380V/400V/415V/480V/6.3kV/10.5kV Chinese Yuchai series alternators

  • 380V/400V/415V/480V/6.3kV/10.5kV Chinese Yuchai series alternators

Key attributes

Brand Wone
Model NO. PAUWAY - Chinese Yuchai series alternators
Prime power 20KW
Reserve power 22KW
Series Yuchai

Product descriptions from the supplier

Description

Description:

The PWY Series - uses Chinese Yuchai brand engines with the option of EVOTEC, Marathon or Leroy-Somer alternators.

Voltage optional: 380V/400V/415V/480V/6.3kV/10.5kV (special voltage can be customized)

If you choose the 60HZ model, please contact us directly. we will provide you with the 60HZ model according to your requirements.

Technical parameters:

image.png

image.png

image.png

Remark:

  • All ratings are for reference only, please refer to the specific generator set technical data sheet for final power ratings.

  • All rating data are based on ISO 8528-1, 1SO 3046, DIN6271 operating under conditions using typical fan sizes and gear ratios. PAUWAY quotes a performance tolerance of ±5%.

  • Prime power = power under available load instead of the main grid. 10% overload is allowed for one hour of operation every 12 hours.

  • Standby power = power available under variable load in the event of a failure in the main grid, up to 500 hours per year. Overload is not allowed.

  • Rated power factor: 0.80.

  • N/A: Not available.

  •  We reserves the right to change models, technical specifications, colors, configurations and accessories without prior notice. Please contact our sales team before ordering.

What are the characteristics of Yuchai series alternators?

Advanced Technology:

  • Utilizing technology from AVL, a leading European company, the engine features an integrated forged steel crankshaft and alloy cast iron cylinder heads. These components contribute to a compact design with reduced weight, minimal vibration, low noise levels, and high reliability.

Complete Combustion:

  • Employing four-valve technology and P-type fuel injectors, the engine achieves excellent fuel atomization, ensuring thorough combustion. This improves fuel efficiency, reduces fuel consumption, and lowers emissions.

Excellent Sealing Performance:

  • Proprietary piston ring sealing technology and valve oil seals significantly reduce lubricating oil consumption by 30% compared to similar domestic products in the same power class. This results in lower operating costs and reduced maintenance frequency.

Stable Speed Regulation:

  • The speed regulation system is equipped with electronic governor mechanisms, ensuring stable engine operation under varying loads. This provides consistent output voltage and frequency, better meeting the requirements of various electrical devices.


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 65666m²m² Total staff: 300+ Highest Annual Export(usD): 50000000
Workplace: 65666m²m²
Total staff: 300+
Highest Annual Export(usD): 50000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • In-Depth Analysis of Fault Protection Mechanisms for Generator Circuit Breakers
    1.Introduction1.1 Basic Function and Background of GCBThe Generator Circuit Breaker (GCB), as the critical node connecting the generator to the step-up transformer, is responsible for interrupting current under both normal and fault conditions. Unlike conventional substation circuit breakers, the GCB directly withstands the massive short-circuit current from the generator, with rated short-circuit breaking currents reaching hundreds of kiloamperes. In large generating units, the reliable operati
    11/27/2025
  • Research and Practice of Intelligent Monitoring System for Generator Circuit Breaker
    The generator circuit breaker is a critical component in power systems, and its reliability directly affects the stable operation of the entire power system. Through research and practical application of intelligent monitoring systems, the real-time operational status of circuit breakers can be monitored, enabling early detection of potential faults and risks, thereby enhancing the overall reliability of the power system.Traditional circuit breaker maintenance primarily relies on periodic inspec
    11/27/2025
  • Why Install GCB at Generator Outlets? 6 Core Benefits for Power Plant Operations
    1.Protects the GeneratorWhen asymmetric short circuits occur at the generator outlet or the unit bears unbalanced loads, the GCB can quickly isolate the fault to prevent generator damage. During unbalanced load operation, or internal/external asymmetric short circuits, twice the power frequency eddy current is induced on the rotor surface, causing additional heating in the rotor. Meanwhile, the alternating electromagnetic torque at twice the power frequency induces double-frequency vibration in
    11/27/2025
  • Silent Diesel Generator Installation Guide: Key Steps & Critical Details for Efficiency
    In industrial production, emergency rescue, commercial buildings, and other scenarios, silent-canopy diesel generator sets serve as the “core backup” for stable power supply. The quality of on-site installation directly determines the unit’s operational efficiency, noise control performance, and service life; even minor oversights may lead to potential faults. Today, based on practical experience, we outline the complete standardized procedures and critical details for on-site installation of si
    11/27/2025
  • What safety features should pumps in power generation have?
    Safety Features of Pumps Used in Power GenerationPumps used in power generation, particularly in thermal power plants, nuclear power stations, and other types of power facilities, must possess a range of stringent safety features to ensure their reliability and safety. These pumps are typically employed in critical systems such as circulating water systems, cooling systems, feedwater systems, etc., making their safety paramount. Below are the key safety features that pumps used in power generati
    12/06/2024
  • Is it possible to combine two generators to increase their power?
    Is It Possible to Combine Two Generators to Increase Their Power Output?Combining two generators to increase the total power output is feasible, but it requires meeting certain conditions and implementing appropriate measures. This practice in power systems is known as parallel operation or paralleling. By operating multiple generators in parallel, they can collectively supply power to larger loads, thereby providing a higher total output. However, parallel operation is not a simple physical con
    12/04/2024
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.