sumber daya listrik UPS online frekuensi rendah (input 3 fasa output 1 fasa)

  • low frequency on-line UPs power supply (3phase input 1phase output)

Atribut Kunci

Merek Switchgear parts
Nomor Model sumber daya listrik UPS online frekuensi rendah (input 3 fasa output 1 fasa)
Frekuensi nominal 50/60Hz
Tegangan keluaran 405VDC/220VDC
Tegangan masukan 380V
Kapasitas 6kVA
Seri HBD

Deskripsi Produk dari Pemasok

Deskripsi

Fitur Produk

Teknologi kontrol digital cerdas
Menggunakan mikrokontroler kecepatan tinggi Intel dan perangkat logika pemrograman untuk mencapai kontrol sirkuit, pengaturan parameter, manajemen operasi, fungsi pemeriksaan diri canggih dan deteksi diri, dapat melakukan pemeriksaan diri dan analisis kesalahan pada semua koneksi sirkuit independen di papan sirkuit. Anda dapat sepenuhnya mempercayai tegangan sinus yang telah ditransformasikan secara digital dan solusi baru untuk operasi sempurna untuk memenuhi kebutuhan Anda.
Teknologi inverter IGBT (Insulated Gate Bipolar Transistor) yang efisien
IGBT memiliki karakteristik beralih kecepatan tinggi yang luar biasa; Memiliki karakteristik kerja tekanan tinggi dan arus tinggi; Menggunakan drive tipe tegangan, hanya diperlukan daya kontrol kecil. Generasi keenam IGBT memiliki penurunan tegangan jenuh yang lebih rendah, efisiensi inverter yang lebih tinggi, dan keandalan yang lebih tinggi.
Karakteristik beban unggul
Sesuai sepenuhnya dengan transisi dari 0 hingga 100% beban tanpa beralih ke bypass, dan melindungi output yang stabil dan andal.
Tampilan LCD besar berbahasa Cina dan Inggris yang ramah manusia
Layar besar menampilkan menu dalam bahasa Cina dan Inggris, dengan diagram alir yang jelas menunjukkan status operasional, memungkinkan pelaksanaan fleksibel fungsi dialog antara manusia dan mesin. Indikasi status LED intuitif, indikasi status gaya alur kerja, jelas sekilas.
Karakteristik dinamis performa tinggi
Adopsi beberapa kontrol umpan balik seperti kontrol instan dan nilai efektif untuk mencapai regulasi dinamis tinggi dan mengurangi distorsi tegangan output.
Fungsi perlindungan lengkap
Banyak fungsi perlindungan sistem dan alarm, termasuk perlindungan overvoltage input/output, perlindungan lonjakan input, perlindungan urutan fase, perlindungan tegangan rendah baterai, perlindungan overvoltage output, dan perlindungan suhu tinggi.
Manajemen baterai cerdas
Pengisian baterai cerdas: Secara otomatis menyesuaikan parameter pengisian baterai sesuai dengan konfigurasi baterai pengguna, dan melakukan konversi pengisian seimbang dan pengapungan, pengisian dan pengelolaan pembuangan kompensasi suhu pada baterai sesuai dengan lingkungan pasokan daya. Perpanjang umur baterai dan kurangi beban administrator.
Mengadopsi charger rectifier 6-pulse (opsional 12 pulse) sambil menambahkan filter harmonisa input
Efektif menekan polusi harmonisa input, meningkatkan faktor daya input pasokan daya UPS, dan mengurangi arus harmonisa input.
pemantauan cerdas
Port komunikasi RS232 dan RS485 benar-benar memungkinkan komunikasi multipurpose dan pemantauan jarak jauh. Kartu SNMP opsional untuk pemantauan jarak jauh dan manajemen jaringan; Interface kontak kering opsional, menggunakan kontak pasif untuk memantau status UPS.

Bidang Aplikasi
Cocok untuk industri seperti keuangan, telekomunikasi, sekuritas, pajak, transportasi, asuransi, pemerintah, penerangan bangunan, penerangan lalu lintas jalan, listrik, dan perusahaan pertambangan dan industri.

