• JDZ18-12R Voltage Transformer (with fuse)
JDZ18-12R Voltage Transformer (with fuse)
discuss personally
Model
JDZ18-12R-11kV
Basic info
Brand Wone Store
Model NO. JDZ18-12R Voltage Transformer (with fuse)
Rated frequency 50/60Hz
Primary voltage 11kV
Secondary voltage 110V
Series JDZ
Product Detail

Product Overview

JDZ18-12R voltage transformer, epoxy resin casting and full enclosed construction, is used indoor for measuring current, electric energy and protective relaying in single-phase or three-phase AC circuit with the frequency 50Hz or 60Hz and highest voltage for equipment 12kV.

The product has the feature of high reliability, low magnetism of core, large creep distance of external insulation and maintenance free etc.

Key Features

  • Precise Voltage Transformation & Measurement:Specifically designed for 12kV power systems, the JDZ18-12R accurately converts high voltage into low voltage suitable for measurement and protection devices. With minimal voltage ratio error, it meets high-precision metering requirements, providing accurate voltage signals for energy metering devices to ensure precise electricity billing. It also delivers reliable data to relay protection systems, enabling timely detection and response to system anomalies to safeguard grid stability.
  • Built-in Fuse for Overvoltage Protection:This transformer innovatively integrates a fuse to quickly cut off the circuit during voltage surges. When the system encounters lightning strikes or switching overvoltages exceeding safety thresholds, the fuse activates within milliseconds to prevent damage to the transformer and downstream equipment, avoiding severe accidents such as equipment failures and fires, thereby enhancing power system safety and reliability.
  • Epoxy Resin Cast Fully Enclosed Insulation:Utilizing advanced epoxy resin casting technology, it forms a fully enclosed structure with excellent electrical insulation properties capable of withstanding high-voltage impulses. This design effectively resists dust, moisture, salt fog, and other environmental factors, ensuring stable operation in humid coastal areas or dusty industrial environments, reducing maintenance frequency and extending service life.
  • Compliance with International & Industry Standards:Manufactured strictly in accordance with 权威 standards such as IEC 6044 and GB 1207-2006 "Voltage Transformers," it has passed rigorous quality inspections and performance tests including withstand voltage and partial discharge tests. Its quality and performance are fully guaranteed, making it suitable for a wide range of power engineering projects complying with relevant standards.

Main technical parameter

  • Highest voltage for equipment: 12kV
  • Rated primary voltage: 11kV
  • Rated secondary voltage: 100/220V or 110/220V or 100V or 110V.
  • Technical standard accords with IEC 60044-2:2003 Part2 Instrument transformers-Part2: inductive voltage transformers

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

 

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
1. Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In lo
Oliver Watts
07/16/2025
A Quick Verification Method for Low-Voltage Current Transformers
A Quick Verification Method for Low-Voltage Current Transformers
1. Selection of Low - Voltage Current Transformer ConfigurationThere are many factors leading to wrong selection of low - voltage current transformers in civil construction projects. For example, common factors include design problems: the calculated coefficient designed for the load of electrical equipment is relatively large, or the transformation ratio of the current transformer is selected incorrectly. Such a series of reasons will affect the use of electrical equipment. Therefore, in the co
James
07/16/2025
A Quick Verification Method for Low-Voltage Current Transformers
A Quick Verification Method for Low-Voltage Current Transformers
To ensure safe operation of the power system, power equipment operation must be monitored/measured. General devices can’t connect to primary high - voltage equipment directly; instead, large primary currents are scaled down for current transformation, electrical isolation, and use by measurement/protection devices. For AC large - current measurement, conversion to a unified current eases secondary instrument use.Current transformers split into measurement - and protection - type, with accu
Oliver Watts
07/16/2025
Research on Low - Voltage Anti - DC Current Transformer and Detection Device
Research on Low - Voltage Anti - DC Current Transformer and Detection Device
1. Overview of Components and IssuesTA (low-voltage current transformer) and electric energy meters are key components of low-voltage electric energy metering. The load current of such meters is no less than 60A. Electric energy meters vary in type, model, and anti-DC performance, and are connected in series in the metering device. Due to the lack of anti-DC capability, they suffer from metering errors under DC component loads, usually caused by non-linear loads. With the increasing use of DC or
Dyson
07/16/2025
Anti - Theft Device for Low - Voltage Current Transformers
Anti - Theft Device for Low - Voltage Current Transformers
1. Innovation BackgroundWith the progress of society and economic development, the electricity demand of power users is expanding increasingly. Lawbreakers, aiming to save electricity costs and pursue high profits, gradually use high - tech methods to steal electricity, causing huge economic losses to power supply enterprises. Currently, popular electricity theft methods in the market include illegally opening the wiring cover of low - voltage transformers in electric energy metering boxes, alte
Dyson
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!