• DS4A  12kV 24kV 40.5kV 72.5kV 126kV 145kV 170kV High voltage disconnect switch
DS4A 12kV 24kV 40.5kV 72.5kV 126kV 145kV 170kV High voltage disconnect switch
discuss personally
Model
DS4A-170/2000-40
DS4A-145D/4000-50
DS4A-145D/3150-50
DS4A-145D/2500-40
DS4A-145D/2000-40
DS4A-145D/1600-40
DS4A-126D/4000-50
DS4A-126D/3150-50
DS4A-126D/2500-40
DS4A-126D/2000-40
DS4A-126D/1600-40
DS4A-72.5D/4000-50
DS4A-72.5D/3150-50
DS4A-72.5D/2500-40
DS4A-72.5D/2000-40
DS4A-72.5D/1600-40
DS4A-72.5D/1250-40
DS4A-40.5D/4000-50
DS4A-40.5D/3150-40
DS4A-40.5D/2500-40
DS4A-40.5D/2000-31.5
DS4A-40.5D/1250-31.5
DS4A-24D/2000-31.5
DS4A-24D/1250-31.5
DS4A-24D/630-31.5
DS4A-12D/2000-31.5
DS4A-12D/1250-31.5
DS4A-12D/630-31.5
Basic info
Brand ROCKWILL
Model NO. DS4A 12kV 24kV 40.5kV 72.5kV 126kV 145kV 170kV High voltage disconnect switch
Rated voltage 170kV
Rated normal current 2000A
Rated frequency 50/60Hz
Rated peak value withstand current 104kA
Rated short-time withstand current 40kA
Series DS4A
Product Detail

Product introduction:

DS4A-12/126/145/170D(W) Switch Disconnector are kinds of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz. It’s used for breaking or connecting HV lines under no loads so that the power lines can be changed and connected and the way the electricity runs is changed. in addition, it can be used to exercise safe electrical insulation for such HV electric apparatuses as bus and breaker.

This product has two insulators with horizontal center breaks. itis openable in the middle and accessible to the grounding switch on one side or two sides. The Switch Disconnector adopts CS14G or CS11 manual operating mechanism or CJ2 motor-based operating mechanism to realize the tri-pole linkage. The earthing switch adopts CS14G manual operating mechanism to realize tri-pole linkage.

In August 2005, this product passed the improvement technology review by State Grid Corporation (Jiangsu provincial branch).

DS4A Switch Disconnector comprises three single poles and operating mechanism. Each pole comprises a base, post insulators and conductive parts. Removable insulating posts are mounted at both sides of a long base, The conducive switch blade's contact arms are respectively fixed at the tops of the insulating posts. When the insulating post at one end of the actuator revolves to drive, with the help of the crossover lever, the reverse rotation of the insulating post at the other end by 90", the conductive switch blade will rotate on the horizontal surface to realize the starting and closing of the isolating switch. A horizontal insulating open break will appear at the opening moment.

Main characteristic:

  • The conductive arm made of rectangular Al-alloy pipes is characterized by high strength, light weight, large radiation area and corruption-resistance.
  • Adopt particular copper alloy to develop the self-contained contact, The contact point is tightened by the elastic force of the contact itself. The contact spring is eliminated to avoid possible drop of the contact in gripping force due to the spring's corrosion and shunting, heating and annealing, possible increment in contact resistance, and possible vicious cycle of the growing heat of the contact. The contact is made of curved copper plate, forming a large connection area with he conductive arm. In the opening and closing processes, there isa short trip of friction between the contact and the finger and he required operating force is small. The conductive part has been acknowledged by the Chinese competent authority as a new and practical patent.(Patent No.. Z103 2 20022.6)
  • The rotating parts of the disconnect switch are designed to be free of any maintenance. The rotating base is designed into a seal structure which denies the access of moisture, dust and harmful gases so that No.2 low-temperature lubricating cream within the bearing will not run off or harden, Within the bearing base are thrust ball bearing and radial ball bearing, both of which will share the gravity and horizontal component of the Switch Disconnector so that the operating torque will not increase after the long-term operation of the disconnect switch.
  • Provide one key sequential control "double confirmation" function expansion.

Main technical parameters:

GW4A-parameters.png

Order notice :

Product model, rated voltage, rated current, rated short-time withstand current and creepage distance must be specified at the goods ordering time;

The disconnect switch offers several options of grounding (no, left. right. both left and right). Unless otherwise specified, the goods supplied will be considered as proving the option of right grounding;

Notes:

  • The methods of Judging left and right grounding: hold out both arms and keep the arms In the same direction as the Switch Disconnector is open的The earthing switch will be considered as left grounding if on the left hand side, and right grounding if on the right hand side;
  • The actuator's model and name, voltage and the number of contacts for auxiliary switch;
  • Specify the type of power and voltage degree for the electromagnetic lock of the actuator.

 

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!