Spesifikasi Teknis

Model HBD-6KS HBD-10KS HBD-15KS HBD-20KS HBD-30KS HBD-40KS HBD-50KS HBD-60KS HBD-80KS
Nominal Capacity 6KVA 10KVA 15KVA 20KVA 30KVA 40KVA 50KVA 60KVA 80KVA
Working Mode and Principle Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology
AC Input                  
Phase Number Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G)
Input Nominal Voltage 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC
Input Voltage Range ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25%
Nominal Frequency 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10%
Voltage Harmonic Distortion <5% <5% <5% <5% <5% <5% <5% <5% <5%
Soft Start 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec
Battery (Maintenance-free Lead-acid Battery)                  
Nominal Voltage 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC
Quantity Unit 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series)
Charging                  
Maximum Output Voltage 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC
Float Voltage 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC)
Microcomputer-set Charging Current 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity)
AC Output                  
Rated Power (KW COSφ=0.8) Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8
Phase Number Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G)
Nominal Phase Voltage 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation)
Nominal Frequency 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply)
Frequency Stability: Asynchronous < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1%
Frequency Stability: Synchronous < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5%
Crest Factor 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1
Output Waveform Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave
Total Harmonic Distortion Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5%
Operating Temperature 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃
Relative Humidity 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation)
Operating Altitude < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters)
Options RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements
Dimensions (W×D×H) mm 390×659×860 430×760×1350 710×720×1450 710×850×1500 - - - 1100×860×1680 -
Main Unit Weight 150 199 220 305 380 480 566 590 986

Catatan: Model dengan baterai terintegrasi dan persyaratan voltase khusus dapat disesuaikan sesuai situasi aktual pengguna, dan penawaran harga terpisah akan diberikan.

FAQ untuk
Q: Bagaimana menangani kerusakan umum dari UPS ini?
A:

① Alarm overload: Cabut beban fase tunggal yang tidak penting, atau ganti dengan IEE-Business kapasitas lebih besar; ② Alarm hilang fase: Periksa kabel input 3-fase, perbaiki kabel yang longgar atau terputus; ③ Alarm baterai rendah: Charge secara terus-menerus selama 12 jam, ganti baterai yang sudah tua jika alarm tetap berlanjut; ④ Tegangan output abnormal: Periksa kabel output, reset IEE-Business (putuskan daya dan restart setelah 5 menit); ⑤ Transformator overheat: Berhenti menggunakan segera, periksa ventilasi dan beban, hubungi layanan purna jual untuk perawatan.

Q: Apa fungsi inti dan prinsip kerja UPS online frekuensi rendah 3-fase input 1-fase output
A:

Fungsi intinya adalah mengubah arus listrik utama 3-fase menjadi arus listrik stabil 1-fase, menyediakan pasokan daya yang tidak terputus dan murni untuk beban kritis 1-fase sambil memecahkan masalah jaringan seperti fluktuasi tegangan, gangguan harmonis, dan pemadaman. Prinsip kerja: Mengadopsi konversi ganda (AC-DC-AC) + desain transformator frekuensi rendah. Ketika jaringan normal, AC 3-fase diubah menjadi DC untuk mengisi baterai, kemudian DC diubah menjadi AC 1-fase gelombang sinus murni untuk pasokan beban; ketika jaringan gagal, ia beralih ke daya baterai dengan waktu transfer 0ms,

Kenali Pemasok Anda
Toko online
Tingkat pengiriman tepat waktu
Waktu Tanggapan
100.0%
≤4h
Tinjauan Perusahaan
Tempat Kerja: 1000m² Total karyawan: Ekspor Tertinggi Tahunan USD: 300000000
Tempat Kerja: 1000m²
Total karyawan:
Ekspor Tertinggi Tahunan USD: 300000000
Layanan
Jenis Bisnis: Penjualan
Kategori Utama: Suku Cadang Perangkat/Peralatan Pemeriksaan/Perangkat Listrik Tekanan Tinggi/Perangkat Listrik Rendah Tegangan/Alat ukur/Peralatan Produksi/Alat Pelindung Listrik
Manajer Jaminan Seumur Hidup
Layanan manajemen perawatan seumur hidup untuk pengadaan, penggunaan, pemeliharaan, dan purna jual peralatan, memastikan operasi aman peralatan listrik, kontrol berkelanjutan, dan konsumsi listrik tanpa khawatir
Pemasok peralatan telah lulus sertifikasi kualifikasi platform dan evaluasi teknis, memastikan kepatuhan, profesionalisme, dan keandalan dari sumbernya.

