• 36/38kV Indoor vacuum circuit breaker with servomotor actuation and controlled switching
36/38kV Indoor vacuum circuit breaker with servomotor actuation and controlled switching
discuss personally
Model
VD4-AF-38-2500
Basic info
Brand ABB
Model NO. 36/38kV Indoor vacuum circuit breaker with servomotor actuation and controlled switching
Rated voltage 38kV
Rated normal current 2500A
Rated frequency 50/60Hz
Series VD4-AF1
Product Detail

Description:

 ABB offers its new vacuum circuit breaker with servomotor actuation and controlled switching technology up to 38kV, 2500A, 31.5kA and up to 150,000 operations with extremely low inrush, to support your business needs for diverse installations like steel industries applications.

Feature:

 Protect your assets 
•    Enables increased lifespan of transformers by more than 10% in e.g. 3 years 
•    Reduction of hazards due to improved protection range 
•    Up to 5-to-10-times higher endurance performance than the market standard

Maximize your output 
•    Reduced total cost due to elimination of downtime for breaker overhaul and a lifespan 5 times the market standard, with predictive health indication 
•    Reduced compensation losses up to 10% while increasing power quality 
•    Fast and reliable support thanks to ABB’s global footprint

 Optimize your investment  

  • Elimination of inrush limiting reactors and resistances, leading to significant cost and space savings 

  • Cost saving by as much as 20%, using same ratings, same interfaces of existing MV substation thanks to optimized footprint equivalent to standard distribution breakers

 Technical Characteristics:

Type tested according to IEC 62271-100

Technical Characteristics of sensor  :

Type tested according to IEC 60044-7

 

Know your supplier
ABB
As an authorized distributor of ABB products, we take great pride in our partnership.
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Business Type
Sales
Highest Annual Export (USD)
$580000000
Professional Experience
11 years
Workplace
20000m²
占位
占位
Documents
Public.
36/38kV vacuum circuit breaker with servomotor actuation and controlled switching
Manual English
PDF
FAQ
Q: What are the precautions for installing indoor vacuum circuit breakers?
A:
Ensure the installation environment is dry, free of corrosive gases, and well-ventilated (meeting the IP4X protection class requirements). Check that the dimensions of the switchgear cabinet match those of the circuit breaker (e.g., withdrawable types need to be compatible with the switchgear rails), and fasten the connection terminals securely to prevent loosening and overheating. The insulation distance of the primary circuit must meet the standards (e.g., for 12kV products, the phase-to-phase and phase-to-ground clearances shall be ≥125mm).
Q: What are the differences between indoor vacuum circuit breakers and SF₆ circuit breakers?
A:
Arc-quenching medium: Vacuum circuit breakers use vacuum for arc quenching (environmentally friendly, no greenhouse gases), while SF₆ circuit breakers use SF₆ gas (requiring attention to gas leakage and environmental treatment). Volume and maintenance: Vacuum circuit breakers are smaller in size and have a longer maintenance cycle (the maintenance-free cycle can reach 10 years); SF₆ circuit breakers require regular detection of gas pressure.
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download