• 60kW-180kW AC/DC Integrated EV Charger
60kW-180kW AC/DC Integrated EV Charger
discuss personally
Model
WZ-180kW
WZ-120kW
WZ-60kW
Basic info
Brand RW Energy
Model NO. 60kW-180kW AC/DC Integrated EV Charger
Rated frequency 50/60Hz
Rated Output Rating 180kW
Series DC EV Chargers
Product Detail

Product Overview

 60-180kW EV charger supports all major standards with 95%+ efficiency and OCPP 1.6 compliance.60kW-180kW AC/DC integrated EV charging station, designed for fast, reliable, and flexible electric vehicle charging. As a R&D-driven high-tech enterprise, Rockwill specializes in power automation and new energy EV solutions, collaborating with Chongqing Semiconductor High-tech Institute to deliver green, low-carbon, and eco-friendly charging infrastructure.This advanced charging station supports multi-standard compatibility (CHAdeMO, GB/T, CCS1, CCS2, Type 2 AC) and offers customizable solutions for global partners, including OEM, component supply, and turnkey charging systems.

Key Features:

  • Ultra-Fast Charging:Charges EVs up to 80% in just 30 minutes

  • Multi-Standard Support:Compatible with CHAdeMO, GB/T 20234, CCS1, CCS2, and Type 2 AC

  • High Efficiency>95% efficiency at nominal power with PF>0.99 (APFC)

  • Smart ConnectivityOCPP 1.6 JSON, RFID card reader (ISO14443A), and 7” touchscreen HMI

  • Multi-Language & Remote Management:Supports English, French, Spanish, Russian + Ethernet/4G/3G

  • Robust & Weatherproof:IK10 impact resistance & IP54 protection for durability

  • Easy Installation & Maintenance:Modular design for quick deployment

Product Advantages:

  • Global Compatibility:Works with major EV standards, ideal for diverse markets

  • Energy-Efficient:High power factor (APFC) reduces grid strain & operational costs

  • Future-Ready:OCPP 1.6 ensures seamless integration with charging networks

  • User-Friendly:Intuitive touchscreen, RFID authentication, and multilingual support

  • Reliable & Durable:Built for harsh environments with IK10/IP54 protection

Technical data:

Application Scenarios:

  • Public Charging Stations:Highways, shopping malls, parking lots

  • Fleet & Commercial Charging;Logistics hubs, taxi/bus depots

  • Smart Cities & Municipal Projects;Government-backed EV infrastructure

  • Private Enterprises:Hotels, office buildings, and retail centers

  • Custom Solutions:OEM partnerships & white-label manufacturing

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!