Key attributes

Brand Wone Store
Model NO. LMZB-24 Outdoor Current Transformer
Rated voltage 22kV
Rated frequency 50/60Hz
Rated current ratio 500/5
Series LMZB

Product descriptions from the supplier

Description

Product Overview

LMZB-24 epoxy resin casting busbar type current transformer, is widely used outdoor for measuring current, electric energy and protective relaying in the electrical system with rated frequency 50Hz or 60Hz and highest voltage for equipment 24kV.  Rated primary current is 400-10000Aand rated secondary current is 5A or 1A.

Key Features

  • 24kV-Class Outdoor High-Voltage Adaptation Design:The LMZB1-24 outdoor current transformer features a 24kV rated voltage design with insulation levels reaching 75kV (lightning impulse) / 40kV (power frequency withstand voltage). It strictly complies with GB/T 4703.2 and IEC 60044-2 standards, and is optimized specifically for scenarios such as 20kV and below outdoor substations, ring main units, and cable distribution boxes. Its structural design fully accounts for the long-term operational requirements of high-voltage outdoor environments, effectively resisting voltage fluctuations and insulation aging, reducing the risk of equipment failures caused by insulation breakdown, and ensuring the stable operation of the power system.

  •  All-Climate Protection Structure:This product adopts a dual protective barrier composed of silicone rubber composite insulation material and a corrosion-resistant aluminum alloy shell: it has passed 7000 hours of UV aging testing, enabling it to withstand long-term outdoor exposure; it reaches IP68 protection level, allowing continuous operation at 1 meter underwater. Meanwhile, through a specially designed structure, it can resist snowfall of 20mm/h and ice loads of 10mm thickness. Verified by 2000 hours of salt spray testing, it has a creepage distance of 20mm/kV, making it suitable for various harsh outdoor environments such as coastal areas, high-altitude regions, and cold areas, and reducing the impact of climatic factors on equipment performance.

  • Dual-Winding High-Precision Measurement System:It integrates a 0.2S-class metering winding and a 5P20-class protection winding. The metering winding maintains a ratio error of ≤±0.2% within the range of 1%~120% rated current, meeting the requirements of high-precision electric energy metering and line loss analysis; the protection winding has a composite error of ≤5% under 20 times the rated current, with a response time of ≤10ms, which can quickly trigger relay protection devices to ensure safe disconnection in case of power grid faults. It is equipped with 2 sets of ratio taps (such as 300/5A, 600/5A), which can be adjusted through an outdoor sealed changeover switch, adapting to different load currents without disassembly, thus improving the flexibility of on-site application.

  • Enhanced Safety and Environmental Adaptability:It is built with a pressure balance valve to avoid shell condensation and air pressure deformation caused by temperature differences, and can be optionally equipped with explosion-proof certification (Ex d IIB T4), making it suitable for outdoor areas with flammable and explosive risks. Its anti-electromagnetic interference performance complies with IEC 61000-4-5 standards, and it can resist 60kA lightning strikes (10/350μs waveform). It maintains stable measurement accuracy even in strong electromagnetic environments, providing reliable current monitoring and protection guarantees for 20kV-class outdoor power grids.

Main technical parameter

  • Rated voltage: 20 kV or 22kV etc

  • Rated secondary current:5Aor1A

  • Rated insulation level: 24/50/125 kV

  • Standards: IEC60044-1.2003 Part 1: Instrument transformers-Part1: Current transformers or IEC61869-1&2-2012 etc.

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Outline

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Calibration Technology Challenges and Countermeasures for DC Electronic Current Transformers
    In modern power systems, DC electronic current transformers play a crucial role. They are not only used for high-precision current measurement but also serve as key tools for grid optimization, fault detection, and energy management. With the rapid development of high-voltage direct current (HVDC) transmission technology and its widespread deployment globally, the performance requirements for DC current transformers have become increasingly stringent, especially in terms of measurement accuracy
    07/23/2025
  • Performance Structure and Testing of Electronic Current Transformers
    1 Performance AdvantagesIn recent years, electronic current transformers (ECTs) have emerged as a key industry trend. National standards classify them into two types: Active Optical Current Transformers (AOCTs, active hybrid type) and Optical Current Transformers (OCTs, passive optical type). Active hybrid ECTs use low-power electromagnetic transformers and Rogowski coils as core sensing elements (Figure 1).Rogowski coils outperform traditional sensors with non-saturation and wide dynamic ranges
    07/22/2025
  • Principles Faults and Online Diagnosis of Electronic Current Transformer Secondary Circuits
    1 Principle and Role of Electronic Current Transformers1.1 Working Principle of ECTAn Electronic Current Transformer (ECT) is a key device for managing safe power system operations, converting large currents into manageable small-current signals for measurement and control. Unlike traditional transformers (relying on direct magnetic field interaction between primary and secondary windings), ECTs use sensors (e.g., Hall effect sensors) to detect magnetic field changes from the primary winding. Th
    07/22/2025
  • Key Technologies and Challenges of High-Voltage Electronic Transformers
    Traditional power transformers face inherent issues due to their sensors. Critically, they are vital for power plant monitoring, control, and protection (e.g., fault recording, safety control). However, large electrical energy transmission via information carriers and the lack of digital signal output from digital systems complicate secondary communication. Complex secondary wiring compensates for microcomputers’ high reliability, streamlining protection and secondary devices. This inn
    07/22/2025
  • What Are the Common Faults of Low-Voltage Voltage Transformers and Their Solutions?
    Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In low
    07/18/2025
  • Impact of Long-Term Immersion on Epoxy-Insulated Low-Voltage Current Transformers
    1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
    07/17/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.