• JDZW3-36 outdoor epoxy resin casting Voltage transformer
JDZW3-36 outdoor epoxy resin casting Voltage transformer
discuss personally
Model
JDZW3-36
Basic info
Brand Wone Store
Model NO. JDZW3-36 outdoor epoxy resin casting Voltage transformer
Rated frequency 50/60Hz
Primary voltage 35kV
Secondary voltage 110V
Series JDZW
Product Detail

Product Overview

JDZW3-36 voltage transformer, outdoor epoxy resin casting and double pole insulated VT, is widely used for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50Hz or 60Hz and insulation voltage 36 kV (Up to 40.5kV).

The iron core adopts advanced cold-rolled silicon steel sheet. High voltage outgoing line of primary winding was fetched out from top of the product; outgoing line of secondary winding was fetched out from transverse side of the product.

Key Features

  • Excellent Outdoor Insulation Protection:JDZW3-36 uses high-quality epoxy resin as the main insulation material, with a silicone rubber coating on the outer layer. The internal traditional epoxy resin casting process ensures the transformer's insulation and electrical performance. Silicone rubber features excellent arc resistance, hydrophobicity, and climatic adaptability, enabling the equipment to operate normally in high-altitude, high-salt fog, rainy, and strong UV environments. Even if system faults cause explosions, the external silicone rubber structure restrains internal resin, reducing splashing damage to surrounding personnel, livestock, or equipment.

  • High Precision & Low Partial Discharge:The vacuum casting process achieves uniform electric field distribution with low partial discharge, enabling precise voltage measurement. Voltage ratio error is controlled within a minimal range, meeting high-precision metering and protection needs to provide reliable voltage data for 36kV and below power systems.

  • Fully Enclosed & Sealed Design:Primary and secondary terminals are completely sealed to prevent dust, moisture, and impurities from invading, avoiding electrical performance degradation caused by external factors. This extends service life and ensures stable operation in complex outdoor environments.

  • Strong Anti-Fouling Capability:The external insulation has high dry arc and large creepage distance, with creepage distance meeting or exceeding relevant standards—especially suitable for high-pollution areas. The surface undergoes special treatment to further enhance anti-fouling performance and reduce flashover risks.

  • Durable Metal Components:All metal components are hot-dip galvanized to enhance corrosion resistance, withstanding long-term outdoor exposure to wind, rain, and sunlight—ensuring reliable long-term service in outdoor environments.

Main technical parameter

  • Rated primary voltage:30 kV or 33 kV or 35 kV etc.

  • Rated secondary voltage:100 V or 110 V

  • Rated power-frequency withstand voltage: 70kV

  • Rated lightning impulse withstand voltage: 170kV

  • Technical standard accords with IEC 60044-2.2003.

  • Other parameters pls see as follow:

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Outline drawing

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a