    Zašto je potrebno zemljište transformatora?Tijekom rada, jezgra transformatora, zajedno s metalnim strukturama, dijelovima i komponentama koje fiksiraju jezgru i zavojnice, nalaze se u jakom električnom polju. Pod utjecajem tog električnog polja, stječu relativno visok potencijal u odnosu na zemlju. Ako jezgra nije zemljena, postojat će razlika u potencijalu između jezgre i zemljenih pričvršćujućih struktura i rezervoara, što može dovesti do intermitentnog iskra.Dodatno, tijekom rada, jako magne
    01/29/2026
  • Razumijevanje neutralnog zemljanja transformatora
    I. Što je neutralna točka?U transformatorima i generatorima, neutralna točka je specifična točka u vijku gdje je apsolutno napon između te točke i svakog vanjskog terminala jednak. Na dijagramu ispod, točkaOpredstavlja neutralnu točku.II. Zašto se neutralna točka mora zemljiti?Električni način povezivanja između neutralne točke i tla u trofaznom strujnom sustavu naziva semetoda zemljenja neutralne točke. Ova metoda direktno utječe na:Sigurnost, pouzdanost i ekonomiju mreže struje;Odabir razina i
    01/29/2026
Još uvijek niste pronašli odgovarajućeg dobavljača Pustite verificirane dobavljače da vas pronađu Dobijte ponudu odmah
Još uvijek niste pronašli odgovarajućeg dobavljača Pustite verificirane dobavljače da vas pronađu
Dobijte ponudu odmah
Pošalji upit
+86
Kliknite za učitavanje datoteke
Preuzmi
Dohvati IEE Business aplikaciju
Koristite IEE-Business aplikaciju za pronalaženje opreme, dobivanje rješenja, povezivanje s stručnjacima i sudjelovanje u suradnji u industriji u bilo koje vrijeme i na bilo kojem mjestu što potpuno podržava razvoj vaših projekata i poslovanja u energetici