• DS16 126kV 252kV 363kV 420kV 550kV High voltage disconnect switch
DS16 126kV 252kV 363kV 420kV 550kV High voltage disconnect switch
discuss personally
Model
DS16B-550/4000-63
DS16B-550/3150-50
DS16B-420/3150-50
DS16B-363/5000-63
DS16B-363/3150-50
DS16B-252/5000-63
DS16B-252/3150-50
DS16B-126/3150-40
DS16B-126/2500-40
Basic info
Brand ROCKWILL
Model NO. DS16 126kV 252kV 363kV 420kV 550kV High voltage disconnect switch
Rated voltage 126kV
Rated normal current 2500A
Series DS16
Product Detail

Description:

DS16 series disconnector adopts single-column single-arm vertical telescopic structure, which is mainly composed of base, insulator, conductive system, operating mechanism, etc. The disconnector is operated by CJ11 motor operating mechanism for opening and closing. The attached ground switch is mainly composed of ground switch system and operating mechanism, and each group of ground switches is operated by a CJ11 motor operating mechanism for opening and closing.


Main Features:

 

  •  Simple and compact structure, small footprint.

  • Strong product flow capacity, long mechanical life.

  • Optimized spring design, light and smooth operation.

  •  High seismic performance, can resist nine degrees of earthquake intensity.

  • The layout is flexible, convenient for users to choose.

Technical parameter

 

image.png

 

What are the operation modes of the disconnector?

Operation Methods:

  • Manual: Manual isolator switches are simple to operate and cost-effective. They are suitable for applications where operations are infrequent, speed is not critical, and operators can easily access the site.

  • Electric: Electric isolator switches are ideal for large substations and environments that require a high degree of automation. They enable remote control and automated operations but come with higher costs and the need for a stable power supply and complex control systems.

  • Pneumatic: Pneumatic isolator switches offer rapid and powerful operation, making them suitable for applications requiring high-speed operation and explosion-proof environments (such as chemical plants and refineries). However, they require a compressed air system.

Operation Frequency:

If the isolator switch needs to be operated frequently, it is important to consider its mechanical life and the reliability of the operating mechanism. For example, in substations where frequent switching operations are required, it is advisable to select isolator switches with long mechanical life and reliable, flexible operating mechanisms to reduce maintenance costs and the incidence of failures.

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of the Principle of Second - harmonic Restraint for Overcurrent Protection of Distribution Automation Switches
Analysis of the Principle of Second - harmonic Restraint for Overcurrent Protection of Distribution Automation Switches
Substance of Second - harmonic Restraint in Overcurrent ProtectionThe substance of second - harmonic restraint in overcurrent protection is to use the second - harmonic component to judge whether the current is a fault current or an excitation inrush current. When the percentage of the second - harmonic component to the fundamental - wave component is greater than a certain value, it is judged to be caused by the excitation inrush current, and the overcurrent protection is blocked.Therefore, the
Leon
07/18/2025
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In low
Felix Spark
07/18/2025
What are the typical connection methods for 35kV distribution lines?
What are the typical connection methods for 35kV distribution lines?
Typical Wiring Diagram of 35kV Line Radial π ConnectionWhen a 35kV line adopts a radial power grid structure, a single - side power supply or a double - side power supply radial type can be used according to the situation of the power supply points, and a loop - out interval is reserved at the end of the line.Typical Wiring Diagram of 35kV Line Radial T - ConnectionFor double - radial lines, it is advisable to select a double - side power supply. When the power supply points do not meet the r
Leon
07/18/2025
Why are the ground fault point and the accident point not at the same location?
Why are the ground fault point and the accident point not at the same location?
Fault Transfer VoltageIn low - voltage distribution systems, there is a type of personal electric shock accident where the accident occurrence point and the system fault point are not at the same location. This kind of accident occurs because after a ground fault happens elsewhere, the generated fault voltage is conducted to the metal casings of other equipment through the PE wire or PEN wire. When the fault voltage on the metal casing of the equipment is higher than the human - body safe voltag
Leon
07/18/2025
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!