• Complete Set of Electric Brake Switch for 120kA Hydro-turbine Generating Units
Complete Set of Electric Brake Switch for 120kA Hydro-turbine Generating Units
discuss personally
Model
ZHN10-24 /15000-100
Basic info
Brand ROCKWILL
Model NO. Complete Set of Electric Brake Switch for 120kA Hydro-turbine Generating Units
Rated voltage 24kV
Rated normal current 15000
Series Circuit Breaker
Product Detail

Description:

This product is an essential switch equipment for achieving rapid shutdown of large hydroelectric generators. In 2019, it was appraised by the National Energy Administration and its comprehensive technical performance is at the leading domestic and international level. Currently, it has supplied 28 products to the Wudongde and Baihetan hydropower stations.

Product Performance:

  • High braking performance parameters: it has the capacity of braking current 30,000A and braking time 50 minutes.

  • High mechanical reliability: the brake switch and earthing switch can meet the mechanical life requirements of operation for 10,000 times.

  • Strong making capacity: the brake switch successfully passed the load current breaking and making test, and the current is 28,000A.

  • Reliable safety protection measures: pressure release device is installed at the top of the brake switch. When the gas pressure in the arc extinguishing chamber exceeds 1.2 MPa due to an accident, the gas will be released to ensure the safety of the personnel and surrounding equipment, The product design can ensure the stable operation of the power plant.

Product Structure:
微信图片_20240615104853_修复后.png

  • Product consists of three single poles, and each pole has an individual enclosed metal enclosure mounted on the same chassis.

  • Brake switch is equipped with hydraulic spring operating mechanism; earthing switch is equipped with a motor operating mechanism; the driving modes are all three-phase mechanical linkage.

  • The main circuit adopts natural cooling.

  • Each operating mechanism is installed on the side of the product close to the control cabinet.

  • SF6 is used as insulation and arc-extinguishing medium for brake switch, The arc-striking contact adopts ablation-resistant copper-tungsten material, which effectively improves the reliability and electrical life of the brake switch.

  • The earthing switch takes air as insulation medium, the fixed contact is installed on the support of the main circuit, the moving side is installed on the bottom plate of the box body, and the moving contact is connected with the single phase enclosure and forms the earthing circuit through the closed bus bar connected with the moving contact.

  • The overall structure of brake switch is compact and convenient for installation and maintenance on site.

Typical applications:
微信图片_20240615104935_修复后.png
微信图片_20240615104912_修复后.png
 Main technical parameters:

image.png

What is the standard for the opening time and opening time of the generator circuit breaker?

The opening and closing times for generator circuit breakers do not have a single fixed standard. The specific standards vary depending on the type of circuit breaker, voltage level, application scenario, and relevant standards and regulations. Below is a detailed introduction to the relevant standards:

Closing Time (Making Time):

  • Standard Range: Generally, the closing time for generator circuit breakers is typically between a few tens of milliseconds to over one hundred milliseconds. For example, common medium-voltage generator circuit breakers may have a closing time in the range of 30ms to 80ms, while high-voltage, high-capacity generator circuit breakers may have slightly longer closing times, but generally within 100ms.

  • Relevant Standards: According to relevant standards, the three-phase asynchronism closing time for generator circuit breakers should not exceed 5ms.

Opening Time (Breaking Time):

  • Standard Range: The opening time is the sum of the closing time and the arc burning time. The value can vary based on multiple factors. Generally, for medium-voltage generator circuit breakers, the opening time may be around 50ms to 150ms, while for high-voltage, high-capacity generator circuit breakers, the opening time may be around 100ms to 250ms.

  • Relevant Standards: For different voltage levels and types of generator circuit breakers, the transient recovery voltage during the interruption of short-circuit currents, load currents, and out-of-step currents should meet the corresponding standard requirements. The first-pole factor and magnitude factor can be taken as 1.5.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!