Electrical Fuse Holders RT18-125-3p Fuse size

  • Electrical Fuse Holders RT18-125-3p Fuse size

Key attributes

Brand Switchgear parts
Model NO. Electrical Fuse Holders RT18-125-3p Fuse size
number of poles 3P
Series RT18-125-

Product descriptions from the supplier

Description

Are all fuse holders the same?

Not all fuse holders are the same. Fuse holders can vary in terms of design, size, current rating, voltage rating, and application. Here are some factors that can differentiate fuse holders:

1.Fuse Type: Fuse holders are designed to accommodate specific types of fuses, such as blade fuses, cartridge fuses, SMD fuses, or plug fuses. The type of fuse holder you need depends on the specific fuse type you are using.

2.Current Rating: Fuse holders have different current ratings to match the maximum current that the fuse can safely handle. It is crucial to select a fuse holder that has a current rating equal to or higher than the maximum expected current in your circuit.

3.Voltage Rating: Fuse holders also have voltage ratings that determine their suitability for different voltage levels. The voltage rating should match or exceed the voltage of your electrical system to ensure proper insulation and safety.

4.Mounting Style: Electrical Fuse Holders can have various mounting styles, such as panel mount, PCB mount, in-line mount, or surface mount. The mounting style should be chosen based on the installation requirements and the available space in your application.

5.Termination Type: Fuse holders may offer different terminal options, such as screw terminals, solder terminals, or quick-connect terminals. The choice of termination type depends on the wiring method and the ease of installation.

6.Application: Fuse holders can be designed for specific applications, such as automotive, industrial, or residential use. Some fuse holders may have additional features to withstand harsh environments, vibrations, or high temperatures, making them suitable for specialized applications.

7.Safety Features: Fuse holders can have additional safety features, such as covers or enclosures to protect against accidental contact or finger-safe designs. These safety features can vary among different fuse holders.

It’s essential to consider these factors and choose a fuse holder that matches the specific requirements of your application, including the type of fuse, current rating, voltage rating, mounting style, and any additional features needed.

Different fuse holders are designed to meet different needs and specifications, so it’s important to select the right one for your application to ensure proper and reliable circuit protection.Item

Multiple low-voltage distribution cabinets suitable for industrial and commercial scenarios, with specific adaptation information as follows: GGD low-voltage fixed switchgear, XL-21 low-voltage power cabinet, GCK low-voltage drawer switchgear, Schneider BlokSeT low-voltage distribution cabinet, etc

No.DN56143

Product model RT18-125
Description Fuse switch disconnector with LEDindicator
Pole 3P
Mounting method DIN rail installation
Wiring method 4-50mm2
Fuse size 22*58
Rated operational current le 125A(500VAC)/100A(690VAC)
Rated operational voltage Ue 500VAC/690VAC
Rated insulation voltage 800V
Rated impulse withstangd current lpk 6KV
Breaking capacity with fuse 100KA(500VAC)/50KA(690VAC)
Utilization category with fuse gG
LED Indicator voltage 110-690VAC/DC
IP IP20
Reference standard IEC 60269-2  GB/T 13539.2
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application