The FN3 - 12, FN3 - 12R, and FN3 - 12R/S load break switches are high - voltage electrical appliances installed indoors. They are suitable for AC 50Hz, 6kV or 10kV networks to break and close load and overload currents. They can also be used as switches for breaking and closing no - load long lines, no - load transformers, and capacitors. The load break switches with RN3 - type fuses (FN3 - 12R, FN3 - 12R/S) can cut off short circuits and be used as protection switches.This load break switch can be operated with CS3 - type and CS2 - type manual operating mechanisms.

Key Features

  • Multi - scenario Current Control:Suitable for 50Hz, 6kV/10kV AC networks. It can stably break and close load and overload currents, and also support the switching operations of no - load long lines, no - load transformers, and capacitors, covering multiple operation and maintenance scenarios of the distribution network.

  • Extended Short - circuit Protection:After being equipped with an RN3 - type fuse (such as the FN3 - 12R series), it has the ability to cut off short - circuit currents. It can be used as a protection switch to provide short - circuit fault protection for equipment and lines, simplifying the protection configuration of the distribution network.

  • Installation Scenario Adaptation:With an indoor installation design and a compact structure, it is suitable for typical indoor power distribution facilities such as ring main units and box - type substations, meeting the construction and renovation needs of indoor power distribution systems in urban distribution networks, industrial and mining enterprises, etc.

  • Operating Mechanism Compatibility:It supports CS3 and CS2 - type manual operating mechanisms, adapts to different operating habits and existing equipment support systems, reduces the cost of renovation and replacement, and improves the flexibility of on - site operation and maintenance.

  • Mature Technical Architecture:Iterated based on the classic FN3 series, it has stable arc - extinguishing performance, a long mechanical service life, and high long - term operation reliability, reducing the frequency of equipment failures and operation and maintenance workload.

Technical Parameters

Operating Environmental Conditions

  • Altitude: Not exceeding 1000 meters;

  • Ambient air temperature: Not higher than +40°C and not lower than -10°C;

  • Indoor places with air relative humidity not exceeding 90% (when the temperature is +25°C);

  • Environments free from conductive dust;

  • Environments free from corrosive gases that damage metals and insulation;

  • Places without severe vibration and impact;

  • Environments without fire and explosion hazards.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a