• 6 - 220kV Post - type Composite - Housed Metal Oxide Surge Arresters
6 - 220kV Post - type Composite - Housed Metal Oxide Surge Arresters
discuss personally
Model
YH10WZ-200/520
Basic info
Brand ROCKWILL
Model NO. 6 - 220kV Post - type Composite - Housed Metal Oxide Surge Arresters
Rated voltage 200kV
Rated frequency 50/60Hz
Series YH5WS
Product Detail

Description

6 - 220kV Post - type Composite - Housed Metal Oxide Surge Arresters are specialized protective devices engineered for medium - to - high voltage power systems (spanning 6kV to 220kV). Structured as vertical post - type units with composite (typically silicone rubber) housings, they integrate metal oxide varistor (MOV) technology. Installed in substations, distribution networks, and alongside key equipment like transformers and circuit breakers, these arresters suppress overvoltages from lightning, switching operations, or system faults. By clamping surge voltages and diverting excess currents to the ground, they safeguard power system integrity, ensuring stable operation and preventing equipment damage across 6 - 220kV grids.

Features

  • Wide Voltage Range Compatibility:Covers 6kV to 220kV systems, with rated voltages precisely matched to diverse medium - high voltage grid needs. Adapts to both distribution and sub - transmission networks, providing uniform surge protection across multiple voltage classes.

  • Composite Housing Advantages:The composite (silicone rubber) enclosure offers superior performance: excellent hydrophobicity resists pollution and moisture, reducing flashover risks; high mechanical strength withstands wind, seismic forces, and thermal cycles; lightweight design simplifies installation vs. traditional porcelain, cutting labor and transport costs.

  • Post - type Structural Design:Vertical post - type layout enables space - efficient installation in substations, aligning with standard insulator/post mounting configurations. Simplifies integration into existing grid setups, reducing spatial requirements and facilitating maintenance access.

  • Low Maintenance & Long Lifespan:Composite housing resists aging, UV degradation, and chemical corrosion, lowering maintenance frequency. Built - in thermal stability and MOV self - healing properties (to an extent) extend service life, ensuring reliable protection for 15 + years with minimal upkeep.

  • Compliance & Safety:Meets international standards (e.g., IEC 60099 - 4, IEEE C62.11) for surge arresters. Undergoes rigorous testing for impulse current withstand, thermal stability, and environmental endurance, guaranteeing safe operation in harsh grid conditions.

  • Surge Current Diversion Efficiency:Effectively diverts large surge currents (from lightning/switching) to the ground, limiting overvoltages to levels safe for connected equipment (transformers, cables). Reduces downtime risks and equipment damage, enhancing overall grid resilience.

parameters

Model 

Arrester

System

Arrester Continuous Operation

DC 1mA

Switching Impulse

Nominal Impulse

Steep - Front Impulse

2ms Square Wave

Nominal

Rated Voltage

Nominal Voltage

Operating Voltage

Reference Voltage

Switching Impulse Voltage Residual

Nominal Impulse Voltage Residual

Steep - Front Impulse Current Residual

Current - Withstand Capacity

Creepage Distance

kV

kV

kV

kV

kV

kV

kV

A

mm

(RMS Value)

(RMS Value)

(RMS Value)

Not Less Than

Not Greater Than

Not Greater Than

Not Greater Than

20 Times






(Peak Value)

(Peak Value)

(Peak Value)

(Peak Value)


YH5WS-10/30

10

6

8

15

25.6

30

34.6

200

380

YH5WS-12/35.8

12

6

9.6

18

30.6

35.8

41.2

200

380

YH5WS-15/45.6

15

10

12

23

39

45.6

52.5

200

380

YH5WS-17/50

17

10

13.6

25

42.5

50

57.5

200

380

YH5WR-51/134

51

35

40.8

73

105

134

154

400

1350

YH5WZ-12/32.4

12

10

9.6

17.4

27.6

32.4

37.2

200

380

YH5WZ-15/40.5

15

10

12

21.8

34.5

40.5

46.5

200

380

YH5WZ-17/45

17

10

13.6

24

38.3

45

51.8

200

380

YH5WZ-51/134

51

35

40.8

73

114

134

154

400

1350

YH5WZ-84/221

84

66

67.2

121

188

221

251

600

2280

YH5WZ-90/235

90

66

72.5

130

201

235

270

600

2280

YH5WZ-96/250

96

66

75

140

213

250

288

600

2280

YHY5WZ-100/260

100

110

78

145

221

260

291

600

2280

YH10W1-100/260

100

110

78

145

221

260

291

600

3906

YH10WZ-90/235

90

110

72.5

130

201

235

264

800

3150

YH10WZ-96/250

96

110

75

140

213

250

280

800

3150

YH10WZ-100/260

100

110

78

145

221

260

299

800

3150

YH10WZ-102/266

102

110

79.6

148

226

266

297

800

3150

YH10WZ-108/281

108

110

84

157

239

281

315

800

3150

YH10W1-100/260

100

110

78

145

221

260

291

800

3906

YH10WZ-192/500

192

220

150

280

426

500

560

800

6300

YH10WZ-200/520

200

220

156

290

442

520

582

800

6300

YH10WZ-204/532

204

220

159

296

452

532

594

800

6300

YH10WZ-216/562

216

220

168.5

314

478

562

630

800

6300

YH10W1-200/520

200

220

156

290

442

520

582

600

7812

YH10W1-200/520

200

220

156

290

442

520

582

800

7812

YH1.5W-60/144

60

110

48

85

135

144


400

2280

YH1.5W-72/186

72

110

58

103

174

186


400

2280

YH1.5W-144/320

144

220

116

205

299

320


400

3530

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!