625-650 Watt bifacial module with dual glass

  • 625-650 Watt bifacial module with dual glass

Key attributes

Brand Wone
Model NO. 78HL4-BDV 625-650 Watt BIFACIAL MODULE WITH DUAL GLASS
Maximum Power 635Wp
Series 78HL4-BDV

Product descriptions from the supplier

Description

Certification

  • IEC61215:2021 / IEC61730:2023 ·

  •  IEC61701 / IEC62716 / IEC60068 / IEC62804 · 

  • ISO9001:2015: Quality Management System · 

  • ISO14001:2015: Environment Management System ·

  •  ISO45001:2018: Occupational health and safety management systems.

Features

  • N-type modules with Tunnel Oxide Passivating Contacts (TOPcon) technology offer lower LID/LeTID degradation and better low light performance.

  • N-type modules with JinkoSolar's HOT 3.0 technology offer better reliability and efficiency.

  • Dual-sided power generation gain increases with backside exposure to light, significantly reducing LCOE.

  • Certified to withstand: 5400 Pa front side max static test load 2400 Pa rear side max static test load.

  • Better light trapping and current collection to improve module power output and reliability.

  • Minimizes the chance of degradation caused by PID phenomena through optimization of cell production technology and material control.

image.png


Mechanical Characteristics

image.png

Packaging Configuration

image.png

Specifications (STC)

image.png

Specifications (BNPI)

image.png

Application Conditions

image.png

Engineering Drawings

image.png

*Note: For specific dimensions and tolerance ranges, please refer to the corresponding detailed module drawings.

Electrical Performance & Temperature Dependence

image.png

image.png

What is a solar bifacial module?

Solar bifacial modules are solar panels capable of absorbing light from both sides (that is, the front and the back) and converting it into electrical energy. Compared to traditional monofacial solar modules, bifacial modules have a higher potential for energy output, as they can not only capture the sunlight directly shining on them but also absorb light reflected from the ground as well as scattered light from the surroundings.

Working Principle of Bifacial Modules:

  • Front Side Absorption: The front side works like traditional solar modules, absorbing direct sunlight through the solar cells and converting it into electrical energy.

  • Back Side Absorption: The back side is also covered with a layer of solar cells that can absorb sunlight reflected from the ground as well as scattered light from the surroundings.

  • Light Trapping: The reflectivity of the ground affects the power generation efficiency of the back side of bifacial modules. Ground surfaces that are white or light in color have higher reflectivity, providing more reflected light to the solar cells on the back side.

  • Environmental Impact: The installation environment can also affect the performance of bifacial modules. For example, different surfaces such as grasslands, snow-covered areas, or rooftops will have varying levels of reflectivity and amounts of scattered light.



Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 65666m²m² Total staff: 300+ Highest Annual Export(usD): 50000000
Workplace: 65666m²m²
Total staff: 300+
Highest Annual Export(usD): 50000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.