• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


High Voltage Current-Limiting Fuse(For full range&transformer protection)

  • High Voltage Current-Limiting Fuse(For full range&transformer protection)
  • High Voltage Current-Limiting Fuse(For full range&transformer protection)

Key attributes

Brand Wone Store
Model NO. High Voltage Current-Limiting Fuse(For full range&transformer protection)
Rated voltage 36kV
Rated normal current 50A
Breaking capacity 40kA
Series Current-Limiting Fuse

Product descriptions from the supplier

Description

Characteristic brief :

  • Rated voltage from 7.2KV to 40.5KV.

  • Wide range of rated current from 6.3A to 200A.

  • Full range performance options available at 12KV and 24KV.

  • Powerful pyrotechnic or spring striker.

  • H.R.C.

  • Gurrent-limiting.

  • Low power dissipation,low temperature rise.

  • Operation extremely quickly,high reliability.

  • With primary coil of transformer in series.

  • Isolating & protecting transformer.

  • Conforming to standards: GB15166.2 DIN43625 BS2692-1 IEC60282-1.

Model illustration:

企业微信截图_17338104044634.png

Technical Parameters:

企业微信截图_17338105507832.png

企业微信截图_17338106475852.png

External&installation dimensions(Unit:tmm)


企业微信截图_17338107374503.png

XRNT Fuse link

企业微信截图_17338107428451.png


XRNT -12KV/ Fuse base

企业微信截图_17338107481513.png

XRNT -40.5KV/ Fuse base

What are the structural features of the high-voltage current-limiting fuses (for the full range and transformer protection)?

Fusible Element Structure:

  • The fusible element is a critical component, typically made from materials with high conductivity and a low melting point, such as silver or copper alloys. Its design is intricate, often featuring multiple narrowed sections that will melt first when subjected to overload or short-circuit currents. This design enables the fuse to respond rapidly to fault currents, effectively limiting the rise in current.

Arc-Quenching Medium and Device:

  • The interior is filled with arc-quenching media such as quartz sand. Quartz sand possesses excellent insulation and thermal conductivity properties. When the fusible element melts and an arc is generated, the quartz sand absorbs the heat from the arc, rapidly cooling and extinguishing it, thereby interrupting the current flow and preventing damage from sustained arcing.

Enclosure Material and Sealing:

  • The enclosure is generally made from high-strength ceramics or composite insulating materials. Ceramic enclosures offer superior insulation performance and mechanical strength, capable of withstanding the pressure generated during internal arc quenching. Additionally, the excellent sealing performance prevents external environmental factors (such as moisture and dust) from affecting the internal arc-quenching medium and the fusible element.


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Intelligent Surge Arrester Monitoring: Trends, Challenges & Future Outlook
    1. Current Status and Shortcomings of Online MonitorsCurrently, online monitors are the most commonly used tools for surge arrester monitoring. While they can detect potential defects, they have significant limitations: manual on - site data recording is required, precluding real - time monitoring; and post - collection data analysis adds to operational complexity. IoT - based intelligent monitoring overcomes these issues—collected data is uploaded via the IoT to processing platforms,
    07/31/2025
  • Surge Arrester Handover & Live Testing Technologies for Reliable Power Grid Operation
    1. Overview of Surge Arrester Handover Test Technology1.1 Necessity of Handover TestThe handover test is a crucial step in ensuring the performance and safe operation of surge arresters within power systems. For power systems with voltage levels at 220 kV and below, surge arresters play a core role in protecting electrical equipment from damage caused by overvoltages and lightning strikes. However, during the process from the arrester leaving the factory to its actual operation after installatio
    07/31/2025
  • Surge Arrester Failure Analysis and Prevention: Key Causes of 10 kV Distribution Arresters' Malfunctions
    1. IntroductionDuring power system operation, main equipment faces threats from internal and atmospheric overvoltages. Surge arresters, especially metal oxide arresters (MOAs) with excellent nonlinear volt - ampere characteristics, are key for protection due to their good performance, large current - carrying capacity, and strong pollution resistance. However, long - term exposure to power frequency voltages, along with component quality, manufacturing processes, and external environments, makes
    07/30/2025
  • Advanced Online Monitoring System for Zinc Oxide Surge Arresters: Key Technologies and Fault Diagnosis
    1 Architecture of the Online Monitoring System for Zinc Oxide Surge ArrestersThe online monitoring system for zinc oxide surge arresters comprises three layers: the station control layer, bay layer, and process layer. Station Control Layer: Includes a monitoring center, a Global Positioning System (GPS) clock, and a B - code clock source. Bay Layer: Consists of online monitoring Intelligent Electronic Devices (IEDs). Process Layer: Features monitoring terminals for Potential Transformers (PTs) a
    07/30/2025
  • Enhancing Surge Arrester Online Monitors: Key Improvements for Precision, Fault Diagnosis, and Reliability
    1 Significance of Surge Arrester Online Monitors1.1 Enhance Power System Safety, Reduce Lightning DamageDuring lightning strikes, surge arresters play a core role in discharging overvoltage. Online monitors ensure arrester stability, detect potential faults in real - time, and trigger alarms for timely intervention—effectively reducing lightning - induced damage to power equipment and systems, and maintaining stable operation.1.2 Real - Time Status Monitoring, Improve Maintenance Effic
    07/30/2025
  • Real-Time Monitoring of Surge Arresters in 10kV GIS Cubicles: Enhancing Railway Power System Safety
    1 Research BackgroundMetal - oxide surge arresters, sealed in cabinets, bear system voltage continuously, risking aging failures, even breakdowns/explosions causing electrical fires. Thus, regular inspection/maintenance is needed. Traditional 3–5 - year - cycle detection (power cut, arrester removal for tests; reinstallation if replaced) poses safety risks and faces space/environment - based standard - grasping difficulties.2 Monitoring Principle of 10kV GIS Cabinet Surge ArresterTo en
    07/30/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.