Produk Terkait

Pengetahuan Terkait

  • Kecelakaan Trafo Utama dan Masalah Operasi Gas Ringan
    1. Catatan Kecelakaan (19 Maret 2019)Pada pukul 16:13 tanggal 19 Maret 2019, latar belakang pemantauan melaporkan tindakan gas ringan pada trafo utama No. 3. Sesuai dengan Kode Operasi Trafo Listrik (DL/T572-2010), petugas operasi dan pemeliharaan (O&M) memeriksa kondisi di lapangan dari trafo utama No. 3.Konfirmasi di lapangan: Panel perlindungan non-elektrik WBH dari trafo utama No. 3 melaporkan tindakan gas ringan Fase B pada badan trafo, dan reset tidak efektif. Petugas O&M memeriksa
    02/05/2026
  • Kerusakan dan Penanganan Pembumian Satu Fase pada Jalur Distribusi 10kV
    Karakteristik dan Perangkat Deteksi Gangguan Tanah Fase-Tunggal1. Karakteristik Gangguan Tanah Fase-TunggalSinyal Alarm Sentral:Bel peringatan berbunyi, dan lampu indikator bertuliskan “Gangguan Tanah pada Seksi Bus [X] kV [Y]” menyala. Pada sistem dengan titik netral yang dihubungkan ke tanah melalui kumparan Petersen (kumparan peredam busur), indikator “Kumparan Petersen Beroperasi” juga menyala.Indikasi Voltmeter Pemantau Isolasi:Tegangan pada fasa yang mengalami gangg
    01/30/2026
  • Mode operasi grounding titik netral untuk transformator jaringan listrik 110kV~220kV
    Penataan mode operasi grounding titik netral untuk transformator jaringan listrik 110kV~220kV harus memenuhi persyaratan tahanan isolasi titik netral transformator, dan juga berusaha menjaga impedansi nol substasiun tetap hampir tidak berubah, sambil memastikan bahwa impedansi nol total pada setiap titik pendek di sistem tidak melebihi tiga kali impedansi positif total.Untuk transformator 220kV dan 110kV dalam proyek konstruksi baru dan renovasi teknis, modus grounding titik netralnya harus seca
    01/29/2026
  • Mengapa Stasiun Listrik Menggunakan Batu Krikil Kerikil dan Batu Pecah
    Mengapa Gardu Induk Menggunakan Batu, Kerikil, Kerakal, dan Batu Pecah?Di gardu induk, peralatan seperti trafo daya dan trafo distribusi, saluran transmisi, trafo tegangan, trafo arus, serta saklar pemutus semuanya memerlukan pentanahan. Selain pentanahan, kita kini akan membahas secara mendalam mengapa kerikil dan batu pecah umum digunakan di gardu induk. Meskipun tampak biasa, batu-batu ini memainkan peran kritis dalam keselamatan dan fungsi operasional.Dalam desain sistem pentanahan gardu ind
    01/29/2026
  • Mengapa Inti Transformator Harus Di-grounding di Satu Titik Saja Tidakkah Grounding Multi-Titik Lebih Andal
    Mengapa Inti Trafo Perlu Di-ground?Selama operasi, inti trafo, bersama dengan struktur logam, bagian, dan komponen yang memperbaiki inti dan gulungan, semuanya berada dalam medan listrik yang kuat. Dalam pengaruh medan listrik ini, mereka mendapatkan potensial yang relatif tinggi terhadap tanah. Jika inti tidak di-ground, perbedaan potensial akan ada antara inti dan struktur klem yang diground serta tangki, yang mungkin menyebabkan penyalaan intermiten.Selain itu, selama operasi, medan magnet ya
    01/29/2026
  • Memahami Penyambungan Netral Trafo
    I. Apa itu Titik Netral?Dalam transformator dan generator, titik netral adalah titik tertentu dalam lilitan di mana tegangan absolut antara titik ini dan setiap terminal eksternal adalah sama. Dalam diagram di bawah, titikOmewakili titik netral.II. Mengapa Titik Netral Perlu Di-grounding?Metode koneksi listrik antara titik netral dan tanah dalam sistem tenaga tiga fasa AC disebutmetode grounding netral. Metode grounding ini secara langsung mempengaruhi:Keamanan, keandalan, dan ekonomi jaringan l
    01/29/2026
Belum menemukan pemasok yang tepat Biarkan pemasok terverifikasi mencari Anda Dapatkan Penawaran Sekarang
Belum menemukan pemasok yang tepat Biarkan pemasok terverifikasi mencari Anda
Dapatkan Penawaran Sekarang
Pertanyaan
+86
Klik untuk mengunggah file
Unduh
Dapatkan Aplikasi Bisnis IEE-Business
Gunakan aplikasi IEE-Business untuk menemukan peralatan mendapatkan solusi terhubung dengan ahli dan berpartisipasi dalam kolaborasi industri kapan saja di mana saja mendukung sepenuhnya pengembangan proyek dan bisnis listrik Anda