• 380V/400V/415V/480V/6.3kV/10.5kV SME series diesel alternators
380V/400V/415V/480V/6.3kV/10.5kV SME series diesel alternators
discuss personally
Model
FD-1200D-1320
FD-1100D-1200
FD-1000D-1100
FD-800D-880
FD-600D-660
FD-550D-600
Basic info
Brand Wone
Model NO. PAUWAY-SME series alternators
Prime power 1200KW
Reserve power 1320KW
Series SME
Product Detail

Description:

Diesel generator set type spectrum.

The PWS Series - uses SME brand engines from a joint venture between China and Mitsubishi, with the option of Stamford, Marathon or Leroy-Somer alternators.

Voltage optional: 380V/400V/415V/480V/6.3kV/10.5kV (special voltage can be customized).

Technical parameters:

image.png

Remark:

  • All ratings are for reference only, please refer to the specific generator set technical data sheet for final power ratings.

  • All rating data are based on ISO 8528-1, 1SO 3046, DIN6271 operating under conditions using typical fan sizes and gear ratios. PAUWAY quotes a performance tolerance of ±5%.

  • Prime power = power under available load instead of the main grid. 10% overload is allowed for one hour of operation every 12 hours.

  • Standby power = power available under variable load in the event of a failure in the main grid, up to 500 hours per year. Overload is not allowed.

  • Rated power factor: 0.80.

  • N/A: Not available.

  • We reserves the right to change models, technical specifications, colors, configurations and accessories without prior notice. Please contact our sales team before ordering.


What is Fuel Injection Technology?

Working Principle:

Taking the electronic control gasoline injection system as an example, the electric fuel pump is installed inside the fuel tank. It draws fuel from the tank and pressurizes it. The pressurized fuel then passes through a fuel filter to remove impurities before being delivered to the distributor pipe located above the engine. The distributor pipe connects to injectors mounted on the intake manifold of each cylinder.

The injector is essentially an electromagnetic valve controlled by the computer (Electronic Control Unit, ECU). Based on signals from sensors such as the air flow sensor and crankshaft position sensor, the ECU calculates the engine's air intake volume and speed, determining the basic fuel injection quantity accordingly. It further adjusts the fuel injection quantity based on operating parameters like throttle opening, engine coolant temperature, and intake air temperature. The ECU controls the duration of each fuel injection cycle to regulate the amount of fuel injected, ensuring that the fuel is sprayed in a fine mist into the intake manifold where it mixes with air and is drawn into the cylinders during the intake stroke.

Advantages:

Improved Fuel Economy:

  • Precise Fuel Injection Control: By accurately controlling the fuel injection quantity, it ensures complete combustion of fuel, reducing waste and lowering fuel consumption.

Enhanced Power Performance:

  • Optimized Fuel Injection for Various Conditions: The system can promptly adjust the fuel injection quantity and timing according to different engine conditions (e.g., idle, acceleration, high-speed driving), optimizing the air-fuel mixture concentration. This improves the engine's output power and torque, enhancing acceleration performance.

Reduced Exhaust Emissions:

  • Complete Combustion: Precise fuel injection control promotes more thorough combustion, reducing emissions of harmful gases such as carbon monoxide, hydrocarbons, and nitrogen oxides, thus meeting increasingly stringent environmental standards.



Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!