• 252kV HV Gas Insulated Switchgear (GIS)
252kV HV Gas Insulated Switchgear (GIS)
discuss personally
Model
ZF28-252/3150-50
Basic info
Brand ROCKWILL
Model NO. 252KV SF6 Gas-insulated GIS high voltage switchgear
Rated voltage 252kV
Rated normal current 3150A
Series ZF28
Product Detail

Product Overview:

 ZF28-252 type GIS is composed of standard modules through flanged joint, which can meet the demand for substation optimization design through the flexible combination between modules. It saves space and conforms to technical requests.
This product can be applied to power system, power generation, rail transportation, petrochemical, metallurgy, mining, building materials and other large industrial consumer.

Features:

  •  Special arc extinguish chamber design with spring operation mechanism.

  •  The structure is tight and the minimum interval width can reach 1670mm.

  •  Three phase encapsulated main bus-bar and 3- position disconnector and earthing switch.

  • Self- researched 3-position disconnector and earthing switch.

  • Completely self-research and development with high starting point and large investment.

  •  Inspected to be qualified by KEMA.

  •  High level of parameters, advanced structural design.

  •  Insulation level is higher than IEC and GB standards.

  • Self-blast combined interrupter, 3- position disconnector and earthing switch, spring operating mechanism.

  •  Double sealing ring structure.

  • Minimum area; Compact and standardized module design with minimum intervals width 1670mm.

  •  It is applied to cold, humid, salt fog, coastal, high altitude areas.

  • Spring operating mechanism base.

Technical Parameters:

ZF28-252 GIS .png

What are the basic principles of GIS operation ?

  • Under normal circumstances, the circuit breaker and disconnector of GIS equipment are mainly operated remotely, and the "remote/local" opening of the circuit breaker and disconnector is concerned about the "remote" position.

  • The grounding switch of GIS equipment can only be operated on the spot, and the knife will be opened "remote/local" and concerned about the "local" during operation.

  • In any case, only the program can be operated, and the "interlock release switch" on the control cabinet must be in the "interlocking" position, and the unlocking key is sealed together with the microcomputer anti-mistaken unlocking key, and is used according to the same regulations.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
×